We’ve assisted homeowners for over 65 years and will proudly service your home as well.
Plymouth typically experiences winter temperatures between 15 and 25 degrees Fahrenheit. So, if you wake up to discover your heater has died, you’ll need it repaired immediately. Fortunately, our furnace experts have the expertise you need. Enjoy small-town charm and reasonable prices when you reach out to us.
We Offer a Wide Range of Heating Services for Your Home, Including:
- Heating Repairs: Having your heater suddenly stop working is very inconvenient. Even a small issue can become a major problem if you don’t take action fast. Let our team of professionals correct the problem.
- Heating Installation: Are you looking for a new heater? Whether it’s the middle of the winter or summertime, we can help! Head to Emagine Willow Creek to catch a movie as we install your brand-new heater.
- Heating Maintenance: When was the last time you had preventative heating maintenance? Believe it or not, this is the best way to reduce your overall repair expenses. Plus, when you join the Hurlburt Family Rewards Club, you’ll get a discount on our services.
The temperature in Plymouth hovers around 80 degrees during the summer months, along with moderate to high humidity. Therefore, it’s always an issue when an AC stops working. Rather than dealing with your uncomfortable home, why not call us for expert cooling services and then go to Mulligan’s Indoor Golf? We’ll return cool air to your home as you enjoy yourself.
You Can Trust Our Lineup of Helpful Cooling Services for Your Home:
- Cooling Repairs: Is your AC blowing warm air or making excessive noise? Let our professional cooling experts take care of the problem. We’ll make sure your home cools off properly before we leave.
- Cooling Installation: Sometimes, it’s more cost-effective to install a new AC than to repair your old one. We’ll recommend the right-sized AC for your living environment. Go puzzle out an escape room at Breakout Games while we install your brand-new AC.
- Cooling Maintenance: Scheduling regular preventative maintenance will help you avoid major unexpected repairs. It’ll also keep your energy costs in line plus make your home comfortable. Ask about our Hurlburt Family Rewards Club to save even more.
Taking care of your plumbing is the best way to avoid a flooded house. Therefore, whether you have a tiny leak or a bigger problem, call us right away. Our professional plumbers will assist you by ensuring your plumbing works properly again. Steer clear of the many issues associated with a flooded home, including mold.
We have trained electricians on staff to help make sure your home gets wired correctly. After all, issues such as buzzing or dimming could eventually lead to a fire. Therefore, take control of your electricity by having us check it out. Any problems are immediately addressed for your peace of mind.
We’re Your Go-to Company When You Need Electrical Services:
- Electrical Repairs: Are you experiencing a burning smell or loose outlets? Both of these indicate that something is wrong with your electricity. We’ll fix it for you right away to provide peace of mind.
- Electrical Installation: Our electricians install new lighting fixtures, ceiling fans, and EV chargers. Plus, we take care of whole-home generators, circuit breakers, and carbon monoxide detectors. Our experts will make your home a more friendly, usable environment.
Plymouth is one of the largest cities in Minnesota. The good news is this means you can always find something to do. For example, if we’re repairing your plumbing, you can take a nature walk at Clifton E. French Regional Park. Or, if we’re installing a new AC, you can go enjoy craft beer
at Luce Line Brewing. Prefer to do something educational? Check out the Plymouth Historical Museum while we take care of your heater.
Choose Hurlburt whenever you need electrical, plumbing, heating and cooling services. Our team of more than 60 professionals includes professional plumbers and electricians. We also have 65+ years of industry experience, and all installations include a 12-month warranty. We provide high-quality work, and we always put people first.
Are you looking for an electrical, plumbing, or HVAC company in Plymouth? Reach out to our team of experts today!
Hurlburt Heating & Plumbing has completed 20 jobs in Plymouth, MN between July 2026 and August 2026.
The most recent job was on August 26, 2026.
