Responded to health inspector compliance issue by installing an air gap on food prep sink that was previously connected incorrectly. Attempted to address two urinals with slow drainage but determined they required professional drain cleaning. Referred client to Roto Rooter for urinal service as the blockage was beyond standard maintenance capabilities.
Performed annual furnace tune-up on 2-year-old FRP heat pump system. Replaced dirty humidifier pad and filter. Inspected all components including blower (clean and balanced), electrical components (within spec), condensate lines (clear), and heat exchanger (no compromises). System operated normally during 15-minute test run with 60-degree temperature rise. Reviewed whole home dehumidifier operation with customer per their request.
Performed routine furnace tune-up on 8-year-old FRP unit. Inspected components including filter (noted as requiring replacement), blower (clean and balanced), and heat exchanger (no compromises). Identified leaking inducer seal at collector box causing noise and potential electrical hazard. Tested system operation for 20 minutes with proper gas pressures and verified venting integrity. Customer requested estimate for inducer motor repair.
Performed furnace tune-up on a 17-year-old natural gas regulator that was improperly installed for an LP gas single-stage furnace serving three zones. Inspected the heat exchanger and condenser coils, noting debris accumulation requiring cleaning. Examined the Honeywell digital thermostat which was functioning properly with correct temperature readings. Customer indicated limited interest in full system replacement at this time.
Completed duct cleaning service as part of installation package. Inspected and cleaned ductwork connected to wall-mounted air vents, ensuring proper airflow and system efficiency. Verified installation integrity of rectangular metal vent access points throughout the home.
Performed comprehensive duct cleaning service in conjunction with new HVAC system installation. Cleaned and inspected all accessible supply and return air vents throughout the property, ensuring proper airflow and system efficiency.
Completed annual HVAC maintenance on 19-year-old gas furnace for new customer. Inspected heat exchanger which appeared in acceptable condition despite age, with evidence of previous repairs. Noted adjacent 80-gallon water heater with visible leak dripping onto floor from pedestal. Customer scheduled follow-up appointments for equipment replacement quotes for both HVAC and plumbing systems.
Performed scheduled maintenance on geothermal system including temperature readings, pressure verification, and component inspection with all systems functioning properly. Conducted thorough inspection of G32 gas furnace including heat exchanger examination, flame sensor and condensate cleaning, with no defects identified. Serviced steam humidifier which exhibited frequent flushing cycles due to ongoing water conductivity issues, and performed maintenance on separate oil furnace including nozzle and filter replacement.
Responded to no-heat complaint on dual electric/oil furnace system. Diagnosed failed electric plenum heater with burnt contactors and 24V coils as confirmed by visual inspection. Customer has been relying on oil furnace for heat. After discussing repair options, customer elected to discontinue electric heating repairs in favor of converting to LP due to high utility costs from electric heat usage. Scheduled advisor visit for LP conversion consultation.
Responded to no heat complaint on 5-6 year old LP furnace. Diagnostic testing revealed gas valve was not energizing despite receiving 26 volts. Replaced gas valve under warranty coverage and verified proper system operation with successful heat production.
Responded to service call for handicap toilet in men's restroom that was overflowing. Diagnostic inspection revealed broken flush valve component. Shut off water supply, disassembled tank, and replaced defective flush valve part. Tested toilet operation after repair to confirm proper function with no further leaking or overflow issues.
Connected commercial stainless steel utility sink to waterline in utility room. Installed single basin sink with backsplash against wall, ensuring proper water connections. Verified system functionality after installation.
Responded to service call for a clogged urinal. Disassembled the urinal fixture, performed drain snaking procedure to clear the blockage, then reassembled the unit. Verified proper drainage function before completing the service.
Inspected Navien tankless water heater (model NPE2400) exhibiting error codes and found significant corrosion around the recirculation pump and heat exchanger. Recommended tuneup service to address these issues. Also assessed backing up urinal and recommended augering to clear the blockage.
Performed scheduled oil furnace tune-up on 10-2 oil furnace per maintenance agreement. Discovered incorrect nozzle size (.75 installed when .65 was required per burner specifications) and soot buildup in pipes and inspection hall. Replaced with correct nozzle size, vacuumed chambers, inspected heat exchanger, and adjusted air-fuel mixture. Unit is now operating efficiently with proper combustion.
Performed annual furnace tune-up on 3-year-old system. Inspected and verified clean filter, balanced blower, electrical components, heat exchanger integrity, and proper roof ventilation. Confirmed appropriate gas pressures and verified proper operation of first and second stage cycling during 15-minute test run. System functioning normally with no issues identified.
Performed annual Family Rewards furnace tune-up on 3-year-old Lennox system. Conducted comprehensive inspection including electrical components, heat exchanger, gas pressure verification, and blower assembly - all functioning within specifications. System demonstrated proper 50-degree temperature rise during 20-minute operational test with no issues identified.
Completed site visit to estimate installation of customer-supplied commercial produce sink. Discovered installation challenges including lack of accessible drainage and water supply lines, with only limited access through tight quarters behind wall. Documented existing space and utility access points to develop comprehensive installation plan.
Water heater
I was called to a home to repair an electrical panel that was not working. Upon arrival, I found that the circuit breaker had tripped. I checked the wiring and found that a wire had been damaged. I replaced the damaged wire and tested the circuit breaker. The circuit breaker is working properly again for the home.