Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Few communities in western Wisconsin combine as many different housing styles and homeowner needs as River Falls. The city continues to grow rapidly while maintaining its strong connection to UWRF, local agriculture, and the outdoor lifestyle that makes the Kinnickinnic River Valley such a desirable place to live. That means our technicians regularly work in everything from historic homes and student rentals to executive homes, townhomes, and rural properties throughout Pierce County.
Locals simply call it “The Kinni,” and while the Kinnickinnic River is one of River Falls’ most recognizable landmarks, it also contributes to humidity levels that can make homes uncomfortable during the summer. We regularly help homeowners throughout neighborhoods like South Fork, Whitetail Ridge, and areas near Glen Park solve issues involving humidity, airflow, and aging cooling systems that struggle to keep pace with Wisconsin’s hot and humid weather.
Heat pumps can be a great alternative to traditional air conditioners. Like an AC, they can be paired with a forced-air furnace or air handler. Heat pumps look a lot like traditional air conditioning units but they work a bit differently.
Like a traditional air conditioner, they use the refrigeration cycle to provide cool air in your home. However, these units can use the refrigeration cycle to provide heat as well. To simplify it, they basically run in reverse. The refrigeration cycle allows the heat pump or AC to absorb heat and move it from one area to another. On cooling mode, the unit absorbs the heat from inside your home and releases it outside. On heating mode, it finds heat in the ambient outdoor air and moves it inside to heat your home. While that might not seem like something that can work in our harsh, Wisconsin winters, heat pumps use technology that allow them to work in subzero temperatures.
On heating mode, heat pumps are more efficient than electric and gas-fired furnaces. This is because they don’t have to “create” heat but rather move it from one area to another. Many people who use heat pumps chose them for this reason. Higher energy efficiency means lower operating costs.
Important note for heat pump installations: if you plan to rely on your heat pump for home heating, you must choose a unit that is rated for low temperatures. There are many varieties of heat pumps. The ones that work great in Florida do not work well here. We can use heat pumps efficiently in Wisconsin but you have to have the right one!
Whether you’re dealing with uneven temperatures, rising energy bills, or an older AC system, our team can help improve comfort and efficiency throughout your home.
Why Landlords, Families, and Acreage Owners Need Different Heating SolutionsRiver Falls is one of the few markets where we might service a student rental near UWRF, a family home in Sterling Ponds, and a rural acreage outside town all in the same day. Each property has different heating demands, which is why there is no one-size-fits-all approach when it comes to furnaces, Boilers, Heat Pumps, and Geothermal Systems. Long Wisconsin winters make reliability and efficiency important for every homeowner, regardless of where they live.
Whether you’re maintaining a rental property, upgrading a family home, or improving efficiency on a rural property, we can help you find the right solution.
As River Falls continues to grow, more homeowners are paying attention to indoor air quality. Seasonal allergies, dust, dry winter air, summer humidity, and pet dander all affect comfort inside the home. We frequently help families throughout Highview Meadows, South Fork, and other growing neighborhoods improve indoor comfort through better filtration and humidity control.
The right air quality strategy can improve comfort throughout every season while helping your Heating and A/C system operate more efficiently.
River Falls continues to attract homeowners who are investing in electric vehicles, home offices, smart home technology, backup generators, and upgraded Heating and Air Conditioning systems. As a result, we are seeing strong demand for electrical improvements throughout both newer subdivisions and rural properties where reliability and backup power have become increasingly important.
Whether you’re upgrading a panel, preparing for an EV charger, or installing a generator, our team can help ensure your home’s electrical system is ready for future demands.
From historic homes near downtown to newer developments along County Road FF, plumbing systems throughout River Falls face challenges ranging from frozen pipes and leaking water heaters to hard water and sump pump concerns. We help homeowners protect their homes from costly water damage while improving reliability, efficiency, and water quality.
Whether you’re dealing with a plumbing emergency or planning a preventative upgrade, our team is ready to help.
River Falls is one of the most diverse service markets we work in. Few communities combine university housing, growing subdivisions, rural acreages, Twin Cities commuters, and long-established neighborhoods all within the same market. That variety keeps our technicians working throughout the area every day.
Hurlburt is proud to support the River Falls community through our partnership with UW–River Falls Athletics, including sponsorship of the new softball field. We believe in investing in the communities we serve and building long-term relationships with homeowners throughout the Kinnickinnic River Valley.
