Our team provides installation, maintenance, and repair services for furnaces, boilers, and heat pumps. We can also help you achieve better indoor air quality in Roberts, WI. We install and service CO detectors, humidifiers, air purifiers, and much more.
Our summers are relatively mild, but it still gets hot and humid enough that you need reliable cooling. We handle everything from energy-efficient upgrades to emergency HVAC services for Roberts homes. Our technicians specialize in both central systems and ductless mini-split systems.
Our plumbing team provides the local expertise you need. We know how to upgrade a home to protect it from the area’s hard water. Our plumbers reduce water usage, optimize water heater efficiency, and much more.
Our electricians handle everything from rewiring old houses to optimizing new homes with sophisticated systems. Our rewiring services include replacing outdated components, such as aluminum and knob-and-tube wiring.
Our team provides home services all around Roberts Village Park. It’s the heart of local gatherings and the site of Good Neighbor Days, a beloved annual festival. This is an area where many houses date back to the 1990s and earlier. We help homeowners with older houses achieve efficient heating and cooling and better indoor air quality in Roberts, WI. Our electricians in Roberts, WI upgrade electrical panels and other aspects of residential electrical systems. Our plumbers in Roberts, WI can help you improve your plumbing system as well. That includes lowering your water consumption and protecting against the region’s hard water.
Our company provides HVAC, plumbing, and electrical services throughout St. Croix County and the surrounding areas. We have over 65 years of experience and deliver excellent customer service. We now have over 6,000 5-star reviews. You can schedule appointments with us online or by phone. Same-day appointments are available for urgent issues, and we have team members on call for emergencies. For installations, we offer free quotes and financing on approved credit. We also encourage you to learn more about our Family Rewards Club. Membership can save you big on home maintenance in the years ahead.
Hurlburt is a local, trusted choice for plumbing, electrical, heating, and cooling in Roberts, WI. Call today or contact us online to schedule an appointment.
Hurlburt Heating & Plumbing has completed 20 jobs in Roberts, WI between July 2026 and September 2026.
The most recent job was on September 2, 2026.
Hurlburt Heating & Plumbing has completed 93 jobs in Roberts, WI in the last 12 months. The first job there was in May 2018.
Performed comprehensive HVAC maintenance on 20-year-old system experiencing water leakage from secondary drain. Cleared plugged AC condensate drain line and addressed plugged secondary heat exchanger. Identified draft motor drawing maximum amperage, blower motor leaking oil, and improper drainage causing water discharge from auxiliary drain port. Recommended comfort advisor consultation due to multiple component issues requiring immediate attention including draft motor replacement, blower motor service, and heat exchanger evaluation.
Responded to warranty call on newly installed Daikin system experiencing repeated fuse failure and clicking sounds. Diagnosed issue as potential high voltage supply problem at the electrical service, consistent with previous equipment failures at this location. Recommended verification and correction of incoming power quality before proceeding with any equipment repairs to prevent damage to new HVAC system.
Responded to kitchen sink drain backup issue. Upon arrival, customer had already removed P-trap and attempted to clear blockage with 25-foot snake through pipe into toilet stack without success. Performed professional drain snaking of kitchen sink line to clear obstruction. Verified proper drainage flow and reinstalled plumbing components. Blockage successfully cleared and sink draining normally upon completion.
Completed annual plumbing inspection to diagnose ongoing water pressure issues throughout the residence. Upon inspection, identified well casing leak as primary cause of low pressure problem. Examined pressure tank system and associated plumbing connections, documenting corroded copper piping beneath sink fixtures and moisture damage on utility room floor near pressure tank base. Recommended well contractor service to pull pump and repair casing leak. Identified exterior faucet requiring replacement, scheduled for future service visit per homeowner request.
Responded to emergency water leak in ceiling caused by failed refrigerator water supply line. Located source of leak at connection point behind refrigerator, which had saturated ceiling and created water damage requiring restoration company notification. Shut off existing water supply, removed damaged refrigerator line, and installed new supply line from shutoff valve to refrigerator ice maker/water dispenser connection. Tested new installation for leaks, verified proper water flow, and confirmed ceiling leak had stopped. Coordinated with restoration company already on-site to address water damage mitigation.
Responded to no cooling complaint on 5-year-old Bryant Plus 90 furnace with Honeywell Bluetooth thermostat displaying flashing error. Measured only 8 volts at thermostat terminals instead of required 24 volts, indicating low voltage power supply issue. Located blown low voltage fuse at furnace control board and temporarily installed 3-amp resettable breaker to diagnose root cause. Detected burnt odor near control board area during inspection. Upon further diagnosis, observed blower relay rapidly cycling on and off, indicating failed control board causing excessive current draw that resulted in blown fuse. Control board determined to be defective and beyond repair. During comprehensive system inspection, discovered secondary heat exchanger showing signs of active leakage, which poses safety concern and indicates significant deterioration of furnace heat exchanger assembly. Given the combination of failed control board requiring replacement and compromised heat exchanger integrity on a
Completed comprehensive preventive maintenance tune-up on residential split system air conditioning unit, including outdoor condenser unit and indoor furnace with evaporator coil. Performed full system inspection per maintenance agreement protocol, checking refrigerant levels, electrical connections, capacitor operation, contactor condition, and airflow measurements. All components found operating within manufacturer specifications with no deficiencies noted.
Responded to no-cool call on 3-year-old Gibson system. Discovered family of mice nesting in condenser electrical compartment with low-voltage control wire chewed through. Repaired damaged wiring by splicing connection, removed rodent debris, and performed preventive maintenance including condenser coil cleaning. Verified all electrical components operating within manufacturer specifications, confirmed 19-degree temperature differential across evaporator coil, and checked air filter condition. System restored to proper cooling operation.
