Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in September 2026.
The most recent job was on September 16, 2026.
Responded to service call for mini-split system experiencing operational issues. Replaced control board under manufacturer warranty and contacted technical support to obtain proper DIP switch configuration for the new board, as settings differed from original unit. Upon testing, compressor cycled on briefly then shut down. Verified standing refrigerant pressures were within normal range for ambient conditions. Performed diagnostic testing on condenser fan motor with technical support guidance, revealing unstable resistance readings indicating motor failure. Determined that additional condenser fan motor replacement and second control board will be required to restore system operation. Completed scheduled furnace maintenance during same visit. Tested temperature sensors and confirmed proper operation. Inspected air filter and found it clean. Cleared condensate drain line to ensure proper drainage. Inspected and verified flame sensor and igniter condition. Checked blower compartment an
Responded to concerns regarding slow-draining shower, odorous floor drains, and potential sewer backup issues. Performed video camera inspection of main sewer line and removed shower drain cap to visually inspect the P-trap, finding both clear of obstructions. Determined that the slow drainage may be attributed to an underground venting issue rather than a blockage in the drainage system.
Completed comprehensive furnace and air conditioning maintenance tune-up on multiple HVAC units. Performed full furnace inspection including cleaning flame sensor, verifying proper condensate drainage, checking blower motor speeds, and inspecting heat exchanger with no issues found. Confirmed gas pressure within specifications and burners operating cleanly. System startup verified with 50° temperature rise across heat exchanger, indicating proper operation. Proceeded to air conditioning unit where electrical components were inspected and tested. Removed access panels and flushed condenser coils to remove debris and buildup, restoring optimal heat transfer efficiency. Verified evaporator drain line flowing freely with no blockages. Air conditioning system tested with 19° temperature drop across evaporator coil, confirming proper refrigerant charge and system performance. Additionally adjusted temperature setting on recently installed water heater per occupant request. All systems operat
Installed flexible gas line up to 10 feet with two fittings to supply new stove location. Drilled access point through kitchen floor at appliance alcove and installed gas-tight floor bracket with fitting. Accessed basement area below and tapped into existing gas supply line, running new branch line vertically through floor to terminate at kitchen level. Secured all connections with proper fittings and brackets. Pressurized the gas system and performed leak detection testing on all new joints and fittings—no leaks detected. System passed pressure test successfully. Shut off gas supply at isolation valve and capped the terminal end of the new gas line. Installation is ready for appliance connection by stove installer, who will remove cap and complete final hookup to appliance.
Completed scheduled heating system maintenance and tune-up on Carrier furnace model 59SC2. Upon inspection, discovered seized inducer motor which was manually freed to restore operation, though motor will require replacement in near future. Found improperly installed air filter causing restricted airflow and system shutdown; replaced filter to restore proper airflow and operation. Measured gas pressures using Testo 310 II combustion analyzer and found inlet pressure below manufacturer specifications; adjusted gas valve to bring pressure within acceptable range. Performed complete safety and efficiency assessment of heating system. System operational at time of departure but recommend scheduling inducer motor replacement to prevent future failure.
Responded to warranty call for refrigerant leak on recently replaced condensing unit. Recovered refrigerant from system and performed comprehensive pressure testing at 600 PSI with nitrogen for one hour with zero pressure drop, confirming no leaks in condenser coil or primary refrigerant circuit. Suspect leak originating from location other than outdoor unit based on testing results. Pressurized system to maximum capacity with available nitrogen supply and injected UV dye into refrigerant circuit to facilitate leak detection during extended runtime. Disconnected electrical power at breaker and disconnect switch per safety protocol, leaving system pressurized for leak identification. System requires substantial operating hours for UV dye to circulate and pinpoint leak location during follow-up inspection.
Responded to callback regarding electrical grounding issue discovered during previous water softener and RO system installation. Upon inspection, confirmed that ground bonding lines for gas piping were disconnected and not reconnected during the initial installation. Documented the condition with photographs showing the gas line assembly and HVAC mechanical room configuration. Determined that a licensed electrician is required to properly run grounding wire from the gas-tight connection back to the ground rod to restore proper electrical bonding and meet code requirements.
Responded to low water pressure complaint affecting the upper level of a 10-year-old residence. Upon arrival, confirmed that water pressure issues occurred only when the water softener was in service, with normal pressure restored when the system was bypassed. Performed diagnostic testing on the water softener system and identified that the softener control head was malfunctioning and not fully shifting during regeneration cycles, restricting water flow and causing reduced pressure throughout the upper level plumbing fixtures. The control head's failure to complete proper valve positioning prevented water from passing through the system at full volume. Provided estimate for replacement of the defective softener control head and complete resin bed replacement to restore proper system operation and water pressure. Documented equipment condition with photographs showing the existing water softener tank, brine tank, control head assembly, and associated plumbing connections. Submitted serv
Completed scheduled maintenance tune-up on a six-year-old Bryant high-efficiency gas furnace as part of routine preventative service agreement. Conducted comprehensive safety and performance inspection with no issues reported from previous heating season. Verified burner operation with proper blue flame combustion pattern across all burners. Inspected and confirmed air filter cleanliness, flame sensor condition, hot surface igniter integrity, and all electrical connections secure and functioning properly. Tested and verified gas pressures within manufacturer specifications. Switched humidifier system from summer to winter mode and activated for heating season operation. Inspected blower motor assembly, condensate drain system, and gas valve assembly. All system components found to be in good working order with no immediate concerns or deficiencies identified. Unit operating safely and efficiently, ready for heating season.
