with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Winter in Spring Valley brings long stretches of icy mornings and deep cold. Our team keeps your home warm with detailed heating services tailored to local weather. We work with furnaces, boilers, and heat pumps, ensuring dependable performance through each freeze. Whether you need a quick repair, a complete system replacement, or seasonal maintenance, we have you covered.
Many homeowners reach out for heating repair in Spring Valley when they notice uneven heat, rising energy use, or systems struggling to keep up. We diagnose issues quickly and offer solutions that fit your home’s layout and usage patterns. Our goal is to maintain dependable heat without disrupting your household. With Hurlburt, you always get honest guidance and steady results with emergency HVAC in Spring Valley.
When summer humidity arrives in Spring Valley, a dependable cooling system becomes essential. We support homeowners with AC installation, maintenance, and repair in Spring Valley, WI. Whether your system struggles to cool rooms evenly or shuts off unexpectedly, we provide solutions that help you stay comfortable through the warmest months.
Our AC repair in Spring Valley, WI addresses airflow problems, worn components, and system imbalances. These issues not only affect your comfort but also the indoor air quality in Spring Valley, WI. We take the time to understand how your home responds to heat and humidity and provide cooling options that improve comfort and efficiency.
Your plumbing system plays a major role in your home’s safety and convenience. We keep your water flowing with repair and installation services delivered by our trained plumbers in Spring Valley, WI. If you deal with leaks, low pressure, or fixture issues, we diagnose the cause and restore function efficiently.
Whether you plan a fixture upgrade or need quick help with a stubborn problem, you can rely on our professional plumbers in Spring Valley, WI. We treat your home with care and ensure every part of your system operates smoothly.
Safe electrical systems protect your home and family. Our electricians handle repairs, replacements, and upgrades that keep your home operating smoothly. If you notice flickering lights, outdated wiring, or unreliable outlets, you need an electrician in Spring Valley, WI.
We support remodels that involve electrical upgrades. Our electricians in Spring Valley, WI, work with precision and follow current safety standards, ensuring every project meets expectations.
Spring Valley is a tight-knit community where neighbors look out for one another. Whether you live near the Crystal Cave entrance or closer to the Eau Galle Recreation Area, you rely on dependable home systems. Our team understands the area’s unique traits, including heavy snowfalls, damp river air, and warm summer nights. We tailor our services to meet these local demands, supporting homeowners with reliable HVAC, plumbing, and electrical services.
We work throughout the village, helping homes of all sizes stay safe and efficient. When storms roll through Pierce County or temperatures fluctuate rapidly, we provide steady support.
For more than 65 years, Hurlburt has proudly served customers throughout Minnesota. We deliver reliable service backed by strong values and a commitment to excellent workmanship. With over 6,000 5-star reviews, we prove our commitment to the Spring Valley community.
When you work with us, you become a part of the family. Welcome to the Hurlburt Family! We are always here to take your call and ready to help your home stay comfortable and safe.
Contact Hurlburt today to schedule services for your HVAC in Spring Valley. We’re here when you need HVAC, plumbing, or electrical services for your home.
Removed and disposed of a corroded and leaking hot water recirculation pump from the residential water heater system. Installed a new Grundfos recirculation pump with timer control, ensuring all connections were properly secured to existing piping infrastructure. Bled all hot water lines throughout the system to remove air pockets and verified proper circulation and pump operation. During inspection, identified a corroded nipple fitting on the water heater outlet that will require future monitoring and potential replacement. Tested the complete system for leaks and confirmed the new pump was cycling correctly according to timer settings. Installation includes a 1-year parts and labor warranty. Customer was advised of the corroded fitting condition but declined additional repairs at this time.
Responded to no cooling condition on 5-year-old heat pump system. Upon inspection, discovered rodent damage to compressor wiring causing high amperage draw and system failure. Repaired damaged wiring where possible and restored cooling operation. Performed routine maintenance including condenser coil cleaning, condensate drain clearing, and provided replacement air filter. Identified crankcase heater wiring damaged beyond repair due to rodent activity at connection point near heater element, requiring full crankcase heater replacement. System tested and operational with cooling restored, pending crankcase heater replacement recommendation.
Responded to a water heater recirculation pump leak on a Hydropro tanked water heater system. Upon inspection, discovered extensive corrosion and mineral deposits around the pump connections and mounting base, indicating a prolonged slow leak that had compromised the unit's integrity. Assessed the circulation pump assembly and associated piping connections, documented the corrosion damage with photographs, and ordered the appropriate replacement recirculation pump to restore proper system operation and eliminate the leak.
Responded to a continuous leak underneath the kitchen sink. Upon inspection, identified a cracked section of CPVC cold water supply line and a leak in the drain piping assembly. Replaced the damaged section of the cold water line and installed a new section of drain piping to eliminate both leak sources. Verified all connections were secure and tested the system to confirm proper operation with no further leakage.
Performed extensive leak search on mini split system that was previously serviced three years ago with refrigerant charge and UV dye addition. System found completely flat on refrigerant due to customer not scheduling follow-up leak check as recommended. Conducted thorough UV light inspection of indoor unit evaporator coil, drain pan, and refrigerant connections to locate source of refrigerant loss. UV dye traces examined under ultraviolet illumination revealed leak indicators in drain pan area and internal components. Provided second opinion regarding proper use of UV dye in refrigerant systems, confirming that UV dye is an approved leak detection method when used with compatible refrigerants and in accordance with manufacturer specifications.
