with Purchase of Furnace & Air Conditioner
Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
We are also the go-to service provider for HVAC repair and installation in Hudson, Wisconsin. Our technicians are trained to work on all types of heating and cooling systems.
If your HVAC system isn’t working as it should, our specialists can provide prompt and effective furnace repair services and heating repair for homeowners in the Hudson, WI area.If your system is not able to be fixed, our professionals also offer reputable furnace installation services and will help you choose a system with the correct capacity for your house. Regardless of the issue, our skilled technicians will help restore the distribution of warm air in your living space.
It is highly recommended that you keep your HVAC and plumbing systems well-maintained and inspected often. Ensuring that your HVAC and plumbing systems receive the servicing they need will help prevent costly repairs, help your systems last longer, and help them withstand the severe winters.
We provide our customers with maintenance plan options as well as a 12-month 100% parts and labor warranty on repairs and replacements. As a member of our Hurlburt Family Rewards Club, you can save on repairs and energy costs in addition to receiving priority service.
At Hurlburt, we know how important it is to keep your system protected all year round. We are proud to offer residential, commercial, and emergency HVAC and plumbing services to cover all of your plumbing, heating, and cooling needs.
To find out more about getting our Hudson heating air and plumbing services, contact us today. If you would like to read about other customer’s experiences with us, we invite you to check out our reviews below!
There are many ways to find plumbers, including looking through magazine or newspaper ads, getting referrals from friends, and searching the internet for local plumbers in your area. But how do you know what kind of service you’re going to get before you hire them?Here are a few tips on how to find a good-quality plumber:
Make sure they’re certified. Read their reviews. Check to make sure they have many years of experience. AtHurlburt, we’ve been delivering high-quality services since 1959. Our friendly technicians strive to give you the best customer service possible so that no matter what you need, you feel satisfied with our work. If you’d like to learn more about the many services we offer, give us a call today!
Typically, most people will spend anywhere from $5,000-$10,000 on HVAC system replacement, with the average cost for replacement being about $7,000. This covers both the cost of the system and the cost of labor. However, some of the more high-end systems can get up to $20,000, so the replacement costs will vary depending on what kind of systems you purchase.Hurlburt offers unparalleled HVAC services. No matter what you need, we’ll work hard to ensure that we get the job done to your satisfaction. To find out more about our HVAC system replacement services, call us today!
The cost for HVAC repairs depends heavily on what system needs fixing and what the problem with it is. The average cost to have your AC systems repaired is about $320, with the average range being anywhere from $125-$450. For furnace repair, the average cost can fall anywhere from $130-$450, with most people paying around $250-$300. However, these numbers can be considerably lower or higher depending on the extent of damage to the unit and any parts that need replacing.At Hurlburt, we offer expert services and we are available to take your call 24/7. No matter when your HVAC systems have problems, we can help get them back up and running in no time. Call us for more information on how we can help you today!
Hurlburt in Hudson, WI provides a full range of electrical services aimed at keeping your home’s electrical systems functioning optimally and safely. Their offerings include precise electrical repairs for immediate concerns and the installation of whole-home generators to keep your power running smoothly during blackouts. The company’s technicians are committed to delivering excellent service and dependability. They also specialize in electrical panel services, essential for keeping your home’s electrical core in top condition, preventing hazards, and boosting electrical efficiency. Whether it involves updating your existing panel to support new appliances or just making sure your system is up to safety codes, Hurlburt‘s professionals offer reassurance with each service interaction.
Our professional team offers comprehensive electrical installation services that can significantly improve the comfort and functionality of your home. Their services include the installation of new lighting, which can completely alter the feel of your rooms, and the addition of more electrical outlets to support an increasing number of gadgets. Hurlburt also offers ceiling fan installations to maintain comfortable temperatures and enhance energy efficiency. They are committed to performing every job with a focus on safety and precision, ensuring reliable and seamless electrical solutions.
