Few communities in western Wisconsin combine as many different housing styles and homeowner needs as River Falls. The city continues to grow rapidly while maintaining its strong connection to UWRF, local agriculture, and the outdoor lifestyle that makes the Kinnickinnic River Valley such a desirable place to live. That means our technicians regularly work in everything from historic homes and student rentals to executive homes, townhomes, and rural properties throughout Pierce County.
Locals simply call it “The Kinni,” and while the Kinnickinnic River is one of River Falls’ most recognizable landmarks, it also contributes to humidity levels that can make homes uncomfortable during the summer. We regularly help homeowners throughout neighborhoods like South Fork, Whitetail Ridge, and areas near Glen Park solve issues involving humidity, airflow, and aging cooling systems that struggle to keep pace with Wisconsin’s hot and humid weather.
Heat pumps can be a great alternative to traditional air conditioners. Like an AC, they can be paired with a forced-air furnace or air handler. Heat pumps look a lot like traditional air conditioning units but they work a bit differently.
Like a traditional air conditioner, they use the refrigeration cycle to provide cool air in your home. However, these units can use the refrigeration cycle to provide heat as well. To simplify it, they basically run in reverse. The refrigeration cycle allows the heat pump or AC to absorb heat and move it from one area to another. On cooling mode, the unit absorbs the heat from inside your home and releases it outside. On heating mode, it finds heat in the ambient outdoor air and moves it inside to heat your home. While that might not seem like something that can work in our harsh, Wisconsin winters, heat pumps use technology that allow them to work in subzero temperatures.
On heating mode, heat pumps are more efficient than electric and gas-fired furnaces. This is because they don’t have to “create” heat but rather move it from one area to another. Many people who use heat pumps chose them for this reason. Higher energy efficiency means lower operating costs.
Important note for heat pump installations: if you plan to rely on your heat pump for home heating, you must choose a unit that is rated for low temperatures. There are many varieties of heat pumps. The ones that work great in Florida do not work well here. We can use heat pumps efficiently in Wisconsin but you have to have the right one!
Whether you’re dealing with uneven temperatures, rising energy bills, or an older AC system, our team can help improve comfort and efficiency throughout your home.
Why Landlords, Families, and Acreage Owners Need Different Heating SolutionsRiver Falls is one of the few markets where we might service a student rental near UWRF, a family home in Sterling Ponds, and a rural acreage outside town all in the same day. Each property has different heating demands, which is why there is no one-size-fits-all approach when it comes to furnaces, Boilers, Heat Pumps, and Geothermal Systems. Long Wisconsin winters make reliability and efficiency important for every homeowner, regardless of where they live.
Whether you’re maintaining a rental property, upgrading a family home, or improving efficiency on a rural property, we can help you find the right solution.
As River Falls continues to grow, more homeowners are paying attention to indoor air quality. Seasonal allergies, dust, dry winter air, summer humidity, and pet dander all affect comfort inside the home. We frequently help families throughout Highview Meadows, South Fork, and other growing neighborhoods improve indoor comfort through better filtration and humidity control.
The right air quality strategy can improve comfort throughout every season while helping your Heating and A/C system operate more efficiently.
River Falls continues to attract homeowners who are investing in electric vehicles, home offices, smart home technology, backup generators, and upgraded Heating and Air Conditioning systems. As a result, we are seeing strong demand for electrical improvements throughout both newer subdivisions and rural properties where reliability and backup power have become increasingly important.
Whether you’re upgrading a panel, preparing for an EV charger, or installing a generator, our team can help ensure your home’s electrical system is ready for future demands.
From historic homes near downtown to newer developments along County Road FF, plumbing systems throughout River Falls face challenges ranging from frozen pipes and leaking water heaters to hard water and sump pump concerns. We help homeowners protect their homes from costly water damage while improving reliability, efficiency, and water quality.
Whether you’re dealing with a plumbing emergency or planning a preventative upgrade, our team is ready to help.
River Falls is one of the most diverse service markets we work in. Few communities combine university housing, growing subdivisions, rural acreages, Twin Cities commuters, and long-established neighborhoods all within the same market. That variety keeps our technicians working throughout the area every day.
Hurlburt is proud to support the River Falls community through our partnership with UW–River Falls Athletics, including sponsorship of the new softball field. We believe in investing in the communities we serve and building long-term relationships with homeowners throughout the Kinnickinnic River Valley.
Whether you’re attending River Falls Days, Bacon Bash, River Dazzle, or cheering on the UWRF Falcons, you’ve likely seen a Hurlburt truck somewhere around town.
Logan P checked out my garbage disposal, found the Allen wrench, made an adjustment and it worked. He was knowledgeable, polite, and not in a hurry. He’s a fine technician and I’d get him again.
Both team members were great and friendly. They explained everything they were doing and kept me up to date. Doug was very good.
