We’ve assisted homeowners for over 65 years and will proudly service your home as well.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Plymouth typically experiences winter temperatures between 15 and 25 degrees Fahrenheit. So, if you wake up to discover your heater has died, you’ll need it repaired immediately. Fortunately, our furnace experts have the expertise you need. Enjoy small-town charm and reasonable prices when you reach out to us.
We Offer a Wide Range of Heating Services for Your Home, Including:
- Heating Repairs: Having your heater suddenly stop working is very inconvenient. Even a small issue can become a major problem if you don’t take action fast. Let our team of professionals correct the problem.
- Heating Installation: Are you looking for a new heater? Whether it’s the middle of the winter or summertime, we can help! Head to Emagine Willow Creek to catch a movie as we install your brand-new heater.
- Heating Maintenance: When was the last time you had preventative heating maintenance? Believe it or not, this is the best way to reduce your overall repair expenses. Plus, when you join the Hurlburt Family Rewards Club, you’ll get a discount on our services.
The temperature in Plymouth hovers around 80 degrees during the summer months, along with moderate to high humidity. Therefore, it’s always an issue when an AC stops working. Rather than dealing with your uncomfortable home, why not call us for expert cooling services and then go to Mulligan’s Indoor Golf? We’ll return cool air to your home as you enjoy yourself.
You Can Trust Our Lineup of Helpful Cooling Services for Your Home:
- Cooling Repairs: Is your AC blowing warm air or making excessive noise? Let our professional cooling experts take care of the problem. We’ll make sure your home cools off properly before we leave.
- Cooling Installation: Sometimes, it’s more cost-effective to install a new AC than to repair your old one. We’ll recommend the right-sized AC for your living environment. Go puzzle out an escape room at Breakout Games while we install your brand-new AC.
- Cooling Maintenance: Scheduling regular preventative maintenance will help you avoid major unexpected repairs. It’ll also keep your energy costs in line plus make your home comfortable. Ask about our Hurlburt Family Rewards Club to save even more.
Taking care of your plumbing is the best way to avoid a flooded house. Therefore, whether you have a tiny leak or a bigger problem, call us right away. Our professional plumbers will assist you by ensuring your plumbing works properly again. Steer clear of the many issues associated with a flooded home, including mold.
We have trained electricians on staff to help make sure your home gets wired correctly. After all, issues such as buzzing or dimming could eventually lead to a fire. Therefore, take control of your electricity by having us check it out. Any problems are immediately addressed for your peace of mind.
We’re Your Go-to Company When You Need Electrical Services:
- Electrical Repairs: Are you experiencing a burning smell or loose outlets? Both of these indicate that something is wrong with your electricity. We’ll fix it for you right away to provide peace of mind.
- Electrical Installation: Our electricians install new lighting fixtures, ceiling fans, and EV chargers. Plus, we take care of whole-home generators, circuit breakers, and carbon monoxide detectors. Our experts will make your home a more friendly, usable environment.
Plymouth is one of the largest cities in Minnesota. The good news is this means you can always find something to do. For example, if we’re repairing your plumbing, you can take a nature walk at Clifton E. French Regional Park. Or, if we’re installing a new AC, you can go enjoy craft beer
at Luce Line Brewing. Prefer to do something educational? Check out the Plymouth Historical Museum while we take care of your heater.
Choose Hurlburt whenever you need electrical, plumbing, heating and cooling services. Our team of more than 60 professionals includes professional plumbers and electricians. We also have 65+ years of industry experience, and all installations include a 12-month warranty. We provide high-quality work, and we always put people first.
Are you looking for an electrical, plumbing, or HVAC company in Plymouth? Reach out to our team of experts today!
Completed preventive maintenance agreement service on commercial HVAC system consisting of two rooftop units. Accessed rooftop equipment via building maintenance stairway. Replaced return air filters on both RTUs with 20x25x2 filters. Cleaned condenser coils on both rooftop units and performed thorough cleaning of pre-filters and condensate drain traps. Verified fan operation and cooling functionality on all equipment. All systems tested and operating within normal parameters upon completion of maintenance tasks.