Responded to no-cool complaint on 25-year-old zoned HVAC system with inadequate cooling on second floor. Performed comprehensive diagnostic testing including zone damper operation, temperature split measurement, blower speed verification, and refrigerant level assessment. All system components tested within manufacturer specifications with 20-degree temperature split confirming proper airflow and refrigerant charge. Zone dampers operating correctly and blower fan speeds set appropriately. Identified dirty outdoor coils causing reduced efficiency and increased system workload. Determined insufficient cooling likely attributed to recent flooring removal exposing subfloor, which absorbs heat and increases cooling load on upper level. System operating as designed with no mechanical failures found. Recommended switching to MERV 8 rated air filter to reduce air restriction and improve system performance. Scheduled future estimates for humidifier replacement, air exchanger installation, whole
Responded to emergency call for frozen pipe burst that caused basement flooding. Assisted with temporary rough-in plumbing work in affected area, including removal and disposal of damaged existing piping. Performed comprehensive rough-in installation throughout multiple rooms including bathroom, laundry room, and mechanical room. In bathroom, rebuilt vanity drain and DWV system, installed ADA-compliant toilet, and installed customer-supplied tub with shower valve, spout, and head. In laundry area, installed washing machine valve, rebuilt laundry tub drain, and installed deck-mount faucet. In mechanical room, installed freeze-proof hose bibb with up to 15 feet of PEX tubing, installed new water main with shutoffs as required up to 50 feet, and completed associated rough-in work. Pulled baseboard covers in bedroom, laundry room, and bathroom to access work areas. All work completed and inspected per code requirements.
Completed scheduled heating maintenance on 10-year-old Bryant HVAC system. Performed comprehensive tune-up inspection with no issues identified. Verified Bryant Evolution Connex thermostat operation at 75°F setpoint and tested system diagnostics at condensate drain line using digital measurement tools to confirm proper operation and drainage function.
Performed annual cooling maintenance on a 21-year-old air conditioning system. Upon inspection, identified a faulty contactor exhibiting buzzing and pitting, which was replaced to restore proper operation. All other system components, including refrigerant levels, tested within manufacturer specifications and are functioning correctly. Unit is fully operational following service completion.
Performed second opinion diagnostic on 10-year-old residential air conditioning system experiencing declining performance and increased energy consumption due to neglected maintenance. Upon inspection, identified failed capacitor and failing compressor on outdoor condensing unit. Due to the age of the system and cost-effectiveness of repair versus replacement, recommended and completed full HVAC system replacement.
Completed annual cooling maintenance on three commercial rooftop units. Replaced all return air filters (4 ea. 18x24x2 and 8 ea. 16x16x2), cleaned condenser coils with water, cleared condensation drain lines, and inspected compressor and condenser fan motors. All units operating normally with proper cooling function verified; no issues found.
Completed temporary installation and hook-up of washer and dryer units at service location. Connected water supply lines, drain hoses, and verified proper positioning of appliances for operational testing.
Responded to humidity concern on less than one-year-old Lennox HVAC system. Upon arrival, performed diagnostic evaluation of whole-house humidity levels. Tested system operation and confirmed heating and cooling functions operating normally. Checked thermostat humidity settings and found current setting at 76 percent. After consulting with homeowner regarding comfort preferences, adjusted thermostat humidity setpoint to 80 percent per customer request. Verified HVAC system equipped with Healthy Climate Solutions Carbon Clean 16" air filter (HCF16-16, 16"x25"x5"). Inspected outdoor condenser unit installed on concrete pad against home exterior; unit showing normal operational wear with debris accumulation on top surface. No mechanical deficiencies identified. System operating as designed with adjusted humidity parameters meeting customer requirements.
Responded to no cooling complaint on Carrier system. Diagnosed ECM blower motor failure after observing humming noise from furnace with no air movement, while outdoor unit operated normally when thermostat wires were jumped. Replaced defective ECM blower motor and restored system to normal operation. Discussed system replacement options due to unit age and provided information for future equipment upgrade consideration.
Completed preventive maintenance agreement service on commercial HVAC system consisting of two rooftop units. Accessed rooftop equipment via building maintenance stairway. Replaced return air filters on both RTUs with 20x25x2 filters. Cleaned condenser coils on both rooftop units and performed thorough cleaning of pre-filters and condensate drain traps. Verified fan operation and cooling functionality on all equipment. All systems tested and operating within normal parameters upon completion of maintenance tasks.
