Hurlburt Heating & Plumbing has completed 20 jobs in Stockholm, WI between July 2026 and October 2026.
The most recent job was on October 7, 2026.
Hurlburt Heating & Plumbing has completed 56 jobs in Stockholm, WI in the last 12 months. The first job there was in October 2015.
Completed scheduled fall heating maintenance on geothermal system and backup gas-fired Munchkin boiler. Added water to geothermal loop and in-floor heating system, verified all geo components and operation including pressures and temperatures, replaced air handler filter with customer-supplied unit, and tested gas boiler for proper startup and operation.
Completed comprehensive tune-up service on two residential furnaces as part of reward membership maintenance program. Primary unit is approximately 20 years old, backup unit is approximately 18 years old. Both systems inspected burner assemblies showing significant age-related corrosion and oxidation on heating elements but remain operational. Performed full preventative maintenance procedures per tune-up checklist on both furnaces. Systems confirmed in acceptable working condition considering age of equipment.
Responded to no heat call on Weil-McLain boiler in barn. Upon inspection, unit was igniting properly but shutting down prematurely. Discovered birds nest obstructing exhaust vent causing improper combustion air flow and flame rollout safety shutdown. Removed nesting material and debris from exterior exhaust piping back to unit. Interior exhaust components require cleaning with proper tooling during scheduled maintenance. Restored heat operation and recommended comprehensive boiler tune-up to address remaining maintenance needs.
Removed and disposed of existing toilet fixture. Installed new Toto Drake 2-piece toilet with integrated Toto Washlet bidet seat. Ensured proper wax ring seal at floor flange connection and verified all water supply connections were secure and leak-free. Tested toilet flush operation and bidet functionality to confirm proper installation and performance.
Completed annual furnace tune-up as part of recurring maintenance agreement. Performed comprehensive inspection and service per standard tuneup protocol. Furnace found to be in generally good operating condition with all primary components functioning properly. However, inspection revealed that the counterflow evaporator coil requires replacement due to condition concerns. Documentation and estimate for evaporator coil replacement has been provided for customer review and approval.
Responded to service call for boiler making unusual "mooing" noise after system was switched from geothermal to boiler heating mode. Ran boiler for approximately 20 minutes but did not observe the reported noise; suspected moisture on burner caused temporary dirty combustion that has since resolved. During inspection, discovered low water cutoff safety control was triggering and causing system alarm. Cleaned low water cutoff and added water to boiler, but safety control continued to alarm, indicating component failure requiring replacement. Ordered replacement low water cutoff and ignition module board as precautionary measure. Tested geothermal system operation and confirmed proper function. Additional boiler cleaning in garage required upon return visit to complete work with ordered parts installation.
Completed comprehensive kitchen plumbing installation including new faucet, copper/bronze finish sink with basket strainer, supply line shut-off valves, and dishwasher hookup on marble countertop. Replaced sediment cartridge in whole-house water filtration system. Performed inspection of 9-month-old electric water heater. All fixtures tested and verified leak-free with proper operation confirmed.
Responded to service call for cracked toilet tank requiring immediate replacement. Removed existing failed toilet and installed new Gerber Viper elongated comfort height toilet. Addressed uneven floor condition by shimming toilet to ensure proper level and stable installation. Connected water supply line and performed leak testing with five consecutive flushes to verify proper operation and confirm no leaks at tank, bowl, or supply connections. Installation completed successfully with unit functioning properly.
Performed scheduled A/C and furnace tune-up inspection. Air conditioning system inspected and found operating within normal parameters with evaporator coil and refrigerant lines functioning properly. During furnace inspection, discovered 30-year-old boiler with severely compromised burner assembly—burners completely plugged with soot despite being only two years old. Extensive soot accumulation found throughout boiler combustion chamber. Investigation revealed presence of mothballs stored in proximity to boiler, which when exposed to combustion can produce caustic byproducts leading to accelerated corrosion and burner deterioration. Evidence of rodent activity observed inside boiler unit with insulation damage noted. Due to unsafe operating condition, shut down gas supply and electrical power to boiler until unit can be properly cleaned with new burners installed or full boiler replacement completed. Documented conditions with photographs. Recommended scheduling appointment with adviso
Responded to service call for water softener displaying ERR1 error code and failing to drain properly. Upon inspection, diagnosed 7-year-old unit with malfunctioning motor preventing water discharge through drain port during regeneration cycle. Motor mechanism not operating correctly, causing system to fill with water and halt regeneration process. Evaluated cycle controller assembly and drainage components to confirm motor failure as root cause. Documented equipment condition with photographs showing cycle controller, valve assembly, PVC plumbing connections, and complete water treatment system configuration including associated filtration components. Provided customer with multiple repair options including motor replacement, complete resin rebed service, or new water softener unit installation to restore proper system operation.
