Winter in Spring Valley brings long stretches of icy mornings and deep cold. Our team keeps your home warm with detailed heating services tailored to local weather. We work with furnaces, boilers, and heat pumps, ensuring dependable performance through each freeze. Whether you need a quick repair, a complete system replacement, or seasonal maintenance, we have you covered.
Many homeowners reach out for heating repair in Spring Valley when they notice uneven heat, rising energy use, or systems struggling to keep up. We diagnose issues quickly and offer solutions that fit your home’s layout and usage patterns. Our goal is to maintain dependable heat without disrupting your household. With Hurlburt, you always get honest guidance and steady results with emergency HVAC in Spring Valley.
When summer humidity arrives in Spring Valley, a dependable cooling system becomes essential. We support homeowners with AC installation, maintenance, and repair in Spring Valley, WI. Whether your system struggles to cool rooms evenly or shuts off unexpectedly, we provide solutions that help you stay comfortable through the warmest months.
Our AC repair in Spring Valley, WI addresses airflow problems, worn components, and system imbalances. These issues not only affect your comfort but also the indoor air quality in Spring Valley, WI. We take the time to understand how your home responds to heat and humidity and provide cooling options that improve comfort and efficiency.
Your plumbing system plays a major role in your home’s safety and convenience. We keep your water flowing with repair and installation services delivered by our trained plumbers in Spring Valley, WI. If you deal with leaks, low pressure, or fixture issues, we diagnose the cause and restore function efficiently.
Whether you plan a fixture upgrade or need quick help with a stubborn problem, you can rely on our professional plumbers in Spring Valley, WI. We treat your home with care and ensure every part of your system operates smoothly.
Safe electrical systems protect your home and family. Our electricians handle repairs, replacements, and upgrades that keep your home operating smoothly. If you notice flickering lights, outdated wiring, or unreliable outlets, you need an electrician in Spring Valley, WI.
We support remodels that involve electrical upgrades. Our electricians in Spring Valley, WI, work with precision and follow current safety standards, ensuring every project meets expectations.
Spring Valley is a tight-knit community where neighbors look out for one another. Whether you live near the Crystal Cave entrance or closer to the Eau Galle Recreation Area, you rely on dependable home systems. Our team understands the area’s unique traits, including heavy snowfalls, damp river air, and warm summer nights. We tailor our services to meet these local demands, supporting homeowners with reliable HVAC, plumbing, and electrical services.
We work throughout the village, helping homes of all sizes stay safe and efficient. When storms roll through Pierce County or temperatures fluctuate rapidly, we provide steady support.
For more than 65 years, Hurlburt has proudly served customers throughout Minnesota. We deliver reliable service backed by strong values and a commitment to excellent workmanship. With over 6,000 5-star reviews, we prove our commitment to the Spring Valley community.
When you work with us, you become a part of the family. Welcome to the Hurlburt Family! We are always here to take your call and ready to help your home stay comfortable and safe.
Contact Hurlburt today to schedule services for your HVAC in Spring Valley. We’re here when you need HVAC, plumbing, or electrical services for your home.
Replaced faulty compressor, TXV valve (12J18 1.5-3 ton screw-on R410A), and line dryer on HVAC system. System was properly evacuated, recharged with 5 lbs 11 oz of R410A refrigerant, and verified for proper operation after installation.
Completed 3-hour repair service involving replacement of a 1/2-1" three-way zone valve for basement heating system. Installed new zone valve and two new thermostats, with specific instruction to customer regarding gradual temperature adjustment (1° at a time) for basement thermostat to prevent overheating. Successfully tested floor heating system and upstairs zones, confirming proper operation of all components.
Responded to no-heat emergency call where customer reported loud buzzing noise from furnace. Diagnostic testing revealed failed blower motor with worn bearings preventing proper operation. Heat exchanger was inspected and confirmed to be in satisfactory condition. Replaced defective blower motor and capacitor, then performed system testing to verify proper operation and restoration of heat.
Performed comprehensive plumbing inspection with focus on faucet systems. Identified and cleared debris blockage at fitting where washer and shower drain lines connect, which was causing shower drain backup during washer operation. Augered drain through laundry room standpipe to ensure proper flow. Inspected stainless steel kitchen sink installation and shower stall faucet assembly for proper function.
Replaced outdated shower valve with customer-provided new unit. Removed existing valve and associated piping, then installed and secured new valve through wall cavity. Conducted pressure testing to verify proper operation with no leaks.
