When you get your heating, air conditioning, and plumbing service through us, you can be assured that it is done properly. Check out our reviews below to read what your neighbors are saying about our heat, AC, and plumber services in Wilson, WI.
Replaced malfunctioning zoning control and upstairs thermostat per estimate to resolve system issues that were not corrected by previous thermostat replacement. After installation, verified all zones linked up properly, adjusted fan speeds for heating and cooling modes, and reviewed thermostat functions with homeowner to ensure proper system operation.
Responded to service call for Lennox Pulse furnace experiencing short cycling issues, with burner igniting for approximately 45 seconds before shutting down repeatedly. Upon arrival, confirmed unit was cycling on and off continuously. Disassembled furnace and performed pressure test on heat exchanger, which passed successfully. Advised homeowner that unit is aging and replacement parts are becoming unavailable from manufacturer. Reassembled unit and conducted component testing to diagnose continued operational issues. Testing revealed control board was malfunctioning and generating false flame signal readings, preventing unit from maintaining steady operation. After discussing findings and repair options with homeowner, received approval to proceed with control board replacement. Installed new control board and verified furnace achieved stable operation with normal run cycles. Unit tested successfully post-repair. Homeowner requested follow-up appointment for new furnace replacement pr
Responded to customer concern regarding missing piping under kitchen window that was removed during previous installation but not reinstalled. Verified furnace intake and exhaust installation was completed properly with no deficiencies found. Documented electrical panel and system configuration with photos for service records, confirmed no corrective action required at this time.
Replaced leaking hammer arrestors on laundry fixture that was previously serviced. Customer had water turned off to prevent leakage. Visual inspection confirmed proper installation of new arrestors with secure copper pipe connections in the recessed wall access area.
Responded to a water leak emergency in the kitchen originating from the bathroom above. Upon inspection, discovered a faulty SharkByte toilet supply line connection causing the leak. Replaced the defective supply line and verified proper operation with no further leakage.
Diagnosed and repaired multiple water leaks at residence. Found corroded washing machine shutoff valve and leaking packing nut on ice maker angle stop. Replaced washing machine shutoff with new 2t-m2 valve and tightened packing nut on ice maker angle stop to resolve leaks. Restored water service to home.
Responded to warranty service call for recently installed water treatment system. Installed a hose adapter to existing ball valve on filtration unit, allowing customer to properly flush the softener tank without water spillage.
Completed replacement of 2-inch shower drain strainer and trap assembly that was leaking. Removed old components, installed new shower strainer and trap per estimate. All connections were properly sealed and system was tested for proper drainage with no leaks observed.
Diagnosed zone control system failure causing inadequate heating in upstairs zone (Zone 2). Testing revealed thermostat communication issues with zoning system, leading to heating deficiency and excessive window condensation. Determined zone control board is malfunctioning with intermittent power cycling; recommended replacement of zone control board and upstairs zone thermostat.
Responded to emergency service call for water leak on filtration system. Upon inspection, identified loose filter housing as source of the leak. Tightened filter housing to manufacturer specifications, which successfully resolved the leak. System tested and confirmed proper operation with no further water loss.
Diagnosed homeowner's no-heat complaint and found a non-functioning smart thermostat despite proper power supply to the unit. Determined the thermostat control board was failing and installed a new S40 thermostat. System is now operating properly with both zones functioning as designed on the 2016 Lennox natural gas furnace.
Responded to call for RS12-4 condensing boiler (LP, 4 years old) displaying overheating code and shutting down after only 10 seconds of operation. Inspection revealed blocked combustion air intake with debris and a bumblebee obstructing proper airflow. Preliminary diagnosis indicates possible scaling on heat exchanger per manufacturer's technical information. Unit was powered off for safety as heat exchanger temperature was excessively high. Return visit scheduled to perform full diagnosis with manufacturer technical support and determine if descaling procedure is required to restore proper operation.
Diagnosed and repaired no heat condition on recently installed furnace. Found two issues: improperly pitched exhaust piping was corrected by cutting and re-gluing with proper slope back to unit, and cleared blockage in condensate drain system that had caused inducer motor to fill with water. Restored proper drainage and verified normal heating operation after repairs.
Responded to a no-heat call for an 80's era furnace blowing cold air. Upon arrival, system was locked out due to overheating with supply air temperatures approaching 150°. Diagnosed severely restricted airflow with almost 1" WC static pressure on return side and minimal static on supply side. Found only two functional returns throughout home, multiple closed vents, and heavy dust accumulation in ductwork. Reset system, opened basement vents, verified all supplies were open, and inspected burners (found crusty). Noted system using cooling wire on blower for heating due to furnace running hot. Verified proper gas pressure, correct orifice, and functioning blower capacitor.
Performed standard oil furnace tune-up including nozzle replacement and filter change. Inspected capacitor and found it in working condition. Identified and addressed oil leak at filter housing by replacing filter and gaskets, with no residual leakage observed after repair. Advised customer that oil tank gauge readings appear inaccurate, though customer is aware of current oil levels.
Completed annual furnace tune-up on 9-year-old system as part of 2x yearly recurring service agreement. Performed comprehensive inspection of heating components including examination of evaporator coil condition and electrical connections. All systems functioning properly with no issues identified.
Diagnosed heating system failure in white boiler with no flow to house. Identified multiple issues including a stuck floor control valve, faulty pressure gauge, and possibly malfunctioning ball valve near circulator pump. Replaced pressure/temperature gauge, freed up control valve to restore water flow, and installed relief valve. System was properly pressurized and bled out; however, circulation issues persisted despite pump appearing operational. Recommended expansion tank replacement and auto fill system upgrade from filter trial to conventional configuration. Scheduled follow-up service with boiler specialist for further diagnosis.
Responded to a return service call to install a relief valve on customer's boiler system. Successfully installed the relief valve and performed a complete system bleed, but noted the boiler was still overheating due to poor water circulation. Inspection revealed the circulator pump was operational but ineffective, with a potentially defective ball valve above the pump that may have a broken shaft preventing proper opening/closing. Recommended further diagnosis by a boiler specialist.
Responded to service call for a leaking piercing valve on a 3/8" hot water line that was failing to shut off after HVAC contractor removed an old humidifier. Removed the defective piercing valve and repaired the damaged section of copper piping using a SharkBite coupling to restore proper system operation.
Diagnosed 20-year-old boiler system not producing heat due to overheating from insufficient water circulation and a leaking relief valve. Opted against adding water to the hot cast iron boiler to prevent damage. Ordered new relief valve and recommended system bleeding to restore proper circulation, with contingency plan for possible circulator pump replacement if needed.