Our team provides installation, maintenance, and repair services for furnaces, boilers, and heat pumps. We can also help you achieve better indoor air quality in Roberts, WI. We install and service CO detectors, humidifiers, air purifiers, and much more.
Our summers are relatively mild, but it still gets hot and humid enough that you need reliable cooling. We handle everything from energy-efficient upgrades to emergency HVAC services for Roberts homes. Our technicians specialize in both central systems and ductless mini-split systems.
Our plumbing team provides the local expertise you need. We know how to upgrade a home to protect it from the area’s hard water. Our plumbers reduce water usage, optimize water heater efficiency, and much more.
Our electricians handle everything from rewiring old houses to optimizing new homes with sophisticated systems. Our rewiring services include replacing outdated components, such as aluminum and knob-and-tube wiring.
Our team provides home services all around Roberts Village Park. It’s the heart of local gatherings and the site of Good Neighbor Days, a beloved annual festival. This is an area where many houses date back to the 1990s and earlier. We help homeowners with older houses achieve efficient heating and cooling and better indoor air quality in Roberts, WI. Our electricians in Roberts, WI upgrade electrical panels and other aspects of residential electrical systems. Our plumbers in Roberts, WI can help you improve your plumbing system as well. That includes lowering your water consumption and protecting against the region’s hard water.
Our company provides HVAC, plumbing, and electrical services throughout St. Croix County and the surrounding areas. We have over 65 years of experience and deliver excellent customer service. We now have over 6,000 5-star reviews. You can schedule appointments with us online or by phone. Same-day appointments are available for urgent issues, and we have team members on call for emergencies. For installations, we offer free quotes and financing on approved credit. We also encourage you to learn more about our Family Rewards Club. Membership can save you big on home maintenance in the years ahead.
Hurlburt is a local, trusted choice for plumbing, electrical, heating, and cooling in Roberts, WI. Call today or contact us online to schedule an appointment.
Hurlburt Heating & Plumbing has completed 20 jobs in Roberts, WI between April 2026 and July 2026.
The most recent job was on July 15, 2026.
Hurlburt Heating & Plumbing has completed 93 jobs in Roberts, WI in the last 12 months. The first job there was in May 2018.
Responded to emergency gas leak at exterior fitting serving fireplace and pool heater. Upon arrival, utility company had shut off main gas meter to residence due to leak on unvalved line. Verified leak at flare fitting which was hand-tight with compromised flare connection. Attempted tightening but flare remained defective. Due to spatial constraints at original location, installed new section of gas-tight line routed through fence to allow proper connection access. Completed installation, pressurized system, and performed leak check verification on all connections. Restored gas service to residence and relit water heater pilot light and one fireplace pilot successfully. Second fireplace pilot would not light, which homeowner confirmed is a pre-existing intermittent issue with that unit. Verified pool heater operation and confirmed all gas appliances functioning properly with no active leaks detected.
Responded to no cooling complaint on 4-year-old residential HVAC system unable to maintain setpoint below 79°F. Diagnosed refrigerant leak at evaporator coil requiring replacement. Found outdoor condenser coil completely blocked with debris and vegetation; performed coil cleaning to restore temporary airflow and heat transfer. System operational short-term but evaporator coil replacement needed immediately to prevent complete system failure.
Responded to service call for furnace inspection following home inspector's report of non-operational unit. Upon arrival, found furnace repeatedly tripping high limit switch. Performed comprehensive system diagnostics including airflow verification and gas pressure testing, both within manufacturer specifications. Conducted thorough heat exchanger inspection and identified failed secondary heat exchanger with significant corrosion and debris accumulation. Secondary heat exchanger failure causing inadequate heat extraction, resulting in excessive temperature buildup and high limit safety trips. Explained to property owner that blocked secondary heat exchanger preventing proper heat transfer and creating overheating condition. Given unit age of over 20 years and extent of heat exchanger deterioration, replacement recommended over repair. Tagged furnace out of service due to failed heat exchanger safety concern. Confirmed air conditioning system remains operational and isolated from heati
Responded to no cooling complaint on a 20+ year old Trane air conditioning system that had been inoperative for several weeks. Upon inspection, diagnosed a seized condenser fan motor preventing proper heat rejection from the outdoor unit. Replaced the failed condenser fan motor to restore system operation and scheduled comfort advisor consultation to discuss equipment replacement options given the age and condition of the unit.
Performed Family Rewards cooling maintenance visit on 12-year-old residential AC system. Discovered confirmed refrigerant leak with system operating at low pressure, resulting in inefficient cooling. Compressor amperage measured at 70.5A, exceeding nameplate RLA of 64.0A, indicating overload condition. Inspected capacitor and contactor during tune-up. Provided homeowner with repair estimate and scheduled comfort advisor visit for July 1 to assess repair versus replacement options.
Responded to mainline backup issue where previous augering and jetting attempts had failed to resolve the blockage. Deployed drain camera to locate and clear obstruction, successfully pushing blockage through the 4" main drain pipe. Verified complete clearance by running over 50 gallons of water through the system and confirming proper flow. Camera inspection revealed significant belly in the main drain line extending approximately 30 feet from the base of the stack, indicating back-pitched section requiring future repair. Recommended follow-up for permanent correction of the improperly sloped drain section to prevent recurring blockages.
Completed annual AC maintenance on 21-year-old R22 system. During inspection, discovered dual capacitor reading out of specification and contactor showing significant pitting on contact points. Replaced defective dual capacitor and contactor to restore proper system operation and prevent potential failure.