Completed burner assembly replacement on Ruud furnace. Disassembled unit, installed new burners, reassembled and verified proper operation with good flame pattern and restored heating function. System now operating normally.
Responded to service call for non-functional humidifier. Discovered front cover was not properly secured, preventing electrical connection. Reattached cover completely, restoring normal operation of the humidifier. Verified Aprilaire humidity control system was functioning correctly after repair. Addressed additional homeowner questions regarding HVAC system operation.
Responded to no heat complaint on 10-year-old Lennox furnace exhibiting fault codes 270 and 299. Diagnostic testing revealed intermittently sticking gas valve preventing proper gas flow. Successfully replaced faulty gas valve, restoring normal heating operation and system functionality.
Responded to no-heat call where furnace would not start. Diagnosed stuck open limit switch due to homeowner forgetting to change filter after recent sheetrock work. Inspected heat exchanger (no defects found) while limit switch was removed. Noted significant rust on burners and in blower section/furnace deck, likely from previous AC condensate drainage issues. Provided estimate for replacement burners and discussed potential furnace replacement options with homeowner.
Responded to no heat complaint in home with 10+ year old furnace. Diagnosed system with cycling issues and plugged filter caused by ultrasonic humidifier. Inspection revealed severe corrosion and deterioration of heat exchanger and burners. Customer approved estimate for burner replacement and parts order was submitted.
Inspected aging boiler system with leaking in-floor heating pump manifold at connection points. Identified blue sealant failure on KISSCO manifold with PEX distribution pipes. System is approximately 10+ years old with multiple obsolete components. After consultation with customer and colleague Dylan, recommended full boiler replacement and repiping due to system age and condition. Scheduled service advisor visit for replacement options and pricing.
Responded to warranty service call for condensate leak. Identified wet furnace filter and rust residue caused by improperly pitched chimney creating backflow. Performed necessary rework on chimney components to correct drainage issue and ensure proper condensate flow.
Responded to no heat call for 12-4 NG Gibson furnace. Diagnosed open limit/rollout switch fault with furnace sitting cold. Found main limit switch with abnormal resistance (4-5 ohms) showing signs of overheating, and capacitor measuring 2 ÎĽF despite 5 ÎĽF rating. Noted additional issues including oil-leaking blower motor, dirty blower wheel restricting airflow, evaporator coil buildup, and intermittent burner ignition. Assessment suggests oversized furnace (80,000 BTU) for the home's ductwork system.
Performed scheduled maintenance tune-up on IBC HC boiler system that provides hot water and serves as backup to geothermal system. Cleaned heat exchanger thoroughly as part of Family Rewards agreement maintenance. Inspection revealed system in good working condition with no issues or problems identified.
Diagnosed 13-year-old Comfort Maker furnace making unusual burner noise and identified failing combustion blower bearing. Inspected heat exchanger and noted suspect areas but no current penetration. Advised customer against investing in replacement parts due to age of unit and common heat exchanger failure pattern with this model. Scheduled service advisor visit for replacement options.
Performed preventative maintenance service on Lennox EL296UH070XE36B furnace. Comprehensive tune-up included verification of ignition sequence, burner operation, and proper airflow. Conducted electrical testing using clamp meter and completed full safety inspection. Unit is functioning efficiently with no operational concerns identified.
Responded to a call regarding inconsistent water pressure issues in basement plumbing system. Upon inspection, found significant sediment buildup in the 5-year-old pressure switch component of the Wells system. Removed old switch and installed new 4060 pressure switch to restore proper system function and consistent water pressure.
Diagnosed Hot Dawg heater with pressure switch error code causing intermittent operation. Found plugged pressure switch hose, cleared obstruction and restored proper pressure sensing. Performed comprehensive system inspection with all components verified in specification. Unit now functioning properly with normal heating operation.
Diagnosed LP furnace failure showing pressure switch error code. Upon inspection, identified significant cracks on burner face plate and confirmed a substantial hole in the heat exchanger passageways via camera inspection. Customer declined both heat exchanger replacement and service advisor visit, indicating they would pursue furnace replacement with another provider.
Inspected 21-year-old natural gas furnace reporting intermittent heat. Diagnosed weak flame code and cleaned dirty flame sensor. Further inspection revealed multiple perforations at the primary-to-secondary heat exchanger junction, which were visually confirmed with the homeowner. Due to compromised heat exchanger integrity, recommended complete system replacement and scheduled consultation for same-day quote.