To get assistance with your HVAC and plumbing repairs, maintenance, and installations, look no further! To see what our satisfied customers think about our HVAC and plumber services in Prescott, WI, read our reviews below.
Hurlburt Heating & Plumbing has completed 20 jobs in Prescott, WI between May 2026 and June 2026.
The most recent job was on June 22, 2026.
Hurlburt Heating & Plumbing has completed 121 jobs in Prescott, WI in the last 12 months. The first job there was in July 2017.
Responded to no cooling complaint on 9-year-old residential air conditioning system experiencing evaporator coil freeze-up after 20 minutes of operation. Upon arrival, confirmed system was low on refrigerant and verified outdoor condenser coil was clean with adequate airflow. Performed electrical diagnostics using multimeter to test system components and verify proper voltage. Documented outdoor unit condition and internal electrical measurements. System requires refrigerant charge and leak detection to restore proper cooling operation; presented repair options to address refrigerant loss and restore system functionality.
Responded to service call for continuously running toilet in unit 12-4. Upon inspection, found flush tower mechanism experiencing operational failure due to excessive iron content in water supply causing mineral buildup and interference. Tank interior exhibited significant rust-colored staining and discoloration throughout, with brownish water present indicating high iron concentration. Flush valve assembly components showing signs of binding and improper operation from accumulated mineral deposits. Diagnosed that internal flush mechanism requires complete replacement due to deterioration from poor water quality conditions. Provided estimate for replacement of all internal tank components to restore proper toilet function and eliminate continuous running condition.
Responded to leak complaint on previously installed Jumbo Valve-in-head water filter housing system. Upon inspection, identified improper seal on filter canister causing water leakage. Removed and reinstalled filter housing unit, ensuring proper threading and O-ring seal between blue head assembly and white filter canister. Verified system operation through bypass, off, and filtration modes, confirming no active leaks and proper functionality upon completion.
Responded to emergency plumbing call for active pipe leak behind shower wall causing water damage to basement below. Main water supply was shut off upon arrival to prevent further damage. Diagnosed hot water control issue at bathtub faucet where hot water valve failed to shut off completely. Accessed plumbing behind shower wall and replaced defective valve seat and washer assembly. Installed new ball valves on both hot and cold water supply lines feeding the shower to provide improved shutoff capability and facilitate future maintenance access. Tested all fixtures for proper operation and verified leak was resolved with no active water flow detected behind wall or into basement area.
Responded to no hot water call and diagnosed 50-gallon natural gas water heater from 2011 experiencing gas lockout condition and failure to ignite. After confirming unit was non-operational and beyond economical repair, removed and replaced the existing water heater with new unit, reconnected all water supply lines, gas piping, and venting systems per manufacturer specifications and local code requirements.
Responded to service call for water softener system experiencing hammering noise during regeneration cycle. Upon diagnosis, determined the pump serving the water softener and HVAC system required replacement due to faulty check valve system causing water hammer. Successfully installed new pump to restore proper operation of water treatment system and eliminate noise issue.
Responded to no cool complaint on 8-year-old system. Upon arrival, verified main floor thermostat holding at 69°F while basement thermostat read 65°F in off position. Conducted thorough inspection of return air system throughout residence. Found inadequate return air flow with disproportionate return vent distribution—large returns located in basement with minimal returns on main living levels. Tested and confirmed dampers operational. Diagnosed probable return air imbalance causing conditioned air to short-cycle through basement rather than properly circulating through main living areas. Documented findings with photos of basement ductwork, copper refrigerant lines, and thermostat display. Advised customer of return air distribution issue affecting system performance and cooling efficiency on upper levels.
Completed annual air conditioning tune-up on one-year-old system. Performed comprehensive maintenance including inspection of condenser unit, verification of proper refrigerant levels, and filter assessment. System found to be clean and operating within normal parameters with no deficiencies noted.
Responded to basement toilet leaking issue and inspected tank mechanism to diagnose problem. Removed tank lid to assess internal components including fill valve assembly and float ball system. Provided estimates for wax ring replacement and new toilet installation options.