Whether you’re attending River Falls Days, Bacon Bash, River Dazzle, or cheering on the UWRF Falcons, you’ve likely seen a Hurlburt truck somewhere around town.
Logan P checked out my garbage disposal, found the Allen wrench, made an adjustment and it worked. He was knowledgeable, polite, and not in a hurry. He’s a fine technician and I’d get him again.
Both team members were great and friendly. They explained everything they were doing and kept me up to date. Doug was very good.
First time customer. Requested both furnace and AC be checked and cleaned. Trevor showed up on time, was quick even in the rain, and explained everything fully. Would definitely recommend Hurlburt and Trevor.
From charming homes near downtown to student rentals by UWRF, growing neighborhoods like Sterling Ponds and Whitetail Ridge, and rural properties beyond city limits, every River Falls home has its own needs. Each property comes with different systems, layouts, and challenges, and Hurlburt brings the experience and local insight to handle them all with confidence and care.
Responded to no-cooling complaint on 2005 Bryant PLUS 90 system with evaporator coil freeze-up. Upon arrival, found outdoor condenser coils clean and evaporator coil free of debris with clear condensate drain. Connected manifold gauges and observed refrigerant charge slightly below optimal range for R-22 system but within marginal operating parameters. Customer had recently installed MERV 11 air filter, which was determined to be excessively restrictive for this system's blower capacity, resulting in reduced airflow across evaporator coil and subsequent ice formation. After filter had been in place approximately 24 hours, coil began normal condensation cycle and ice buildup ceased. Verified airflow restoration and monitored system operation until cooling function returned to normal. Advised customer that R-22 refrigerant is no longer serviced and system replacement should be considered due to age and refrigerant phase-out, though current operation is functional for continued use.
Completed phone follow-up with customer regarding questions about reverse osmosis system installation work. Technician will return contact upon availability to address specific concerns and provide technical clarification on the completed installation.
Responded to no-cool call on recently installed air conditioning system. Upon inspection, discovered low voltage control wiring had been severed near landscaping, likely damaged during bush trimming. The control wire routing extended from the window around the exterior of the home, under the deck, and past shrubbery in a suboptimal configuration. Repaired the damaged wire by splicing at the break point, restored power to the system, and confirmed proper operation of the air conditioning unit.
Responded to no cooling complaint on 10+ year old air conditioning system with system malfunction error displayed on thermostat. Diagnostic testing revealed failed condenser fan motor, defective run capacitor, and compressor exhibiting abnormal operational sounds indicating potential failure. Replaced condenser fan motor and run capacitor to restore system operation, though compressor condition warrants monitoring for future replacement needs.
Responded to a no cooling call on a twelve-year-old air conditioning system. Upon inspection, found clogged air filters at the indoor unit. Examined the outdoor condenser and discovered severe coil damage caused by animal urine, heavy pollen accumulation, and missing fin sections. System testing revealed complete refrigerant loss with an audible leak detected at the damaged coil area. Due to the extent of condenser coil damage and system age, scheduled a comfort advisor to discuss replacement options with the homeowner.
Responded to a continuously running toilet in unit 8-12. Upon inspection, identified a malfunctioning fill valve that was stuck in the open position, causing constant water flow into the tank. Replaced the defective fill valve with a new unit, restoring proper operation and stopping the continuous running condition.
Installed new ADA-compliant comfort height toilet in residential bathroom, replacing existing fixture. Installation included new wax ring seal and mounting bolts to ensure proper connection to the waste flange. Completed basic installation with toilet properly secured and positioned against wall in corner location, verified proper function and seal integrity.
Responded to no cooling complaint on an approximately 8-year-old Bryant air conditioning system. Upon inspection, diagnosed a failed capacitor on the outdoor condensing unit. Replaced the defective capacitor with new component, performed operational test run to verify proper system function, and checked refrigerant charge levels which were found to be within manufacturer specifications. System restored to full cooling operation.
Responded to no cooling complaint on York system. Diagnosed failed ECM condenser fan motor module preventing outdoor unit fan operation. Module mounted separately from motor and determined to be intermittently failing. Provided warranty and non-warranty pricing options for ECM module replacement pending manufacturer warranty verification.
