We’ve assisted homeowners for over 65 years and will proudly service your home as well.

Replacing or fixing a defective or aging heating unit can help keep your home warm throughout the extremely cold winter season. We’re here to make sure your heating system works the way it should, keeping every room in your home warm, comfortable, and energy-efficient without the hassle.
Discover Our Numerous Heating Services for Your Home:
- Heating Repair: If your furnace is constantly cycling or making odd noises, we can help fix those issues. We’ll also fix thermostat issues, gas leaks, or other problems that can put you and your home in danger.
- Heating Installation: Putting a new furnace in your home can save money on utility bills and keep maintenance and repairs to a minimum for up to 20 years. We’ll make sure to install your new system promptly and properly.
- Heating Maintenance: Regular cleanings and inspections can minimize the risk of furnace damage while also improving indoor air quality. The Hurlburt Family Rewards Program can make it easier to get the service you need to protect your investment for years to come.
If your cooling system is more than a decade old and has started to experience issues, it may be time to consider replacing it. We can also fix any minor issues that your system might have, as well as provide routine maintenance to help your air conditioner last for the entirety of its useful life.
Contact Our Team for Great Cooling Services:
- Cooling Repair: When you see moisture near the condenser unit or feel warm air coming out of a vent, it’s time to give us a call. We’ll diagnose the issue quickly to ensure that you can watch TV, sleep, or otherwise enjoy being at home.
- Cooling Installation: A new cooling system is easier to maintain, as older units require parts and coolant that technicians might not readily have available. You’ll also likely save money on cooling bills as well as on maintenance costs for years to come.
- Cooling Maintenance: You should have our technicians inspect your air conditioner at least once a year, either during the spring or fall season. Doing so can prevent unexpected shutdowns or other issues in keeping your home cool. Our Hurlburt Family Rewards Program helps you save on maintenance and more!
A slab leak, clogged toilet or burst pipe can cause a multitude of problems, such as mold growth or a cracked foundation. You may also see increased water bills if a pipe is broken or leaking. Our team can diagnose virtually any kind of plumbing issue to ensure that your home’s pipes and fixtures are working just as they should.
An appliance that overheats when in use might be a sign that your electrical panel needs an upgrade. We can take care of that quickly. We can also fix a frayed wire or take care of other electrical issues. If you’re in need of a trusted Savage electrician, we’re the team to call!
Make an Appointment Today With Our Electricians for:
- Electrical Repair: An exposed or chewed wire might short and possibly cause an electrical fire. Our team will take care of that and other existing problems quickly to prevent any secondary problems from occurring.
- Electrical Installation: Replacing old wires can make your home safer and better suited to modern electrical consumption habits. Putting in a whole home generator, EV charger, or new electrical panel can also make it easier to meet your needs.
Whether we’re installing a whole home generator in a Summit Pointe Park home or a new cooling system in a Hidden Valley Park home, we love serving our community. We’ll be more than happy to take a trip down Highway 13 or County Road 42 to meet you and learn how we can help meet your plumbing, electrical, and HVAC needs.
With our range of HVAC service offerings, as well as plumbing and electrical services, we can help everyone in our community. Having access to timely repair, maintenance, and installation services means that you can fix or otherwise take care of a problem before it has the chance to wreak too much havoc on your home. Remember, we treat everyone like a member of our family. Our goal is to ensure you get great service at an affordable price.
When you need help from an HVAC company, electrician, or plumber in Savage, give our team at Hurlburt a call today!
Hurlburt Heating & Plumbing has completed 20 jobs in Savage, MN between May 2026 and June 2026.
The most recent job was on June 16, 2026.
Hurlburt Heating & Plumbing has completed 165 jobs in Savage, MN in the last 12 months. The first job there was in April 2025.
Installed single-bulb UV light system above the evaporator coil to improve indoor air quality and reduce microbial growth. Cut access opening in ductwork, mounted UV light unit with blue illuminated bulb, and completed electrical connections to ensure proper operation.
Responded to a water leak complaint in an upstairs guest bathroom where a slow drip was occurring from the tub spout. Upon inspection, diagnosed a faulty Moen cartridge as the source of the leak. Removed and replaced the defective cartridge, resolving the dripping issue and restoring proper function to the shower fixture.