Installed new exterior faucet on front of garage by routing copper jumper line from existing garage spigot through brick wall, as direct house penetration was not feasible due to brick construction. Replaced leaking stem on existing garage faucet. All connections tested and verified leak-free with proper operation confirmed.
Responded to no cooling complaint on air conditioning system over 10 years old. Diagnosed failed dual capacitor preventing compressor from operating properly. Replaced defective dual capacitor with new unit, tested system operation with multimeter to verify proper capacitance readings, and confirmed system cooling normally upon departure.
Returned call to address customer questions regarding estimates provided during previous visit. Reviewed proposed work scope and specifications with customer, clarifying details about HVAC furnace system and electrical panel requirements. Documented existing conditions through photography, capturing current furnace installation with PVC exhaust/intake configuration and electrical distribution panel with multiple circuit breakers. Answered all customer inquiries and confirmed customer's intent to proceed with recommended work upon completion of discussion.
Replaced defective temperature sensor wiring harness on HVAC unit under full warranty coverage. After installation, performed system testing to verify proper operation and confirmed unit is cooling correctly.
Responded to a tub leaking issue affecting the basement below. Upon inspection, identified a faulty shower valve and compromised tub drain assembly as the sources of water intrusion. Documented existing conditions with photographs of the bathtub fixtures and accessible plumbing in the basement/crawl space area. Provided detailed estimates for complete replacement of the defective shower valve and tub drain to resolve the ongoing leak.
Responded to no cooling complaint on 10+ year old HVAC system with suspected electrical issues. Found severely plugged air filter restricting airflow to the system. Replaced filter, performed complete AC service including condenser coil cleaning, and verified proper operation of all electrical components and system functionality. Measured system parameters and confirmed unit returned to normal cooling operation with adequate airflow and proper refrigerant pressures.
Responded to a bathtub drain that was completely non-functional due to a severely clogged custom drum trap. Upon inspection in the basement utility area, found the existing drum trap was plugged solid and beyond cleaning. Removed the obsolete drum trap assembly and replaced it with new Schedule 40 PVC trap configuration to restore proper drainage and meet current plumbing code standards.
Responded to gas leak detected by LP supplier at boiler fitting in basement. Upon inspection, discovered union connection and multiple gas piping fittings were inadequately tightened from original installation approximately three years prior. Applied pipe dope and properly torqued all gas line connections including unions, valves, and fittings on the IBC boiler system. Verified all connections were secure and gas-tight. System supplies radiant floor heating to basement area, with LP supplier having shut off valve to affected line as precautionary measure prior to arrival.
Responded to no cooling call on heat pump system installed last October. Upon inspection, discovered rodent damage to temperature sensor wiring at outdoor unit, preventing outdoor section from operating. Attempted field splice repair of damaged sensor wires to restore immediate cooling function, but splice was unsuccessful in reestablishing proper communication between outdoor unit and system controls. Documented wiring damage and recommended full wiring harness replacement to properly restore system operation.
Responded to no cooling complaint on 19-year-old air conditioning system. Upon arrival, verified thermostat call for cooling and inspected indoor unit. Found air filter in acceptable condition and tested blower motor capacitor, which measured 30% below rated specifications. Proceeded to outdoor condensing unit and connected refrigerant gauges to service ports. Diagnostic testing revealed critically low refrigerant charge with near-zero suction pressure readings. Visual inspection of outdoor coil showed significant dirt and debris accumulation on condenser fins. Due to system age and HCFC-22 refrigerant type, recommended customer consultation with service advisor regarding repair versus replacement options, as company policy does not support recharging legacy refrigerant systems.
Completed comprehensive AC tune-up on 21-year-old HVAC system as part of recurring maintenance agreement. Performed outdoor unit coil washing, electrical testing, and system diagnostics with all measurements within manufacturer specifications and achieving proper temperature differential. System operating properly with no deficiencies noted.
Completed annual plumbing inspection with emphasis on water heater evaluation. Inspected bathtub drainage system including trip waste assembly and overflow components, which are functioning properly. Examined under-sink plumbing including P-trap configuration and drainage lines with no leaks detected. Assessed 20-year-old water heater installed in 2005 and determined unit has exceeded typical service life expectancy. Prepared estimate for water heater replacement due to age and potential reliability concerns.
Completed routine AC maintenance tune-up on a 15-year-old system that was functioning properly prior to service. Replaced air filter and performed thorough cleaning of outdoor condenser coil, which had accumulated significant dirt and debris. Conducted system diagnostics with multimeter to verify proper electrical operation and overall performance before the cooling season.
Responded to emergency call for shower valve that would not shut off, requiring main water supply to be turned off at the house. Upon inspection, found a failed cartridge and a stripped handle that could not be removed through conventional methods. Extracted the damaged cartridge by disassembling it in sections and cut off the seized handle to access the valve body. Installed new cartridge and complete trim kit for the shower valve, restoring full operational control. Tested system to verify proper hot and cold water mixing and complete shutoff functionality.
Responded to no heat call and found communication failure between S30 thermostat and E30 smart hub. Upon investigation, discovered the E30 communicating control board was installed on a non-communicating furnace, creating a system mismatch. Identified that the S30 thermostat with magnetic mount was not properly seated on the mount, preventing proper communication with the hub. Repositioned thermostat on magnetic mount and performed system reset, restoring full functionality. Verified heating operation and confirmed system communication was re-established. Discussed findings with homeowner regarding the equipment compatibility concerns and recommended exploring options for either a non-communicating T10 thermostat or an updated communicating thermostat model to improve system reliability. Submitted part order form to verify warranty coverage and obtain pricing for potential thermostat replacement options. System restored to full operation at time of departure.