Responded to callback for two non-operational gas fireplaces following recent boiler and garage heater installation. Upon inspection, determined that pilot lights on both Napoleon gas fireplace units had not been relit after the initial installation work. Successfully relit pilots on both units, verified ignition sequence, and tested full operation to confirm proper flame characteristics and thermostat response. Both fireplaces now functioning as designed.
Responded to service call for leaking toilet with failed wax ring seal and inoperative shut-off valve. Upon inspection, identified leaking bolts and gaskets at the base of the toilet fixture. Assessed condition of mounting hardware and sealing components, noting corrosion and deterioration around the flange area. Documented existing conditions and provided estimate for complete toilet replacement due to extent of seal failure and compromised mounting system.
Responded to emergency service call for leaking 21-year-old natural gas 40-gallon water heater. Upon inspection, confirmed active leak from tank indicating internal failure beyond economical repair. Disconnected and drained existing unit, then removed failed water heater from utility area. Installed new Bradford White 40-gallon natural gas water heater to manufacturer specifications. Connected copper supply and distribution lines with proper brass fittings and shut-off valves. Installed code-compliant temperature and pressure relief valve with discharge pipe. Verified all gas connections for proper operation and leak-free performance. Tested unit functionality and confirmed proper ignition, burner operation, and hot water delivery throughout home plumbing system. Removed old water heater from premises and left work area clean.
Responded to no cooling call on system over 10 years old displaying Code 72 thermal cut-off lockout. Upon inspection, found outdoor condenser coil completely blocked with debris and contamination. Thoroughly cleaned and rinsed condenser coil to restore proper airflow. After cleaning, attempted system startup and discovered compressor exhibiting excessive vibration and internal metal rattling noises indicating mechanical failure. Verified refrigerant charge was within acceptable range, confirming compressor internal component failure as root cause of thermal lockout and loss of cooling capacity. Performed courtesy inspection of indoor furnace unit and identified questionable areas on heat exchanger showing signs of potential deterioration. Advised homeowner of heat exchanger condition and recommended monitoring throughout remaining heating season with annual inspection. Documented findings with photographic evidence showing condenser unit exterior condition and contaminated coil surfa
Responded to emergency service call for tankless water heater triggering carbon monoxide detector in basement. Upon inspection, identified unglued PVC exhaust joint allowing combustion gases to escape into living space during unit operation. Properly cleaned, primed, and solvent-welded the disconnected exhaust joint to restore safe venting. Tested unit operation and confirmed carbon monoxide detector no longer alarming. Customer reported inadequate hot water duration during extended use, indicating potential capacity or performance issues with existing tankless system requiring further evaluation for replacement options.
Completed scheduled heating maintenance on a 4-year-old Lennox furnace system. Performed comprehensive tune-up including operational testing, air filter replacement, gas pressure verification, and temperature rise measurements which confirmed readings within manufacturer specifications. Cleaned flame sensor and inspected igniter for proper operation. Verified pressure switch ports for clear operation. All system components tested and found operating correctly with no deficiencies noted.
Performed furnace tune-up on 8-year-old 80% efficiency unit located in mechanical closet. Completed standard maintenance including component inspection, gas pressure verification, and air filter check—all operating within normal parameters. Discovered critical safety hazard: inadequate combustion air in mechanical room serving both furnace and natural draft water heater sharing common exhaust. Evidence of backdrafting observed with melted plastic near water heater vent due to insufficient combustion air supply. Unit tagged out per safety protocol due to hazardous operating conditions. Additionally identified failing inducer motor exhibiting excessive noise reported by homeowner from previous season. Documented conditions with photos of motor assembly and system components. Recommended immediate combustion air remediation for mechanical room and inducer motor replacement. Submitted request for pricing on combustion air solution. System remains tagged until safety concerns are addressed
Performed annual furnace maintenance on 7-year-old system including complete operational testing, air filter replacement, and temperature rise verification. Cleaned flame sensor, tested igniter functionality, and cleared condensate drain line. Inspected air exchanger (found in satisfactory condition) and heat exchanger with no issues detected. Conducted capacitor testing on both inducer and blower motors using multimeter—blower motor capacitor tested weak and requires monitoring. Discovered oil leaking from underside of blower motor, indicating potential bearing failure. Demonstrated findings to homeowner on-site and documented condition with photos. System currently operating within normal parameters despite motor oil leak. Recommended warranty verification and provided information for potential blower motor replacement to prevent future failure.
Completed comprehensive HVAC maintenance agreement including full furnace and air conditioning system tune-up. Performed furnace diagnostics verifying proper gas pressure, tested and cleaned flame sensor, confirmed igniter operation, tested blower capacitor, and verified condensate drain functionality with clean air filter. Conducted air conditioning service including condenser coil cleaning, component inspection, and refrigerant pressure verification with all systems operating within manufacturer specifications.
Responded to water leak at commercial mop sink located in rear of building. Upon arrival, identified failed valve at connection point and severely clogged drain filled with straws and debris. Replaced malfunctioning valve with new unit and thoroughly cleaned drain line to restore proper drainage. Tested system for leaks and verified proper operation before completing service.
Responded to water softener malfunction displaying PL22 and J 2.0 error codes with continuous beeping and excessively salty water output. Diagnosed broken discharge fitting causing water spray and identified improper backwash cycle duration preventing adequate regeneration. Documented equipment condition with photographs and provided repair recommendations, with property owner electing to attempt self-replacement of the unit.