Completed comprehensive 8-12 point tune-up on residential air conditioning and furnace system for preventive maintenance agreement member. Documented equipment makes, models, and serial numbers with detailed photographs of all HVAC components including furnace unit, air handler, and associated ductwork. During inspection, identified refrigerant charge slightly below optimal levels on AC system; noted system may require refrigerant addition or potential replacement consideration for future service planning.
Responded to no cooling call on 6-year-old AC system. Diagnosed failed capacitor as root cause of system malfunction. Replaced defective capacitor under warranty, restoring proper system operation and cooling functionality.
Responded to no-cool complaint on 6-year-old system for second opinion after another company reported rodent damage and low refrigerant. Upon arrival, thermostat was at setpoint of 72°F. Performed comprehensive system evaluation including air filter inspection, blower motor operation, outdoor unit coil condition, capacitor, contactor, and refrigerant charge verification. Located wire damage from rodent activity at outdoor unit; confirmed damage was limited to protective sleeve only with conductors intact. Secured exposed wiring with electrical tape. Measured supply/return air temperature delta at 19°F, confirming proper system performance. All components operating within normal parameters with no refrigerant loss detected. Explained that previous temperature issues likely resulted from extreme outdoor conditions (90°F+), heat gain from kitchen activities, and inadequate ductwork coverage to home addition near thermostat location rather than equipment malfunction. System operating prope
Responded to a toilet backup affecting only the fixture, with no impact to other drains in the residence. Upon arrival, removed the toilet to access the drain line and identified a toilet paper blockage located near the fixture connection. Utilized drain cable equipment to clear the obstruction, making multiple passes to ensure complete removal of the blockage. Verified proper drainage and line clearance using camera inspection equipment. Reinstalled the toilet with new wax ring seal, secured mounting bolts, and tested for proper flushing operation and water flow. Confirmed no leaks present at base or supply connections and verified system functioning normally upon completion.
Installed new brushed stainless steel kitchen faucet with high arched spout at single-family residence. Connected faucet supply lines to existing shutoff valves and verified proper water flow and drainage through double-basin stainless steel sink. Cleared basement toilet obstruction using closet auger, restoring proper flush function and drainage.
Responded to gas leak emergency at residential property where gas supply had been shut off for safety. Located and identified leak at underground fitting near fence line that connected two gas lines. Presented options to either cap the leaking line or replace the entire gas line run, with sales team scheduled to provide quote for new gas line installation from meter along house to deck grill location.
Completed annual cooling maintenance on 9-year-old air conditioning system. Replaced failing capacitor, outdoor temperature sensor batteries, and malfunctioning main level zone thermostat that was causing continuous fan operation when system was off. Verified all other components operating within specifications with proper refrigerant levels and system confirmed operational upon completion.
Responded to callback for excessive indoor humidity levels reading at 73%. Adjusted system airflow from 1200 CFM to 1050 CFM and disabled dehumidification mode on Lennox thermostat to optimize system performance. Upon adjustment, indoor humidity decreased to 69% with system cooling to setpoint of 70°F.
Responded to callback for air conditioning system not cooling. Upon arrival, found furnace control board not powered and 24V fuse open. Reset fuse and cycled system to restore operation. Performed comprehensive system check including thermostat wiring, control board connections, condenser operation, and capacitor testing—all components functioning within normal parameters. Addressed thermostat programming concerns by removing batteries, verifying C wire connection, and instructing occupants on proper use of Hold function to override scheduling feature. System restored to normal cooling operation.