Completed comprehensive air conditioning tune-up and maintenance inspection on residential HVAC system. Tested system operation and confirmed proper cooling performance with satisfactory temperature drop at basement supply. Verified air filter condition (clean), inspected blower assembly, and confirmed condensate drain line flowing freely. Performed condenser coil cleaning at outdoor unit, which had accumulated leaves and organic debris around internal components. Inspected all electrical connections, refrigerant lines, and mechanical components. System operating within normal parameters with no deficiencies noted.
Responded to no cooling complaint on 15-year-old system. Upon arrival, confirmed system was running but providing minimal temperature drop. Connected manifold gauges to outdoor unit and found critically low refrigerant pressure of 1 PSI on suction line with standing pressure of 30 PSI in R-410A system, indicating significant refrigerant leak. Advised customer of leak repair options and recommended obtaining quotes for complete system replacement given age of equipment before proceeding with repairs.
Responded to no cooling complaint with system completely inoperative. Found tripped low-voltage fuse at air handler. Upon inspection, discovered damaged thermostat wire at outdoor unit with exposed conductors causing short circuit, consistent with animal damage. Repaired compromised wiring and replaced low-voltage fuse. Performed complete condenser coil cleaning due to heavy dirt accumulation affecting system performance. Cycled system through heating and cooling modes, verified proper operation with no further fuse trips. Unit restored to normal cooling operation.
Responded to service call for multiple faucet issues including two leaking Delta bathroom faucets and reduced hot water flow in kitchen faucet. Replaced hot and cold cartridges in both lavatory faucets to resolve leaking issues. Kitchen faucet diagnosed with clogged aerator or filter restricting hot water flow on that side only.
Responded to a plumbing repair involving garbage disposal installation issues and exterior hose bib failure. Upon arrival, found that existing kitchen sink drain piping was incompatible with garbage disposal unit following recent countertop and sink replacement. Old PVC drain lines were permanently glued and required complete reconfiguration. Demolished and removed existing drain assembly, then installed new PVC drainage system with proper fittings and trap configuration to accommodate garbage disposal unit. Ensured proper venting and slope for adequate drainage. Additionally, addressed malfunctioning outdoor hose bib that would not shut off water flow. Diagnosed failed valve mechanism requiring full replacement. Removed deteriorated hose bib assembly from exterior wall and installed new frost-free hose bib with proper sealing and mounting. Tested both kitchen drainage system and exterior faucet for leaks under operating pressure. Verified garbage disposal operation with water flow an
Installed a Standard brand tub spout with diverter to enable proper shower operation. The new fixture was secured to the existing wall connection, replacing a failing component and restoring full functionality to the bathtub and shower system.
Responded to service call for air conditioning system not operating properly. Diagnosed failed 35/5 dual run capacitor on outdoor condenser unit. De-energized system and safely discharged old capacitor before removal. Installed new 35/5 capacitor with proper electrical connections to compressor and condenser fan motor. Restored power to unit and verified proper startup sequence with compressor and fan motor engaging correctly. System tested and confirmed cooling operation restored to normal parameters.
Completed comprehensive AC tune-up service on a 3-year-old residential air conditioning system. Performed thorough cleaning of outdoor condenser coil to ensure optimal heat transfer and system efficiency. Inspected air filter at indoor unit and confirmed clean condition requiring no replacement. Conducted complete electrical cabinet inspection including amperage measurements and connection verification, with all readings within normal operating parameters. System tested and confirmed operating properly with no deficiencies or concerns identified.
Responded to water line damage caused during construction remodeling work. Located pinhole leak in copper supply line that had been struck during the renovation. Removed damaged section of copper piping and installed new copper pipe to restore water line integrity. Tested system for proper pressure and verified no additional leaks present.
Completed routine cooling maintenance on a 1999 Lennox condenser unit as part of a membership agreement. Performed comprehensive system evaluation including compressor amp draw testing, which revealed run amps on the high end indicating potential efficiency concerns. Verified capacitor readings within acceptable range and confirmed refrigerant charge at proper levels. Discovered and removed mouse nest from unit that posed electrical hazard risk. Replaced dirty air filter and measured temperature splits across the system. All measurements confirmed adequate cooling performance despite the age of the equipment. System operational but running below optimal efficiency due to elevated amperage readings and age-related wear. Final verification confirmed proper cooling function with acceptable airflow and temperature differential.
Completed preventive maintenance on 2-year-old heat pump system including condenser coil rinse and full system inspection. Unit operating within manufacturer specifications with all components functioning properly. Maintenance agreement service fulfilled per scheduled 8-12 AC tune-up protocol.