In Wisconsin, Hurlburt provides expert duct cleaning services that aim to improve both the performance of your air conditioning and the air quality within your home. Accumulated dust, allergens, and debris in ductwork can hinder airflow and decrease your HVAC system’s efficiency over time. Utilizing Hurlburt’s services can ensure that your air conditioning system functions at its best, which can reduce energy costs and extend the system’s lifespan. Moreover, the removal of these contaminants leads to better air quality, reducing respiratory irritants and promoting a healthier living space.
Responded to no cooling call on 10+ year old Energy Knight mini split system. Upon arrival, found indoor unit operating but outdoor condenser unit not running. Inspection revealed mouse nest inside outdoor unit with numerous loose electrical connections. Removed rodent nesting material, cleaned affected areas, and tightened all loose wire connections at terminal block. Tested system operation and confirmed outdoor unit now running properly with normal cycling.
Completed scheduled maintenance agreement service on Daikin mini-split system. Performed comprehensive tune-up including cleaning outdoor condensing unit, rinsing condenser coils, flushing condensate drains, and cleaning filters. Tested all indoor head units for proper operation and verified system performance meets manufacturer specifications.
Responded to service call for generator system that failed to activate during power outage. Upon inspection, discovered the second transfer switch was not properly wired to receive signal from generator when operational. Diagnosed that transfer switch lacks necessary communication wiring to trigger automatic switching sequence. Documented electrical connections and terminal blocks within system. All required components are present on-site. Recommended licensed electrician return to complete proper wiring integration between generator control system and secondary transfer switch to restore full automatic transfer functionality across all circuits.
Responded to an active emergency water leak in the basement where water was pouring from a deteriorated galvanized kitchen drain pipe onto the walls and floor. Upon arrival, shut off the water supply to stop ongoing water damage. Identified the source as a rotted-out section of galvanized drain pipe. Cut out the compromised galvanized piping and replaced it with new materials to restore proper drainage function and eliminate the leak.
Installed electrical disconnect box on exterior wall adjacent to air conditioning condenser unit that was previously operating without proper safety disconnect. Ran new electrical whip from disconnect to condenser and replaced low voltage communication wire from indoor furnace to outdoor unit. System tested and verified to be operating normally with all electrical connections properly secured and compliant with safety requirements.
Responded to warranty call for recently installed system blowing warm air instead of cooling properly. Discovered furnace was cycling on due to basement thermostat setpoints being too close together while in auto mode. Deactivated basement thermostat, placed unit in test mode, and verified refrigerant charge was within specifications. Unit tested at 49°F discharge air temperature, confirming proper cooling operation. Adjusted thermostat programming to prevent future conflicts between zones.
Installed customer-supplied widespread three-piece lavatory faucet with matte black finish in upstairs bathroom. Removed existing antique faucet assembly and connected new fixture to supply lines, ensuring proper sealing and alignment with undermount sink. Tested operation of both handles and spout for proper water flow and verified no leaks at all connection points.
Responded to a leaking toilet issue on an American Standard unit. Diagnosed a failed flush valve gasket causing water to leak through the flush valve assembly. Replaced the defective flush valve gasket, restoring proper seal and eliminating the leak.
Responded to a broken dishwasher angle stop valve where the handle had completely broken off, preventing proper water shut-off capability. Replaced the defective angle stop valve with a new unit, restoring full water control functionality to the dishwasher supply line. All connections were tested for proper operation and verified leak-free upon completion.
# HVAC Service Report Responded to no cooling complaint on 18-year-old residential air conditioning system. Upon arrival, confirmed outdoor unit condenser fan motor was not operating. Performed diagnostic testing and identified failed dual run capacitor as root cause of system failure. Capacitor tested outside acceptable microfarad range, preventing fan motor from starting while compressor attempted to run. Replaced defective capacitor with properly rated OEM equivalent part. Verified correct wiring connections and secure mounting. Started system and confirmed condenser fan motor operation restored. Monitored system through complete cooling cycle. Verified proper refrigerant pressures and temperatures using digital manifold gauges. All operating parameters returned to normal specifications. System cooling effectively upon departure.
