Responded to service call for water softener leak. Discovered leak at bypass valve on main floor softener unit. Removed the leaking water softener and looped the existing 3/4" PEX lines together to maintain system functionality. Note: property was originally a duplex with dual softener systems; second softener remains in place and operational.
Performed semi-annual agreement maintenance service on furnace of indeterminate age. Completed comprehensive inspection including heat exchanger (camera inspection), venting, exhaust flue, burners, blower, inducer, all safety switches, flame sensor, igniter, and gas pressures. Noted rust damage inside furnace cabinet caused by condensate drainage issues from evaporator coil. System currently operating normally.
Responded to emergency service call for a pin hole leak on a copper elbow fitting connected to customer's water softener in the basement. Successfully repaired the compromised joint and also completed installation of a new kitchen faucet as requested. Utilized protective tarping during repair to prevent water damage to surrounding areas.
Responded to alert code 31 on thermostat for heat system with communication failure. Replaced thermostat which resolved initial code issue, however discovered no power to outdoor heat pump. Located tripped breaker that would not reset even after disconnecting heat pump. Determined electrical issue beyond HVAC scope; customer advised to schedule electrician to inspect circuit/breaker.
Performed scheduled furnace preventive maintenance, responding to intermittent startup issues. Inspected and tested all system components, including LP gas nozzle that was suspected of requiring cleaning. Evaluation of ductwork and combustion components showed normal operation with no malfunctions detected. System is currently operating within specifications.
Responded to a service call regarding a toilet leak. Upon inspection, found the toilet had been shut off due to leakage issues. Removed the existing toilet, replaced the wax ring seal, and reinstalled the unit properly. Tested for proper operation and verified no leaks were present after repair.
Diagnosed American brand natural gas water heater with no hot water issue; confirmed customer's suspicion of faulty thermocouple and identified failed pilot assembly as root cause. Provided customer with replacement options and estimates for new water heater installation.
Responded to no-heat call for 20-year-old furnace. Diagnostic testing revealed furnace would ignite but blower motor was seized and unresponsive when receiving power from control board. Customer declined immediate repair as they want to consult with previous company who replaced blower motor approximately 4 years ago.
Completed routine maintenance on 4-year-old Lennox furnace with heat pump system. Inspected gas valve assembly, control components, wiring connections, and ventilation ducts. All components functioning properly; recommended continuing regular maintenance schedule.
Responded to a no-heat call for a 25-year-old Lennox G50 LP furnace. Diagnosed plugged burners and significant rust on the heat exchanger, particularly around eyelets. Critical issue identified: large hole in ventilation system that requires immediate replacement. Documented issues with photographs including corrosion damage. Service advisor scheduled to provide estimate for replacement furnace.
Diagnosed no cooling issue on a 2-year-old system. Found disconnected low voltage wiring at the control board with no Y and C connection. Removed aftermarket C-wire adapter module that was causing communication failure, then rewired the system with direct connections from original wires to a Honeywell T4 thermostat instead of the Nest. System now functioning properly with both cooling and heating operations confirmed.
Responded to service call for a 6-year-old 50-gallon electric water heater providing only five minutes of hot water. Diagnostic testing revealed failed bottom heating element as the root cause. Replaced bottom element to restore proper functionality, with the repair covered under manufacturer's warranty which expires November 30.
Completed a water heater installation at a customer's home. The job involved removing the old water heater, installing a new one, and ensuring that the system was properly connected to the gas line. I also tested the water heater to ensure it was working correctly before leaving the home. The customer was pleased with the installation.
Air Conditioning System Repairs: After diagnosing frequent system shutdowns, we determined that the AC system was experiencing electrical component failure, particularly in the capacitor. We promptly replaced the faulty capacitor and performed comprehensive electrical system testing, ensuring reliable operation and preventing future breakdowns for the client's peace of mind.