Completed comprehensive cooling season maintenance on 4-year-old Lennox HVAC system. Performed full AC tune-up including removal of condenser panels and thorough rinsing of condenser coil to ensure optimal heat transfer. Replaced air filter and humidifier pad to prepare system for upcoming winter season. Verified evaporator drain line was flowing properly with no blockages. Started system and confirmed all components operating within normal parameters with no issues detected.
Completed first-call AC maintenance tune-up on 25-year-old R22 system. Identified failing contactor and dual capacitor requiring replacement, system low on refrigerant with evidence of previous stop leak use. Documented equipment make, model, and serial numbers with photographs, and recommended comfort advisor consultation due to age of system and multiple component failures.
Completed comprehensive plumbing inspection of residential property, including examination of basement utility area with PEX manifold distribution system and newly renovated bathroom with updated shower fixtures and tile work. All plumbing systems, connections, and fixtures were visually inspected and found to be in proper working order with no leaks or deficiencies noted at time of inspection.
Responded to no hot water complaint on 10-12 year old electric water heater. Diagnosed failed lower heating element causing complete loss of hot water production. Due to age of unit and extent of failure, recommended and completed full water heater replacement. Removed existing electric water heater and installed new unit with proper electrical connections to existing panel. Verified all copper supply line connections, tested unit operation, and confirmed hot water delivery restored to residence.
Completed comprehensive plumbing inspection of residential property, examining all accessible fixtures and systems. Inspected bathroom sink with dual-handle faucet assembly, drain stopper mechanism, and surrounding plumbing connections, confirming proper operation and no visible leaks. Documented electrical panel and exposed plumbing infrastructure in unfinished area for reference.
Responded to a leaking exterior hose bibb that was losing approximately one gallon of water per day, requiring the homeowner to shut off water nightly to prevent excessive water waste. Upon inspection, confirmed the hose bibb was actively leaking and could not maintain a proper seal. Removed the failed hose bibb and installed a new replacement unit, restoring proper function and eliminating the water loss.
Completed comprehensive HVAC maintenance agreement including furnace and air conditioning system tune-up. Performed furnace operational testing, verified gas pressure settings within specifications, and confirmed temperature rise within acceptable range. Cleaned flame sensor, tested hot surface igniter functionality, and inspected air filter condition. Examined blower compartment and verified proper operation of all components. Switched to cooling mode and measured temperature drop across evaporator coil. Cleared condensate drain lines on both indoor and outdoor units. Performed exterior condenser coil cleaning to remove accumulated debris and ensure optimal heat transfer. Inspected electrical connections, wiring, and components at outdoor unit. All systems tested and operating within manufacturer specifications with no deficiencies noted.
Performed comprehensive operational inspection of natural gas tanked water heater and water softener system in residential basement utility area. Verified proper function of all water heater components including burner assembly, venting system, temperature controls, and pressure relief valve. Checked water softener operation and confirmed adequate system performance. Provided detailed estimate for replacement of existing unit with 50-gallon standard vent natural gas water heater, including specifications for proper venting requirements and installation parameters. Documented existing equipment configuration with copper supply lines, control panel functionality, and current installation setup. All systems found operational at time of inspection.
Completed installation of a 50-gallon power vent water heater in the utility room. Connected all copper supply lines with proper fittings and valves, installed power vent exhaust system with PVC piping, and secured unit to manufacturer specifications. All plumbing connections were tested and verified leak-free, electrical connections completed, and system is fully operational.
Responded to no heat call on furnace over 10 years old with flashing ignition failure code on control board. Diagnosed failed gas valve preventing fuel delivery to burner assembly despite pilot ignition attempts. Replaced defective gas valve and restored heating operation. Comfort advisor consulted regarding system age and long-term options.
Responded to service call for whistling toilet and dishwasher drainage issues. Completed full replacement of two existing toilets with new Toto comfort height elongated ADA-compliant models. Removed old fixtures, installed new toilets with proper sealing and water supply connections, and tested both units for proper operation and leak-free performance.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.