Winter in Spring Valley brings long stretches of icy mornings and deep cold. Our team keeps your home warm with detailed heating services tailored to local weather. We work with furnaces, boilers, and heat pumps, ensuring dependable performance through each freeze. Whether you need a quick repair, a complete system replacement, or seasonal maintenance, we have you covered.
Many homeowners reach out for heating repair in Spring Valley when they notice uneven heat, rising energy use, or systems struggling to keep up. We diagnose issues quickly and offer solutions that fit your home’s layout and usage patterns. Our goal is to maintain dependable heat without disrupting your household. With Hurlburt, you always get honest guidance and steady results with emergency HVAC in Spring Valley.
When summer humidity arrives in Spring Valley, a dependable cooling system becomes essential. We support homeowners with AC installation, maintenance, and repair in Spring Valley, WI. Whether your system struggles to cool rooms evenly or shuts off unexpectedly, we provide solutions that help you stay comfortable through the warmest months.
Our AC repair in Spring Valley, WI addresses airflow problems, worn components, and system imbalances. These issues not only affect your comfort but also the indoor air quality in Spring Valley, WI. We take the time to understand how your home responds to heat and humidity and provide cooling options that improve comfort and efficiency.
Your plumbing system plays a major role in your home’s safety and convenience. We keep your water flowing with repair and installation services delivered by our trained plumbers in Spring Valley, WI. If you deal with leaks, low pressure, or fixture issues, we diagnose the cause and restore function efficiently.
Whether you plan a fixture upgrade or need quick help with a stubborn problem, you can rely on our professional plumbers in Spring Valley, WI. We treat your home with care and ensure every part of your system operates smoothly.
Safe electrical systems protect your home and family. Our electricians handle repairs, replacements, and upgrades that keep your home operating smoothly. If you notice flickering lights, outdated wiring, or unreliable outlets, you need an electrician in Spring Valley, WI.
We support remodels that involve electrical upgrades. Our electricians in Spring Valley, WI, work with precision and follow current safety standards, ensuring every project meets expectations.
Spring Valley is a tight-knit community where neighbors look out for one another. Whether you live near the Crystal Cave entrance or closer to the Eau Galle Recreation Area, you rely on dependable home systems. Our team understands the area’s unique traits, including heavy snowfalls, damp river air, and warm summer nights. We tailor our services to meet these local demands, supporting homeowners with reliable HVAC, plumbing, and electrical services.
We work throughout the village, helping homes of all sizes stay safe and efficient. When storms roll through Pierce County or temperatures fluctuate rapidly, we provide steady support.
For more than 65 years, Hurlburt has proudly served customers throughout Minnesota. We deliver reliable service backed by strong values and a commitment to excellent workmanship. With over 6,000 5-star reviews, we prove our commitment to the Spring Valley community.
When you work with us, you become a part of the family. Welcome to the Hurlburt Family! We are always here to take your call and ready to help your home stay comfortable and safe.
Contact Hurlburt today to schedule services for your HVAC in Spring Valley. We’re here when you need HVAC, plumbing, or electrical services for your home.
Hurlburt Heating & Plumbing has completed 20 jobs in Spring Valley, WI between August 2026 and October 2026.
The most recent job was on October 15, 2026.
Hurlburt Heating & Plumbing has completed 89 jobs in Spring Valley, WI in the last 12 months. The first job there was in May 2016.
Performed annual maintenance and tune-up on a 13-year-old furnace, which was found to be in good condition for its age. Inspected the control board and wiring and noted a frayed loose wire end near the lower portion of the board. Used a borescope to inspect the blower wheel, which showed early debris buildup, and cleaned the blower wheel to restore proper airflow.
Responded to a wall-mounted urinal that ran continuously and required the water supply to be shut off to stop it. Diagnosed the chrome flush valve as worn and at end of life, causing the constant running. Submitted a parts order for a replacement urinal flush valve.
Performed comprehensive furnace inspection on 26-year-old Lennox G26 unit to assess compatibility prior to planned air conditioning system replacement. Conducted thorough electrical component testing with all readings within manufacturer specifications. Inspected heat exchanger for cracks or deterioration—found in good condition with no concerning issues despite age of equipment. Cleared partially plugged condensate drain line and verified proper drainage. Completed operational test run confirming proper heating function and system performance. Advised that while furnace is currently operational and passed inspection, age of unit warrants consideration for replacement concurrent with AC installation to avoid future compatibility issues or premature failure.
Completed comprehensive furnace tune-up on forced air heating system. Performed standard maintenance procedures per checklist, including inspection of evaporator coil, heat exchanger, and all major components. Unit was found to be in good operating condition with no deficiencies noted.
Completed comprehensive geothermal system maintenance on a 3-year-old unit, including routine testing of all components, bleeding air from the loop field, and verifying proper operation of the infloor heating system. Investigated customer concerns regarding potential animal damage to exterior equipment box and unusual noise when unit was moved. All equipment tested and verified to be operating within normal parameters following maintenance procedures.
Responded to report of water leak from upstairs bathroom area penetrating ceiling and affecting kitchen light fixture below. Systematically tested all upstairs plumbing fixtures including four vanity sinks, two showers, two toilets, and laundry connections by running water down each drain for extended periods. Inspected floor areas around toilets and beneath vanities for standing water or active leaks. Unable to replicate the reported leak condition during service visit. Customer indicated that shower curtain may not have been properly positioned inside tub during recent use, potentially allowing water to escape onto floor and seep through to ceiling below, which is consistent with the intermittent nature of the leak and lack of visible plumbing defects found during inspection.