Responded to no cooling call on 10+ year old residential air conditioning system. Upon arrival, found outdoor condenser unit humming with heat discharging from top but fan motor not operating. Performed diagnostic testing and identified failed capacitor preventing fan motor operation. Replaced defective capacitor with proper OEM replacement. Verified system operation with digital manifold gauges, confirming proper pressures and temperatures. Unit restored to normal cooling operation with condenser fan running properly.
Responded to no cooling complaint on commercial AC unit installed 11 months prior. Found system completely flat on refrigerant with no pressure detected. Recharged system to manufacturer specifications and injected UV leak detection dye into refrigerant circuit. System restored to operational status temporarily, but follow-up visit required to locate and repair refrigerant leak using UV detection equipment once dye has circulated through system.
Responded to a water leak in the basement originating from the kitchen drain line above. Performed investigative access by cutting into the ceiling to locate the source. Identified a cracked ABS 90-degree elbow fitting on the kitchen sink drain line. Removed the damaged fitting and replaced it with a new 90-degree elbow using a Fernco flexible coupling to ensure a watertight seal. The leak has been successfully repaired and the drainage system restored to proper operation.
Responded to no cooling complaint on system installed one year prior. Upon inspection, discovered system was completely out of refrigerant, indicating a leak in the system. Recharged system with refrigerant and added UV dye to identify leak location. Follow-up appointment scheduled to inspect for dye traces and pinpoint exact leak location for repair.
Responded to no cool call on 6-year-old Goodman air conditioning system. Upon arrival, confirmed outdoor unit was not receiving power and system was non-operational. Diagnosed failed control board on indoor furnace unit, which was preventing proper communication between thermostat and outdoor condenser. Control board showed no voltage output to contactor circuit despite proper incoming power and thermostat signal. Replaced defective integrated furnace control board and restored all low-voltage wiring connections to proper terminals. Verified thermostat communication, tested system startup sequence, and confirmed outdoor unit now engaging properly with adequate amperage draw. System cooling normally with proper temperature split across evaporator coil. Also assessed water heater for potential maintenance scheduling per customer request.
Responded to no cooling complaint on 23-year-old R-22 system with 6-degree temperature differential between setpoint and actual room temperature. Upon arrival, found evaporator coil completely frozen, preventing proper heat exchange and airflow. Homeowner reported previous refrigerant recharge performed several years ago, indicating potential ongoing leak in system. Due to frozen condition of coil, unable to perform complete diagnostic testing including static pressure measurements at time of service. Documented existing system configuration including ECM blower motor in current furnace. Observed ongoing comfort issues with inadequate cooling to second floor, consistent with possible airflow restrictions, undersized ductwork, or insufficient system capacity for multi-level application. Previous technician had attempted to address zoning issues through manual damper adjustments at supply registers. Provided detailed explanation of R-22 refrigerant phase-out, leak repair options, and a
Responded to no cooling complaint on residential air conditioning system over 10 years old. Upon arrival, diagnosed blown fuse preventing unit operation. Replaced failed 25-amp time-delay fuse with Bussmann heavy-duty replacement. Verified proper system operation, confirmed adequate refrigerant levels, and restored cooling function to the home.
Successfully installed customer-supplied kitchen faucet in residential kitchen. The new pull-down faucet with curved spout in brushed nickel finish was mounted above the sink area, with all connections properly secured and tested for leaks. Installation was completed after reviewing pricing details with the homeowner prior to commencing work.
Responded to no cooling complaint on residential air conditioning system. Found failed capacitor that had been previously installed by our company. Capacitor had catastrophically failed and required replacement. Replaced defective capacitor under warranty at no charge to customer. System tested and verified proper operation with adequate cooling restored.
Conducted on-site assessment for water heater replacement options. Customer requested quote for heat pump water heater installation with preference for 40-gallon gas unit. Documented existing Richmond Integra 6-year warranty gas water heater installation, photographed current mechanical room configuration including furnace, water softener system, plumbing connections, and copper piping with shutoff valves for accurate replacement planning and specifications.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions | [cookie_preferences_link]
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.