Responded to a slow-draining shower drain where the homeowner had unsuccessfully attempted to clear the blockage using a hair zipper tool. Upon inspection, identified a significant clog located approximately 5 feet down the drain line consisting of accumulated pet hair. Successfully cleared the obstruction using a drain auger, restoring proper drainage to the shower.
Responded to service call regarding shower head compatibility issue with recently installed valve. Upon inspection, determined that the shower valve installed by our company was incompatible with the customer-supplied shower head and trim kit. The property owner had requested installation of their purchased valve, but our valve was installed instead. Documented the specifications and finish of the desired trim kit (dark bronze) through photographs to source matching replacement components. Advised that correct trim kit in matching color and similar style will be provided and installed under warranty to ensure compatibility with customer's preferred fixtures. Additionally, installed shut-off stops for the bathroom vanity rough-in while on site.
Responded to callback for boiler water leak on floor. Removed insulation to access heat exchanger and water tank, traced leak source to condensate line. Disassembled and thoroughly flushed condensate line, cleared blockage in drain pipe. Reassembled system and tested operation—unit ran properly with no visible leaking. However, suspect potential pinhole leak in heat exchanger that may be allowing boiler water to drain internally. Resolved immediate floor water issue through condensate system cleaning. Recommend monitoring hydronic side for low water conditions during fall maintenance visit, as homeowner shuts off water supply when away from property, making continuous observation difficult during summer months.
Responded to a clogged bathroom sink drain caused by excessive hair accumulation in the tailpiece and trap assembly. Disassembled the P-trap, removed all hair buildup from both the trap and tailpiece, and reassembled the drain system. Verified proper water flow and drainage upon completion, with sink now functioning normally.
Performed air conditioning tune-up on rental property unit. Found condensing coil completely plugged with debris, causing inadequate cooling performance. Thoroughly cleaned and washed out coil, restoring proper airflow. Verified system operation with refrigerant diagnostics showing 18° superheat and 8° subcooling, with satisfactory temperature drop across evaporator coil. Noted poor installation quality of air handler and furnace by previous contractor. Customer disconnected thermostat to reconnect to smart device after service completion.
Responded to no-cooling complaint on recently installed system that was unable to reduce indoor temperature below 77°F despite running continuously for 7 hours. Upon arrival, performed operational testing which confirmed system was functioning properly with temperature split exceeding 15 degrees across the evaporator coil. Investigation revealed all basement ceiling registers were fully open, causing significant conditioned air loss to the lower level and inadequate airflow to the main floor. Closed all basement registers to redirect airflow to upper living areas and conducted multiple operational tests to verify proper system performance. Temperature split remained consistent above 15 degrees, confirming adequate refrigerant charge and proper heat exchange. Explained to homeowner that extended run times are expected during periods of extreme outdoor temperatures and that the system may be slightly undersized for the total square footage of the home. Recommended monitoring system perfo
Responded to no cooling complaint on 8-year-old air conditioning system with indoor temperature exceeding 80 degrees. Performed system diagnostics and found low refrigerant charge indicated by low suction pressure, low subcooling, and high superheat readings. Added 2 pounds of refrigerant to system and conducted leak detection; no significant leaks identified at time of service.
Performed comprehensive maintenance on four mini-split units at a church facility. Two units on the cemetery side received deep cleaning service, which included full disassembly of the indoor heads, exterior washing of components, reassembly, and operational verification. The remaining two mini-split units on the opposite side of the building received standard tune-up service. All four systems were inspected and confirmed to be operating properly upon completion.
Completed follow-up service call to address previous water discharge from relief valve. Replaced auto fill valve and backflow preventer to correct system over-pressurization issue. Refilled hydronic system, purged air by leaving automatic vent open on expansion tank, and tested all heating zones for proper operation. Installed auto filter for boiler and new pressure relief valve. All zones operated as designed with no active leaks observed at time of service.
Completed Family Rewards cooling maintenance visit on residential HVAC system consisting of two mini-split units and one heat pump. Performed operational checks on all equipment, noting minor fan buildup on living room head unit that customer declined service for at this time. Replaced customer-supplied air filter, rinsed all outdoor condenser units, and verified proper system operation across all zones. All equipment functioning within normal parameters upon completion of tune-up service.