Responded to no cooling complaint on a 5-year-old residential air conditioning system. Upon arrival, confirmed indoor blower was operating but system was not producing cold air. Performed diagnostic inspection of outdoor condensing unit, testing compressor operation, contactor function, and capacitor performance with multimeter. Found failed run capacitor preventing compressor from starting. Replaced defective capacitor with proper replacement, verified all electrical connections, and cycled system through complete cooling operation. Confirmed proper refrigerant charge, measured temperature split at supply registers, and verified system returned to normal cooling operation.
Responded to no cooling complaint on 4-year-old Lennox air conditioning system. Upon inspection, found outdoor condenser unit with excessive dirt and debris accumulation on coil fins restricting airflow. Cleaned condenser coil and exterior components to restore proper airflow. Performed refrigerant charge verification and discovered system operating with low refrigerant levels, indicating potential leak or improper initial charge. Advised property owner that low refrigerant on relatively new equipment should be covered under manufacturer or installation warranty and recommended contacting original installing contractor for warranty service and proper refrigerant leak diagnosis.
Responded to no cooling complaint on 15-year-old Payne HVAC system. Upon arrival, confirmed system was running but not producing cool air. Performed diagnostic inspection including air filter check, blower verification, and airflow assessment—all within normal parameters. Inspected outdoor condenser coil, found minor debris accumulation, and performed light rinse to restore optimal heat transfer. Conducted refrigerant pressure test and identified system was significantly low on charge. After discussing repair options with homeowner, who indicated plans for system replacement within one year, proceeded with refrigerant recharge without leak detection dye service per customer request. Recharged system to manufacturer specifications, verified proper operation, and confirmed 22-degree temperature split across evaporator coil. System restored to normal cooling operation.
Replaced three standard height toilets with new units including wax rings, mounting bolts, and complete installation. Installed a 20-inch whole house sediment and rust filter with 1-inch inline connection to address excessive sand and sediment contamination affecting plumbing fixtures throughout the residence. Replaced one toilet shut-off valve and supply line to prevent future water damage and ensure proper emergency shut-off capability. All installations completed to manufacturer specifications with filter system designed to capture sediment, dirt, and rust particles, protecting fixtures from mineral damage and staining while improving water quality.
Responded to multiple toilet issues in units 8-12 where sediment accumulation in tanks caused fill valve malfunctions and gasket deterioration leading to bowl leakage. Installed two Mansfield gaskets as immediate repair solution. Documented conditions and completed parts order form for three replacement toilet units and sediment filtration system to be installed during follow-up visit later this week to address underlying water quality issue causing excessive mineral buildup.
Responded to a water leak under the bathroom sink caused by failed shut-off valve and deteriorated supply lines. Shut off water supply to the affected bathroom and removed the old, leaking components. Installed new shut-off valve and braided stainless steel supply lines, restoring full water service to the sink with no active leaks upon completion.
Responded to no cooling complaint on system older than 10 years with frozen refrigerant lines. Upon arrival, found outdoor condenser coil completely packed with debris restricting airflow. Performed thorough coil cleaning to restore proper airflow through condenser. After cleaning, verified system operation and measured pressures and temperatures. System equipped with TXV showed good temperature drop across evaporator coil. Pressures indicated slight overcharge on R-22 system, but left unchanged due to 20-year operational history without issues. Tested capacitor and found weak readings. Indoor air filter found in acceptable condition. System restored to cooling operation following coil cleaning.
Completed comprehensive air conditioning maintenance tune-up on a 7-year-old single unit system. Performed indoor inspection including filter check, blower assembly cleaning, and verified proper blower speed settings. Conducted outdoor unit evaluation with electrical component inspection, capacitor testing (all readings within manufacturer specifications), and wiring verification. Rinsed condenser coils, reassembled unit, and performed operational test confirming proper system performance with 22-degree temperature split across the evaporator coil.
Performed comprehensive AC tune-up on 30-year-old Tempstar R-22 system. Inspected outdoor unit components, rinsed condenser coil, verified blower wheel and evaporator coil cleanliness, and confirmed clean filter. During operational testing, discovered suction line freezing with low pressure reading of approximately 45 PSI, indicating significant refrigerant undercharge from previous service by another company. Scheduled service advisor for follow-up refrigerant evaluation and system diagnostics to address the R-22 charging issue.
Conducted on-site assessment to provide estimate for water meter hookup replacement in mechanical utility room. Inspected existing plumbing configuration including water heater connections, copper supply lines, and main water service entry point to determine scope of work required for meter hookup replacement.
Responded to no heat call with reported loud fan noise and error code 163 on S40 controller indicating refrigerant detection system alarm. Upon arrival, found furnace shut off with recurring fault history. Performed diagnostic inspection of S40 controller, furnace control board, and associated wiring connections. Verified refrigerant levels within specification and cycled system through operational sequence. Error cleared during diagnostic process, but identified faulty refrigerant sensor as root cause of intermittent alarm condition. Ordered replacement sensor to resolve recurring issue and prevent future nuisance shutdowns.
Responded to callback for water heater installed one month prior with reported air in water lines throughout the home. Systematically bled all fixtures and water lines in the residence, removing trapped air likely introduced during initial installation. Advised customer to monitor system performance and contact for further diagnostics if issue persists.
Responded to kitchen sink plumbing issues involving low hot water pressure and a leaking basket strainer. Removed and replaced the defective basket strainer with a new unit, ensuring proper seal and installation. Cleared debris from the hot water supply tube connected to the kitchen faucet, which was restricting flow and causing the reduced pressure. Tested both hot and cold water flow after repairs to verify proper operation and confirmed no leaks at the basket strainer or supply connections.