We’ve assisted homeowners for over 65 years and will proudly service your home as well.

Snowy weather turns Mound into a winter wonderland, but it’s hard to appreciate the beauty of areas like Hyland Hills if you don’t have a reliable heating system at home. Whether you hit the slopes, skate on Cooks Bay, or go fishing at Lake Waconia, you want your house to be a warm haven to return to. With our expert services, you can save money on heating costs and never worry about breakdowns during a Minnesota cold snap.
We’ll Keep You Warm With:
- Heating repair: Worn-out heat exchangers, blower motors, and pilot lights cause breakdowns and raise your heating costs. Our repair services target all of these problems and more.
- Heating installation: Need a new heater installed? We install systems of all types, including gas and electric furnaces, boilers, and heat pumps.
- Heating maintenance: Members of the Hurlburt Family Rewards Program receive annual heating maintenance to avoid breakdowns. You also get perks like discounts on repairs, parts, and accessories.
Refrigerant leaks and other AC problems, like clogged air filters, can be harmful to your health. They can also make it impossible to keep your home cool. We want to help you create a home that always stays cool during warmer weather. You’ll feel better and have more energy to enjoy all that Mound has to offer, like swimming at Surfside Park and kayaking on Lake Minnetonka.
Enjoy Efficient Cooling Services:
- Cooling repair: A malfunctioning AC can raise energy bills and take the fun out of the Minnesota summer. Our repairs restore efficiency by fixing refrigerant leaks, worn-out parts, and other problems.
- Cooling installation: Choosing a home cooling system can be overwhelming. We offer expert advice and can answer all your questions to help you make the right decision for your family. Count on us to install your new system with all the care you deserve.
- Cooling maintenance: To extend the life of your air conditioner and reduce its energy use, join the Hurlburt Family Rewards Program. Our annual tune-ups can help you prevent costly problems.
When water leaks in your home, it can severely damage the walls, floors, and foundation. Leaks also create wet situations where mold can grow. We can put your worries about these problems to rest. We are experts at finding hidden leaks in places like basements, crawl spaces, and attics. Our water treatment solutions help soften Mound’s hard water supply and reduce chemical contaminants.
There are lots of electrical upgrades that will make your house more secure and convenient. We can add outdoor security lighting for enhanced safety and EV chargers so you can skip the lines at Mound’s public chargers. We can add smart outlets so you can control all your devices from your phone. And if something goes wrong, call us for expert electrical repairs to get your home safe, reliable, and powered up again.
Turn to Us for Fast, Effective Electrical Work:
- Electrical repair: Get fast repairs so you can keep using your TVs, appliances, lights, and outlets. We fix everything from faulty wiring to circuit breaker issues.
- Electrical installation: You need a qualified electrician for installations to ensure safety, lasting work, and code compliance. We can add generators, light fixtures, outlets, circuit breakers, ceiling fans, and more.
We make it easy to access our services in all parts of Mound. Our employees genuinely care about the community and strive to create comfortable, safe, and efficient homes. Whether you’ve got a broken water heater in a house near Carbone’s or have a busted AC in your waterfront home, call Hurlburt. We’re ready to help!
We are proud to deliver outstanding, detail-oriented service to each and every customer. Our skills and knowledge are important, but our devotion to exceeding expectations is why our customers make us their home service partners for life.
For over 65 years, we haven’t wavered in our commitment to an exceptional level of home care. From furnace repair and toilet installation to EV charging stations, we don’t just fix and transform houses. We make sure you feel cared for!
Call Hurlburt now to speak with Mound’s most compassionate plumbing, electrical, and HVAC company. Welcome to the Hurlburt Family!
Hurlburt Heating & Plumbing has completed 20 jobs in Mound, MN between June 2026 and September 2026.
The most recent job was on September 24, 2026.
Completed annual preventative maintenance heating visit on one gas furnace (2023 model), one gas fireplace, and one humidifier. Performed comprehensive tune-up procedures including inspection of heat exchanger fins and internal ductwork components. Replaced dirty air filter with customer-supplied filter. All equipment operating within normal parameters with no deficiencies noted.
Responded to gas leak emergency at dryer connection where gas company had identified hazardous condition and shut off gas supply. Found damaged hard line to dryer and leaking gas valve in poorly accessible location. Replaced faulty gas valve and relocated to more accessible position for improved safety and future serviceability, restoring safe gas service to appliance.
Responded to multiple gas leak calls at property with two furnaces. Located and repaired gas leaks on copper flare connections at garage furnace, leak on tee fitting near meter, and drip cap on furnace bypassing Maxitrol valves at both units. Pressure tested all gas lines after repairs and confirmed system passed leak test with no further issues detected.
Responded to service call for malfunctioning water softener and iron filter system. Upon inspection, found corroded control board on water softener unit and completely plugged iron filter system. Disconnected and removed failed control board, installed warranty replacement unit, and reconnected all wiring. Verified proper electrical connections and system functionality through testing protocol. Addressed severely clogged iron filter tower by performing heavy flush and thorough cleaning to remove accumulated iron buildup and debris. Cleared plugged discharge line and restored proper drainage flow. Ran complete regeneration cycle on system and conducted water quality testing to confirm iron levels returned to acceptable parameters. All components tested and verified operational upon completion.
Completed biannual preventive maintenance plumbing inspection including draining and testing exterior faucets, water heater cleaning, sump pump inspection, and laundry hose evaluation. Inspected under-sink filtration system and noted aging equipment, though all other plumbing components found to be in good working condition. Provided estimate for replacement comfort height round toilet installation.