Completed comprehensive 8-12 point tune-up on residential air conditioning and furnace system for preventive maintenance agreement member. Documented equipment makes, models, and serial numbers with detailed photographs of all HVAC components including furnace unit, air handler, and associated ductwork. During inspection, identified refrigerant charge slightly below optimal levels on AC system; noted system may require refrigerant addition or potential replacement consideration for future service planning.
Responded to no cooling call on 6-year-old AC system. Diagnosed failed capacitor as root cause of system malfunction. Replaced defective capacitor under warranty, restoring proper system operation and cooling functionality.
Responded to no-cool complaint on 6-year-old system for second opinion after another company reported rodent damage and low refrigerant. Upon arrival, thermostat was at setpoint of 72°F. Performed comprehensive system evaluation including air filter inspection, blower motor operation, outdoor unit coil condition, capacitor, contactor, and refrigerant charge verification. Located wire damage from rodent activity at outdoor unit; confirmed damage was limited to protective sleeve only with conductors intact. Secured exposed wiring with electrical tape. Measured supply/return air temperature delta at 19°F, confirming proper system performance. All components operating within normal parameters with no refrigerant loss detected. Explained that previous temperature issues likely resulted from extreme outdoor conditions (90°F+), heat gain from kitchen activities, and inadequate ductwork coverage to home addition near thermostat location rather than equipment malfunction. System operating prope
Responded to a toilet backup affecting only the fixture, with no impact to other drains in the residence. Upon arrival, removed the toilet to access the drain line and identified a toilet paper blockage located near the fixture connection. Utilized drain cable equipment to clear the obstruction, making multiple passes to ensure complete removal of the blockage. Verified proper drainage and line clearance using camera inspection equipment. Reinstalled the toilet with new wax ring seal, secured mounting bolts, and tested for proper flushing operation and water flow. Confirmed no leaks present at base or supply connections and verified system functioning normally upon completion.
Installed new brushed stainless steel kitchen faucet with high arched spout at single-family residence. Connected faucet supply lines to existing shutoff valves and verified proper water flow and drainage through double-basin stainless steel sink. Cleared basement toilet obstruction using closet auger, restoring proper flush function and drainage.
Responded to gas leak emergency at residential property where gas supply had been shut off for safety. Located and identified leak at underground fitting near fence line that connected two gas lines. Presented options to either cap the leaking line or replace the entire gas line run, with sales team scheduled to provide quote for new gas line installation from meter along house to deck grill location.
Completed annual cooling maintenance on 9-year-old air conditioning system. Replaced failing capacitor, outdoor temperature sensor batteries, and malfunctioning main level zone thermostat that was causing continuous fan operation when system was off. Verified all other components operating within specifications with proper refrigerant levels and system confirmed operational upon completion.
Responded to callback for excessive indoor humidity levels reading at 73%. Adjusted system airflow from 1200 CFM to 1050 CFM and disabled dehumidification mode on Lennox thermostat to optimize system performance. Upon adjustment, indoor humidity decreased to 69% with system cooling to setpoint of 70°F.
Responded to callback for air conditioning system not cooling. Upon arrival, found furnace control board not powered and 24V fuse open. Reset fuse and cycled system to restore operation. Performed comprehensive system check including thermostat wiring, control board connections, condenser operation, and capacitor testing—all components functioning within normal parameters. Addressed thermostat programming concerns by removing batteries, verifying C wire connection, and instructing occupants on proper use of Hold function to override scheduling feature. System restored to normal cooling operation.
Responded to no cooling complaint on residential split system air conditioning unit. Upon arrival, verified thermostat was calling for cooling at 75 degrees setpoint. Inspected air filter and blower speeds, both found satisfactory. Observed outdoor unit contactor not receiving 24V control voltage from thermostat, though 240V line voltage was present. Tested capacitor, found within specifications. Discovered outdoor coil heavily blocked with cottonwood debris, restricting airflow. Cleaned condenser coil thoroughly, restoring proper airflow. Replaced thermostat batteries and verified wire connections secure. During further inspection, found blower operating at lowest speed setting and reset button on furnace door switch tripped. Reset safety switch, restoring unit operation. Cycled power to system by disconnecting and reconnecting wiring to confirm proper startup. Checked refrigerant charge and found system operating below optimal levels. Measured supply and return air temperature diffe