Responded to no heat call on 10-year-old Lennox Elite furnace (Model C-33-258-2-6, Serial 6017A30922). Diagnosed blower motor as locked up and inoperative, preventing air circulation through the system. Submitted parts order form for blower motor replacement and documented equipment condition with photos of internal components and ductwork.
Completed routine heating maintenance on 21-year-old furnace system in duplex unit. Inspected gas valve assembly, verified all electrical connections, checked combustion components, and replaced air filter. Noted inducer motor producing excessive noise during operation and recommended draft motor replacement; comfort advisor scheduled for follow-up assessment of aging system.
Completed comprehensive preventive maintenance on a 5-year-old Lennox furnace system. Performed standard tune-up procedures including filter inspection, burner cleaning, ignition system check, blower motor lubrication, and safety control verification as documented on tune-up checklist. All equipment tested and operating within normal parameters.
Completed scheduled heating maintenance as part of recurring service agreement. Performed comprehensive furnace inspection including operational test, temperature rise verification, heat exchanger inspection, and lower compartment examination. Replaced heavily soiled air filter that had not been changed in approximately five months. Cleaned flame sensor and inspected igniter for proper operation. Cleared condensate drain lines and verified pressure switch ports were free of obstructions. All system components tested and confirmed operating within normal parameters. Recommended more frequent filter changes to maintain optimal system performance and efficiency.
Performed scheduled maintenance tune-up on FRP boiler system operating as secondary heating source to geothermal system. Inspected all routine boiler components and confirmed all readings within manufacturer specifications. Flushed condensate trap, removed and cleaned flame sensor and igniter assembly—all components found clean and operating properly. System shows minimal runtime due to secondary operation in conjunction with primary geothermal unit and is functioning as designed.
Completed annual plumbing inspection and addressed kitchen faucet flow issue caused by sediment buildup in the aerator head. Removed and cleaned aerator, restoring proper water pressure and flow. Inspected basement plumbing and noted green discoloration on pipes consistent with high pH water conditions; confirmed water softener is functioning correctly. All plumbing fixtures and systems operating within normal parameters.
Completed preventive maintenance tuneup on geothermal heating and cooling system. Inspected and tested all system components, verified refrigerant pressures and operating temperatures were within manufacturer specifications, and confirmed unit functioning properly. Identified non-operational Carrier heat recovery ventilator and humidifier that require removal. Customer reported mold growth on interior surfaces, likely due to excessive indoor humidity levels and inadequate air circulation. Recommended installation of standalone whole house dehumidifier in basement with dedicated return air duct connection to work in conjunction with continuous fan operation on geothermal system to address moisture issues throughout home. Gathered equipment information for account records and advised customer on proper filtration requirements for system. Customer to schedule follow-up appointment for dehumidifier installation estimate and removal of non-functional ventilation equipment.
Responded to a water leak originating from an upstairs toilet that was leaking from the base and causing damage to the basement below. Removed and replaced the failed toilet with a new Gerber unit, ensuring proper wax ring seal and secure mounting to prevent future leaks. Additionally addressed two dripping bathroom vanity faucets by installing new Moen lavatory faucets with chrome finish and porcelain handles. All fixtures were tested for proper operation and verified leak-free upon completion.
Responded to no cooling complaint on aging outdoor condensing unit. Homeowner reported intermittent buzzing sound when system was called for cooling, followed by unit going quiet with no fan operation. Performed electrical diagnostics and identified failed dual run capacitor preventing compressor and condenser fan motor from starting. Discussed findings with homeowner who authorized capacitor replacement. Installed new capacitor, verified proper voltage and amperage readings on compressor and fan motor, and tested all electrical components for proper operation. Performed courtesy condenser coil rinse to remove debris and improve heat transfer efficiency. Cycled system through complete cooling cycle and confirmed outdoor unit now operating properly with normal cooling restored to home.
Responded to callback for AC2 error code on recently installed thermostat with no cooling operation. Found thermostat calling for cooling but equipment not responding and displaying AC2 fault. Performed system reset and connected to equipment via CoolCloud HVAC application. Updated control board firmware and verified all system settings and parameters. Cycled system through complete cooling operation to confirm proper communication between thermostat and equipment. All components now functioning correctly with no fault codes present.
Responded to no cooling complaint on 27-year-old R22 system. Diagnosed low refrigerant charge, weak dual capacitor, and heavily pitted contactor. Replaced dual capacitor and contactor to restore electrical functionality. Due to system age, R22 refrigerant phase-out, and extent of wear, recommended comfort advisor consultation for replacement options.
Responded to exterior faucet leak that had been dripping constantly for approximately three weeks. Upon inspection, determined that the outside faucet required complete replacement due to continuous water loss. Additionally identified that the main water shutoff valve was also leaking and inoperable, preventing proper isolation of the exterior fixture. Shut down water supply at the basement main line to facilitate repairs. Successfully installed new exterior faucet and replaced the failed main water valve. Both fixtures tested and confirmed operational with no leaks upon restoration of water service.
Performed annual air conditioning maintenance on 27-year-old R22 system. Upon inspection, identified failed dual capacitor and compromised heat exchanger. Replaced dual capacitor to restore proper compressor and fan motor operation. Scheduled comfort advisor consultation due to heat exchanger failure requiring system evaluation for replacement options given age and refrigerant phase-out considerations.
Completed comprehensive furnace tune-up and maintenance inspection. Tested full furnace operation including second stage heating, verified air filter condition, cleaned flame sensor, and cleared condensate drain line. Addressed irregular line voltage code on control board related to recent power outages and cleared fault from system. All components inspected and verified operational, with homeowner advised on ongoing filter maintenance schedule.