Responded to no cooling complaint on residential split system air conditioning unit. Upon arrival, verified thermostat was calling for cooling at 75 degrees setpoint. Inspected air filter and blower speeds, both found satisfactory. Observed outdoor unit contactor not receiving 24V control voltage from thermostat, though 240V line voltage was present. Tested capacitor, found within specifications. Discovered outdoor coil heavily blocked with cottonwood debris, restricting airflow. Cleaned condenser coil thoroughly, restoring proper airflow. Replaced thermostat batteries and verified wire connections secure. During further inspection, found blower operating at lowest speed setting and reset button on furnace door switch tripped. Reset safety switch, restoring unit operation. Cycled power to system by disconnecting and reconnecting wiring to confirm proper startup. Checked refrigerant charge and found system operating below optimal levels. Measured supply and return air temperature diffe
Responded to warranty no-cool call on recently installed system that was not maintaining temperature. Upon inspection, discovered incorrect dip switch configuration on the control board. Corrected settings by turning off dip switches 1 and 4, while activating dip switches 2 and 3 per manufacturer specifications. Verified proper system operation with supply air temperature measuring 57.2°F at register, confirming adequate cooling performance and resolving the issue.
Responded to no cool condition on 10+ year old unit blowing hot air. Diagnosed and replaced failed capacitor and thoroughly cleaned plugged condenser coil to restore proper system operation and cooling performance.
Relocated Rheem Platinum water heater approximately 4 inches to the right to provide adequate clearance for furnace filter access and replacement. Repositioned unit with all copper supply lines, fittings, and connections maintained in proper working order.
Completed comprehensive AC tune-up and maintenance inspection on Bryant condensing unit and Lennox thermostat system. Verified thermostat operation and programming, inspected air filter condition, examined blower assembly components, tested electrical connections including contactor and capacitor, checked condensate drain line for proper flow, and measured refrigerant performance with temperature split readings. Noted outdoor coil requires cleaning due to accumulated debris and dirt buildup. All electrical readings, refrigerant levels, and system performance measurements within manufacturer specifications with no mechanical defects or safety hazards identified. System currently operating properly. Recommended maintaining regular filter changes, scheduling periodic coil cleaning for both indoor and outdoor units, and continuing routine preventive maintenance to ensure optimal efficiency and longevity.
Responded to service call for zone valve malfunction. Replaced defective zone valve power head on hydronic heating system. Accessed equipment in basement mechanical area, removed failed actuator, and installed new power head assembly. Verified proper valve operation and system functionality upon completion. Total repair time was approximately 3 hours.
Performed home sale inspection on 20-year-old furnace and air conditioning system. Furnace inspection revealed critical safety hazard with carbon monoxide levels exceeding 700 ppm in the flue due to secondary heat exchanger rusted through from inside out, causing carbon monoxide leakage into living space. Additional findings included failing flame sensor and ignitor, plus control board exhibiting burn marks around resistors. Unit red-tagged as unsafe to operate. Air conditioning inspection showed system fully operational with proper refrigerant charge, 19-degree temperature split across evaporator coil, and all components testing within manufacturer specifications. Scheduled furnace replacement estimate. Recommend immediate furnace replacement due to life safety concerns.
Responded to a floor drain backup occurring when the washing machine was in use. Upon inspection, diagnosed debris buildup in the drain line restricting proper flow and causing the floor drain to overfill. Utilized a flex shaft machine to clear the obstruction from the drain line, running water simultaneously to flush debris and restore proper drainage. Tested the system by filling and dumping the laundry tub multiple times to verify the floor drain no longer overflowed, confirming all components were functioning correctly upon completion.
Responded to main bathroom faucet repair request. Upon inspection, identified loose faucet handles and deteriorated aerator causing improper water flow. Adjusted both hot and cold water handles to restore proper operation, replaced faulty aerator, and replaced worn washer to eliminate leak. All fixtures tested and confirmed functioning properly upon completion.
Responded to water leak under kitchen sink occurring intermittently without sink or dishwasher use. Upon inspection, identified backed-up drain line causing water to overflow from P-trap assembly when water softener discharged. Confirmed drain blockage was preventing proper drainage of softener discharge water, resulting in backup through sink drain system. Documented plumbing configuration including white PVC P-trap assembly, supply lines, and connections. Scheduled drain technician for follow-up service to clear obstruction and restore proper drainage function.