Replaced copper water supply valve with new plastic push-fit shut-off valve for dishwasher installation. Cut existing copper line and installed new stop valve to accommodate appliance connection. Verified proper shut-off operation and checked for leaks upon completion.
Installed electrical relay to outdoor HVAC unit for energy monitoring system integration with existing load shed device. The relay component features a multi-terminal connection grid designed to interface between the metering equipment and the condensing unit, allowing proper communication for energy management purposes. Installation completed as specified for system functionality.
Completed comprehensive AC tune-up on 14-year-old residential cooling system. All components tested within manufacturer specifications, refrigerant charge verified at proper levels, and system operational performance confirmed. Outdoor condenser coils found heavily soiled requiring full disassembly for thorough cleaning to restore optimal heat transfer efficiency and extend equipment lifespan. Identified air-restrictive furnace filter (high MERV rating) limiting airflow; recommended switching to MERV 7-8 rated filter with monthly replacement schedule to improve system performance and reduce strain on blower motor.
Responded to a non-functioning outdoor hose spigot that would not shut off. Upon inspection, determined that internal seals were worn out and the spigot had corroded to the point where it could not be removed using conventional methods. Due to severe corrosion preventing the spigot from being unscrewed from the exterior, accessed the connection point by cutting an access hole in the interior wall behind the fixture. Removed the deteriorated spigot assembly from the interior access point. Installed a new hose spigot, properly securing it to the exterior siding with appropriate mounting hardware. Tested the new spigot for proper operation, confirming smooth on/off functionality and verified no leaks were present at the connection points or valve body.
Replaced a failing water control valve up to 1" on the plumbing system. The existing gate valve was no longer functioning properly to control water flow through the line. Installed a new ball, gate, swing, spring, or check valve assembly as needed to restore proper water flow control. The replacement valve was mounted on the copper piping system with brass threaded fittings and connectors, secured to the wooden backing board. Verified proper operation of the new valve and confirmed no leaks at connection points. The repair successfully restored reliable water flow control capability to the system.
Responded to no cooling call on 24-year-old air conditioning system. Found failed fuses in outdoor disconnect, which were replaced to restore power to the condenser unit. Condenser fan motor required manual rotation to initiate operation, indicating failing motor bearings or capacitor issues. System returned to operational status as a temporary repair with no guarantee due to age and condition of equipment. Replaced dirty air filter during service. Scheduled system replacement estimate due to advanced age and deteriorating components that make further repairs inadvisable.
Responded to service call for multiple plumbing concerns including malfunctioning shut-off valves and leaking fixtures. Accessed crawl space to locate and replace defective shut-off valve serving exterior hose bib that was failing to stop water flow when closed. Replaced old, worn valve with new brass shut-off valve and verified proper operation. Replaced leaking exterior spigot with new frost-free hose bib. Inspected utility sink faucet and main water shut-off valve as requested, assessed condition and provided recommendations. All replaced components tested for proper function and leaks. Work completed in attic/crawl space area with copper pipe connections secured and system restored to full operation.
Responded to service call for leaking lavatory faucet and malfunctioning shut-off valves. Upon inspection, determined that both shut-off valves under the sink were leaking and failed to properly isolate water flow, creating potential emergency access issues. Removed existing deteriorated shut-off valves and supply lines from copper stub-outs. Installed new BrassCraft quarter-turn angle stop valves with oval handles on both hot and cold water lines. Connected new braided stainless steel flexible supply lines from the angle stops to the lavatory faucet connections. Verified all connections for proper seal and tested valve operation to ensure complete water shut-off capability. Checked for leaks under pressure and confirmed system integrity. Cleaned work area and removed all debris. All components now functioning properly with reliable water isolation capability restored.
Responded to complaint of chemical odor in laundry room area. Conducted comprehensive diagnostic inspection of all drain lines, cleanout caps, and visible plumbing fixtures with no leaks or drainage issues identified. All drains tested and confirmed flowing properly. Investigated sump pump system and discovered pump basin was dry and hot to touch with noticeable odor present. Found sump pump had been improperly wired directly to electrical outlet, bypassing the float switch mechanism, causing unit to run continuously. Tested sump pump operation by introducing water to basin; pump failed to activate, confirming motor burnout. Determined burnt motor from continuous operation was likely source of odor, though homeowner indicated this was not the same chemical smell originally reported. Provided estimate for complete sump pump replacement to restore proper functionality and prevent future issues. Unable to definitively identify source of reported paint thinner odor during visit.