First time customer. Requested both furnace and AC be checked and cleaned. Trevor showed up on time, was quick even in the rain, and explained everything fully. Would definitely recommend Hurlburt and Trevor.
From charming homes near downtown to student rentals by UWRF, growing neighborhoods like Sterling Ponds and Whitetail Ridge, and rural properties beyond city limits, every River Falls home has its own needs. Each property comes with different systems, layouts, and challenges, and Hurlburt brings the experience and local insight to handle them all with confidence and care.
Responded to a water leak originating from the washing machine area. Upon investigation, discovered the air chamber hose connection had corroded and separated, causing the leak. Cut open the wall to access the failed connection, removed the corroded components, and installed a new air chamber hose connection with proper securing clamps and flexible hoses to restore proper function and prevent future leakage.
Responded to no cooling complaint on Lennox heat pump system displaying multiple error codes including E311/E312 (obstructed airflow), A800, and C100. Customer reported recent outdoor coil freeze-up condition that had since thawed. Upon arrival, performed comprehensive system inspection and found outdoor condenser coil heavily impacted with dirt and debris, significantly restricting heat transfer capability. Cleaned outdoor coil thoroughly to restore proper airflow and heat rejection. Initiated system startup and monitored operation under load. Initial refrigeration diagnostics revealed low suction pressure readings that initially suggested potential refrigerant undercharge; however, subcooling and superheat measurements were within manufacturer specifications, indicating adequate refrigerant charge. Proceeded with indoor unit inspection at air handler/furnace location. Discovered return air filter severely restricted with accumulated dirt and debris, causing significant airflow redu
Responded to service call for leaking well pressure tank and pressure gauge in basement utility area. Upon inspection, confirmed active leak at pressure gauge connection on 12-5 gallon well pressure tank. Replaced faulty pressure gauge with new unit, ensuring proper seal and thread connection. Discussed potential relocation options for pressure tank system with customer for future consideration.
Responded to service call for water leaking from furnace during AC operation. Diagnosed plugged condensate drain line elbow on evaporator coil caused by debris accumulation. Disassembled all condensate drain fittings, cleared debris blockage, reassembled system, and performed flow test with water to verify proper drainage function. System restored to normal operation.
Responded to no cooling complaint on 10-year-old Carrier air conditioning system. Upon arrival, confirmed unit was completely non-operational with no power to compressor or condenser fan. Diagnostic testing revealed failed dual run capacitor preventing system startup. Measured capacitance values and confirmed capacitor was out of specification and required replacement. Installed new dual run capacitor and restored power to unit. Verified contactor operation and confirmed proper engagement. Measured compressor and condenser fan motor amp draws, which were within manufacturer specifications. Checked refrigerant charge using temperature and pressure readings; values appeared slightly skewed due to excessive dehumidification load but determined charge was adequate. Inspected air filter and found it clean with no restrictions. Visually inspected evaporator coil and confirmed it was clean with no blockage affecting airflow. System successfully returned to normal cooling operation. Discusse
Performed comprehensive cooling system tune-up and inspection on 13-year-old Gibson air conditioning unit as part of recurring maintenance agreement. Conducted thorough evaluation of all major components including contactor, capacitor, refrigerant charge, condenser coil, amp draws, blower wheel, control board, and evaporator coil—all found to be in good working condition. Replaced dirty furnace filter and verified temperature drop at 18 degrees, confirming system is operating within manufacturer specifications with no deficiencies noted.
Responded to a pinhole leak in copper piping located in the utility room mechanical area. Upon inspection, identified a small leak in the copper line and observed widespread corrosion throughout the copper piping system and fittings, indicating advanced aging of the plumbing infrastructure. The existing system includes a water filtration unit with pressure regulation components, multiple copper supply lines, and various valve assemblies showing signs of oxidation and patina buildup. Performed immediate repair of the active pinhole leak to stop water intrusion and restore system integrity. Documented the extensive corrosion present on copper pipes and fittings throughout the mechanical room for follow-up evaluation. Recommended comprehensive assessment for potential re-piping of remaining copper lines due to the deteriorated condition of the existing plumbing system to prevent future failures.
Responded to no cooling complaint for gymnasium area at daycare facility. Found indoor fan motor operating but outdoor unit completely non-operational. Performed diagnostic testing on outdoor unit components and identified failed capacitor preventing compressor and condenser fan operation. Replaced defective capacitor with new unit, restored power, and verified proper system operation with adequate cooling performance. Recommended preventative maintenance service for all four rooftop units due to observed dirt accumulation affecting system efficiency.