Responded to service call for broken shower handle. Upon inspection, determined the shower cartridge required replacement. Successfully removed the failed cartridge and installed customer-supplied replacement cartridge. Tested the shower valve control handle for proper operation, confirming smooth lever movement and appropriate water flow control. All fixtures restored to full working condition with no leaks detected.
Replaced defective A2L sensor on evaporator coil under parts and labor warranty. Upon arrival, accessed indoor unit and located failed sensor on evaporator coil assembly. Removed old A2L sensor and installed new sensor from stock inventory. Reconnected sensor wiring and secured all connections. Cycled system through complete operational sequence and verified proper blower motor speeds across all stages. Monitored system for error codes and confirmed no fault messages present. Verified evaporator coil operation and proper refrigerant flow through liquid line. System restored to normal operation with all safety sensors functioning correctly.
Responded to no cooling complaint on 25-year-old residential HVAC system. Upon inspection, discovered failed dual capacitor with severe corrosion, pitted contactor, condenser fan motor leaking oil, and cracked heat exchanger. Due to safety concerns with the compromised heat exchanger, tagged furnace as unsafe for operation. Replaced dual capacitor, contactor, and condenser fan motor to restore cooling functionality. Heat exchanger replacement required for safe heating operation.
Completed annual cooling maintenance tune-up on residential air conditioning system under Family Rewards membership agreement. Performed comprehensive inspection of outdoor condensing unit and indoor air handler, including cleaning of all components, verification of refrigerant levels using digital instrumentation at supply register, and confirmation of proper thermostat operation. All systems tested and found operating within normal parameters with no deficiencies noted.
Responded to toilet repair at location 12-5 where inspection revealed a cracked toilet flange. Removed the existing corroded and deteriorated closet collar, which exhibited significant rust damage and structural compromise. Installed a new closet collar to restore proper toilet mounting and ensure a secure, leak-free seal for the fixture.
Responded to no-cool condition on 13-year-old residential air conditioning system where indoor unit circulated air but outdoor condenser unit failed to operate, producing only humming/hissing sound. Upon inspection, diagnosed failed dual capacitor testing significantly out of manufacturer specifications and condenser fan motor with visible oil leakage indicating bearing failure. Successfully replaced both dual run capacitor and condenser fan motor, restoring full system operation.
Responded to return service call for 20-year-old central air conditioning system with no cooling. Previously replaced blown 3-amp fuse on initial visit with system operating normally at departure, but unit failed again shortly after. Upon return inspection, diagnosed shorted control wire running from indoor unit to outdoor condenser unit causing repeated 3-amp fuse failure. Verified short in existing 2-wire thermostat control circuit through continuity testing. Replaced blown fuse and confirmed electrical short persists in existing wire run. System requires licensed electrician to install new 2-wire control circuit to condenser before unit can be safely restored to operation.
Responded to no-cool complaint on 20-year-old central air conditioning system. Upon arrival, discovered tripped 3-amp low-voltage fuse at furnace. Performed comprehensive inspection of all low-voltage wiring connections and routine components on both indoor and outdoor units, finding all connections and components within manufacturer specifications. Replaced faulty fuse and attempted to replicate failure condition without success. Cycled system power and initiated multiple cooling calls to verify proper operation—unit performed normally through all test cycles. Advised homeowner of system's advanced age and condition; no further repairs or replacement estimates requested at this time. System operational and restored to service.
Responded to no cooling complaint on 7-year-old central air conditioning system. Upon arrival, learned that the low-voltage fuse had previously blown and was replaced by homeowner, temporarily restoring operation. Conducted thorough inspection of indoor unit, checking for potential short circuits or wire contact with ductwork—no issues found. Proceeded to outdoor condensing unit and tested contactor resistance, which measured within acceptable range. Visually inspected all visible wiring for damage or contact points with no abnormalities detected. During operational assessment, observed condenser fan motor rotating in reverse direction, indicating potential component failure. Performed capacitor diagnostics using multimeter and found dual-run capacitor had completely failed—fan side reading zero microfarads and compressor side significantly below rated specification. This capacitor failure explained both the reverse fan rotation and system's inability to cool properly. Replaced faile
Replaced defective evaporator coil under manufacturer warranty in residential HVAC system. Performed system evacuation, recharged refrigerant to proper specifications, and verified operational performance upon completion.
Returned to property to install gas shut-off valve in basement as previously sold. Installed new gas shut-off valve with red handle on main gas line, creating flared connection on top fitting to ensure proper seal. Upon completion, performed comprehensive leak testing on all connections using approved methods to verify system integrity. Successfully re-lit pilot lights for water heater and fireplace, confirming proper gas flow and safe operation of all appliances.
Responded to emergency gas leak at exterior fitting serving fireplace and pool heater. Upon arrival, utility company had shut off main gas meter to residence due to leak on unvalved line. Verified leak at flare fitting which was hand-tight with compromised flare connection. Attempted tightening but flare remained defective. Due to spatial constraints at original location, installed new section of gas-tight line routed through fence to allow proper connection access. Completed installation, pressurized system, and performed leak check verification on all connections. Restored gas service to residence and relit water heater pilot light and one fireplace pilot successfully. Second fireplace pilot would not light, which homeowner confirmed is a pre-existing intermittent issue with that unit. Verified pool heater operation and confirmed all gas appliances functioning properly with no active leaks detected.