Responded to no hot water complaint on AO Smith gas water heater with recurring control valve failures. Customer had previously replaced gas control valve three times under warranty. Performed diagnostic evaluation to determine root cause of repeated gas valve failures. Inspected flame sensor for contamination, corrosion, or improper positioning that could cause false flame detection signals leading to premature gas valve failure. Examined burner assembly, combustion chamber, and venting system for proper operation. Documented condition of current gas control valve and flame sensor assembly with photos showing filter/sensor element with visible soiling and debris accumulation in lower section, indicating potential combustion air quality issues contributing to component failures.
Replaced defective pressure reducing valve on residential water system. Initial water pressure measured at 110 PSI, which exceeded safe operating parameters for household plumbing fixtures and appliances. Installed new PRV and adjusted settings to reduce system pressure to 75 PSI, establishing proper fill pressure and protecting the plumbing system from excessive strain.
Responded to water leak at main meter assembly. Upon inspection, identified active leak at meter horn connection with deteriorated gasket. Multiple valves in the assembly showed significant corrosion and rust buildup, indicating age and exposure to moisture. Replaced failed gasket at meter horn to resolve leak. Documented condition of corroded brass fittings and yellow-handled shut-off valves throughout vertical pipe assembly for future maintenance reference.
Responded to exterior water leak at outside faucet connected to irrigation system. Upon inspection, found hose bib attachment loose and a 1-inch press ball valve that had failed and blown apart. Tightened the loose hose bib connection and repaired the 1-inch press coupling to restore proper function and eliminate the leak.
# Annual Cooling System Maintenance Performed comprehensive annual cooling maintenance visit on residential HVAC system. Conducted thorough inspection of evaporator coil and indoor furnace, confirming stable temperature readings throughout. Evaluated all electrical components, including capacitors and contactor, which tested within acceptable parameters. Inspected outdoor condenser unit and found heavy accumulation of cottonwood debris and dirt buildup requiring attention. Cleaned accessible areas and documented condition for ongoing maintenance tracking. Performed refrigerant analysis and pressure testing. Readings indicate the system appears to be overcharged beyond manufacturer specifications. Upon investigation, installation documentation was unavailable, and the original installer could not be verified. Unable to confirm whether installation was completed by licensed HVAC contractor or unlicensed technician. Due to uncertainty regarding installation quality and proper procedur
Responded to service call for reported water heater leak on 75-gallon unit approximately 2 years old. Upon inspection, determined the water heater itself was not leaking. Identified failed dielectric union as the source of water leakage. Replaced defective dielectric union with new component and verified system integrity. Unit covered under parts warranty.
Responded to a water leak originating from a failing isolation valve located in the ceiling above the laundry room. Upon inspection, determined the valve required replacement along with the shower valve cartridge and tub spout. Successfully replaced the Moen Posi-Temp cartridge in the shower valve assembly and installed a new brushed nickel tub spout, resolving all leak issues and restoring proper function to the bathroom plumbing system.
Completed comprehensive furnace inspection and system evaluation on residential HVAC unit over 15 years old that was struggling to maintain adequate heating capacity. Performed standard tune-up procedures and diagnostic assessment to determine system condition and performance issues. Upon inspection, identified multiple deficiencies requiring attention: aging furnace showing signs of decreased efficiency and inadequate heating output, insufficient return air ductwork on upper level causing poor air circulation and system imbalance, lack of air exchanger for proper ventilation, and overall ductwork system in need of professional cleaning. Documented existing conditions through photographs showing current return air configuration in upper level area and basement/crawlspace infrastructure including existing ductwork, plumbing, and utility components. Based on findings, recommended complete furnace replacement due to age and performance limitations, installation of additional return air
Responded to service call for chemical odor resembling paint thinner in residence. Conducted thorough inspection of furnace system and evaporator coils, finding no evidence of refrigerant leaks or foreign objects lodged in blower wheel assembly. All HVAC components operating within normal parameters with no visible signs of damage or malfunction. Recommended plumbing inspection of floor drain line and sump pump as potential source of odor, as HVAC system ruled out as cause.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.