Responded to no cooling call on R-22 system. Upon arrival, confirmed outdoor unit not operating. Verified thermostat was calling for cooling but contactor would not engage. Discovered low pressure switch was open, indicating loss of refrigerant charge. System found completely flat with no refrigerant present. Performed visual inspection of outdoor condenser unit and located significant oil accumulation on condenser coil, confirming active refrigerant leak at coil. Documented findings with photos showing coil condition and leak evidence. Advised customer that condenser coil replacement is required due to leak, or full system replacement should be considered given age of equipment and R-22 refrigerant type. Scheduled follow-up consultation to review repair versus replacement options.
Responded to no-cooling complaint on 15-year-old residential central air conditioning system. Upon inspection, discovered failed dual-run capacitor and rodent nest obstructing airflow within outdoor condensing unit. Replaced defective capacitor with proper OEM-specification component. Performed thorough cleanout of condenser coil and cabinet, removing all debris and nesting material. Washed condenser coil to restore proper heat transfer efficiency. Following mechanical repairs, performed refrigerant system diagnostics using manifold gauge set. Testing revealed system operating with insufficient refrigerant charge, indicating potential leak in refrigeration circuit. Given the age of the equipment and multiple compounding failures, provided comprehensive repair versus replacement options to customer. Due to cost-effectiveness considerations and system age exceeding typical service life expectancy, customer elected to schedule consultation with service advisor for full system replacement
Responded to call regarding intermittent sewer odor emanating from bathroom drain. Upon arrival, inspected plumbing fixtures and drainage system. No active sewer smell detected at time of inspection. Evaluated toilet installation and determined unit may require resetting to ensure proper seal at floor flange. Provided estimate for toilet reset service to address potential source of odor infiltration.
Responded to water leak complaint near furnace area. Upon inspection, identified multiple sources contributing to water accumulation: clogged air conditioner condensate drain line, sweating suction line causing condensation drip, and drain pipe displaced approximately one foot from floor drain opening. Cleared condensate drain obstruction and repositioned drain pipe to proper drainage location. Identified potential secondary leak in evaporator coil drain pan and noted water heater showing signs of leakage as separate issue. Performed complete system tune-up on HVAC equipment to ensure optimal operation. Documented conditions with photos showing supply duct temperatures, drain pan configuration, and floor water damage. Provided recommendations for water heater replacement and continued monitoring of coil drain pan condition.
Responded to no cooling complaint on 21-year-old Lennox system. Upon inspection, found system cycling improperly with condenser shutting off prematurely while indoor blower continued to run. Used Fieldpiece manifold gauge to diagnose refrigerant levels and confirmed system is significantly low on R410A refrigerant, indicating a leak in the system. Observed water accumulation on floor around indoor unit. System requires leak detection, repair, and refrigerant recharge. Provided customer with repair estimate for R410A system work and recommended comfort advisor consultation given age of equipment.
Responded to no cooling complaint on approximately 5-year-old Goodman air conditioning system. Upon inspection, discovered disconnect box receiving only 120V instead of required 240V, preventing system operation. Identified faulty disconnect box as root cause requiring electrical repair. Customer declined service as family member who is a licensed electrician will replace the disconnect box.
Performed comprehensive tune-up on 20-year-old residential air conditioning system. System was found to be low on refrigerant, which was replenished to manufacturer specifications. Given the age and condition of the equipment, customer was advised that the system is nearing end of service life and an estimate for replacement will be provided.
Successfully installed a Toto Drake comfort height toilet at the customer's residence. The new fixture was properly secured to the flange, all connections were sealed and tested for leaks, and the unit was verified to be functioning correctly upon completion.
Performed comprehensive tune-up on a 22-year-old Carrier air conditioning system. Inspected indoor air handler, confirming clean air filter, balanced airflow, and proper supply/return temperature split. Verified condensate drain line operating correctly with no blockages. Evaluated outdoor condensing unit, testing refrigerant pressures and temperatures which were within manufacturer specifications. Measured capacitor, contactor, and compressor amperage draw, confirming all electrical and mechanical components functioning within normal operating parameters. Cleaned outdoor coil to maintain optimal heat transfer efficiency. System currently operating in normal working condition with no deficiencies noted.
Completed annual AC tune-up and inspection on residential cooling system. Unit operating properly with supply air temperature measuring 53.9°F, electrical connections secure and within specifications, and condenser coils clean with adequate airflow through outdoor unit.
Completed Family Rewards cooling maintenance visit on residential air conditioning system. Performed comprehensive AC tune-up inspection and identified weak capacitor on compressor side. Replaced defective capacitor to restore proper system operation and ensure reliable cooling performance.
Performed comprehensive AC maintenance tune-up on an 11-year-old system serving the lower level of the residence. During inspection, identified a weak dual capacitor and determined the system was low on R410A refrigerant, indicating a potential leak in the refrigerant circuit. Documented equipment condition with photos of both the outdoor condensing unit's electrical components and the indoor air handler assembly, and provided recommendations for repair or replacement options to address the failing capacitor and refrigerant loss issues.