When you get your heating, air conditioning, and plumbing service through us, you can be assured that it is done properly. Check out our reviews below to read what your neighbors are saying about our heat, AC, and plumber services in Stockholm, WI.
Hurlburt Heating & Plumbing has completed 20 jobs in Stockholm, WI between October 2025 and December 2025.
The most recent job was on December 29, 2025.
Hurlburt Heating & Plumbing has completed 58 jobs in Stockholm, WI in the last 12 months. The first job there was in October 2015.
Responded to a no-heat service call for an older boiler system. Upon inspection, discovered a condensate cup that wasn't properly tightened, causing ongoing leakage since installation. Tightened the component to stop the active leak, cleaned the affected floor area, and noted some black organic growth on the back wall which customer acknowledged. Advised customer to periodically check the area for any future leakage issues.
Responded to emergency water leak caused by broken shower handle. Inspected the Moen shower valve assembly and identified a failed cartridge as the source of the leak. Successfully replaced the defective Moen cartridge, restored proper functionality to the shower control, and verified complete resolution of the leak. Water service to home was restored after repair verification.
Responded to no-heat call on 3-year old HVAC system. Customer reported circulation motor issues with diagnostic flash codes 1+2. Upon inspection, determined that customer was not allowing for the system's required 90-second purge cycle before fan operation. Demonstrated proper operation to customer, verified multiple successful heating cycles, and confirmed system is functioning as designed with no repairs needed.
Performed routine maintenance on a 4-5 year old LP furnace in mobile home. Conducted comprehensive inspection including heat exchanger evaluation, operational testing of all components, and standard tune-up procedures. All systems functioning properly with no defects or issues identified.
Responded to emergency service call for a broken pipe in garage causing water leakage. Diagnosed cracked ball valve that had failed due to freezing conditions. Successfully replaced damaged ball valve and adjacent pipe section, restoring proper water flow and preventing further leakage into the garage area. System tested and confirmed operational.
Successfully completed a repair by replacing the combustion inducer assembly and all four main burners per approved estimate. System was test run for 30 minutes following installation to verify proper operation and performance.
Performed fall maintenance and winter startup on geothermal system, verifying proper operation. Identified and corrected valve settings on Munchkin boiler, adding written instructions directly on the unit for client reference. Added water to the load side as needed and sold replacement register to be installed on a future visit.
Responded to no heat complaint for 17-year-old LP system serving mixed-use building. Diagnosed tripped limit switch on inducer caused by recently installed filter after previous filter was heavily clogged. Reset limit switch, performed heat exchanger inspection, and restored heat operation. Noted significant rust on burners and concerning inducer motor noise; provided customer with replacement options for these degraded components.
Responded to service call at customer's bunk house for a missing plug on the side of the Goodman furnace, which was likely dislodged during previous gas valve replacement service. Located and reinstalled the missing furnace plug to restore proper operation and system integrity.
Diagnosed 32-year-old oil boiler that was not firing. Investigation revealed a wire had become disconnected from the electrode, likely from previous service interaction when nozzle work was performed. Reconnected the wire securely to the electrode and verified proper system operation. System now functioning normally.
Successfully installed new Amtrol expansion tank as per approved estimate. System was refilled, air purged from lines, and proper operation verified after installation. All work completed according to specifications with residential hydronic heating system now functioning correctly.
Replaced cracked PVC bushing on Rusco R500 sediment filter system which was actively leaking. Installed new filter assembly and re-piped connections to ensure proper operation and eliminate water leakage.
Responded to service call for non-starting boiler system in gym. Discovered low system pressure and refilled system, but unit continued to overheat. After assessment, determined potential circulation pump failure preventing proper water movement through the system. Temporarily resolved overheating by adjusting valve positions to force full system circulation, which successfully restored heating to the building. Recommended follow-up visit by senior boiler technician to conduct comprehensive diagnosis and address potential pump issues.
Performed diagnostic service on older gas furnace experiencing ignition failure issues. Upon inspection, furnace was operational but homeowner reported previous intermittent operation with lockout conditions. Conducted thorough maintenance including flame sensor cleaning and burner removal, discovering significant rust buildup between burners which was inhibiting proper combustion. Cleaned components and restored normal operation, with recommendation to replace burners during next scheduled maintenance to prevent recurrence of ignition failure.
Performed diagnostic evaluation on non-functioning cottage furnace. Identified faulty gas valve as primary issue. Replaced gas valve, properly calibrated pressure settings for LP gas, and verified complete system operation. Furnace now operating correctly with heat restored to cottage.
Serviced 2-year-old Amana furnace with ignition failure. Performed maintenance including cleaning flame sensor, burners, and condensate system. Restored proper ignition and verified operation; furnace now functioning correctly.
Performed scheduled maintenance tune-up on 8-year-old Lennox high efficiency furnace. System was functioning properly at time of service with no operational issues observed. Customer declined additional service options, requesting only basic heat maintenance.
Responded to no-heat service call for boiler system displaying error code SLT-11603. Diagnosed inadequate airflow issue and identified faulty combustion blower and temperature sensors. Replaced combustion blower and determined both supply and return temperature sensors require replacement due to temperature differential readings (return 81°F reading higher than supply 75°F). Parts ordered for completion of repair.
Performed annual fall tune-up on residential HVAC system under Reward membership agreement. Conducted comprehensive service check on Lennox furnace, dehumidifier, humidifier, and multiple mini-split units located in garage and back room. All systems verified to be in proper working order with no issues identified.
Completed furnace tune-up on 20-year-old system. During inspection, identified severely corroded secondary heat exchanger tubes with active leakage. Visual inspection findings were shared with customer using camera. Equipment was tagged out and shutdown for safety, and scheduled follow-up appointment with service advisor for replacement options.