Completed annual cooling maintenance on 6-year-old Trane high velocity attic system. Performed comprehensive tune-up including refrigerant level verification, component testing, and operational assessment. All components tested within manufacturer specifications, refrigerant charge confirmed at proper levels, and system found to be fully operational with no deficiencies noted.
Completed comprehensive air conditioning tune-up and preventive maintenance inspection per family rewards agreement. Performed standard seasonal maintenance protocol including system diagnostics, component inspection, and operational testing of HVAC equipment. All systems operating within normal parameters with no deficiencies identified or corrective actions required.
Responded to water leak in utility room originating from pipe connected to outside faucet. Upon arrival, water supply was already shut off. Inspection revealed leaking inside hose bib valves caused by loose bleeder valve caps that had not been properly tightened. Tightened all bleeder valve caps to manufacturer specifications, resolving the leak issue.
Serviced a 5-year-old Northstar water softener system that had never received maintenance and was experiencing operational issues with iron deposits and water conditioning problems. Diagnosed and addressed electrical contact failures, replaced faulty nozzle and venturi assembly which was significantly clogged with mineral buildup. System was cycled and homeowner instructed to monitor performance before scheduling follow-up appointment to verify proper operation.
Responded to service call for banging noises in plumbing system associated with tankless water heater operation. Upon inspection, identified severely clogged water filter as primary cause of water hammer and pressure fluctuations. Removed and cleaned filter housing, confirmed hot water system remained operational throughout service. Diagnosed irrigation line routing conflict that was contributing to pressure issues at filter location. Rerouted irrigation line to bypass filter assembly, eliminating interference with main water supply system. Tested all connections for leaks, verified proper water pressure restoration throughout system, and confirmed elimination of banging noises during water heater operation.
Completed annual AC tune-up and maintenance inspection on residential HVAC system as part of preventative maintenance agreement. Performed comprehensive system evaluation, verified proper operation of all components, and documented equipment specifications including 20x25x4 filter size and airflow direction. No deficiencies identified; unit operating within normal parameters.
Completed routine maintenance tune-up on Daikin outdoor air conditioning condenser unit under service agreement. Inspected dual-run capacitor (45/5 µF, 370VAC), verified proper electrical connections, and confirmed all system components operating within normal parameters with no issues identified.
Responded to no cooling complaint on 22-year-old Bryant air conditioning system. Performed diagnostic testing and found elevated suction pressure with low subcooling and no superheat readings. Verified proper airflow across evaporator coil with approximately 13-degree temperature split. Diagnostics indicated thermostatic expansion valve (TXV) overfeeding refrigerant to evaporator coil, consistent with stuck valve or defective sensing bulb. Inspected all other system components and confirmed no additional issues. Due to R22 refrigerant system and company policy discontinuing service on R22 equipment, unable to perform repair. Scheduled service advisor consultation to discuss system replacement options.
Responded to low water pressure issue caused by sediment and debris buildup in the water line. Performed diagnostics and determined the existing whole house inline sediment filter cartridge required replacement. Removed old filter cartridge and installed new 20-inch by 4.5-inch whole house inline sediment filter cartridge to restore optimal water flow and system performance. Upon completion, restored water supply and conducted thorough leak inspection of filter housing and connections with no leaks detected. System returned to full service with improved water pressure and flow characteristics.
Responded to no cooling complaint where system was blowing warm air. Upon inspection, diagnosed failed dual run capacitor in outdoor condensing unit. Replaced defective capacitor with new unit per manufacturer specifications. Verified proper electrical connections, tested system operation, and confirmed unit cooling properly before departure.
Responded to low water pressure complaint affecting entire home, particularly during morning hours. Upon inspection and consultation, determined that a severely clogged whole home water filter was restricting flow throughout the plumbing system. The pressure issue was most noticeable in the mornings when the outdoor sprinkler system was operating simultaneously, creating compound demand on the already-restricted water supply. Removed and inspected the filter cartridge, which showed heavy sediment accumulation and discoloration throughout the filter media, confirming significant blockage. Created parts order for replacement filter cartridge and placed existing filter system in bypass mode to restore immediate water pressure to the home while awaiting the new cartridge. Documented filter condition with photographs showing the extent of sediment buildup on the cylindrical cartridge. Replacement filter installation will be scheduled upon parts arrival to restore full filtration capacity t
Completed annual cooling tune-up on Mitsubishi Electric mini-split system with one outdoor condenser unit and four indoor air handler heads. Performed comprehensive maintenance including filter cleaning on all heads, drain line flushing, and temperature split verification testing both individually and with all heads operating simultaneously. All heads achieved optimal 25-degree temperature splits, confirming proper system performance. Noted that the master bedroom head will require deep cleaning during next year's scheduled maintenance visit.
Completed annual air conditioning tune-up and maintenance inspection on 8-year-old Rheem AC system. Performed comprehensive system evaluation including contactor inspection, capacitor testing, condenser coil rinse, temperature drop analysis (19 degrees indicating proper refrigerant charge), amp draw verification, air filter check, evaporator coil inspection, blower wheel examination, control board assessment, and condensate line clearance verification. All components tested within normal operating parameters with no deficiencies identified or recommendations required at this time.
Completed annual preventive maintenance cooling visit on single AC system under maintenance agreement. Upon inspection, found rooftop unit with heavily soiled evaporator coils containing significant debris accumulation including leaves and organic material. Performed comprehensive tune-up including system evaluation, cleaning of components, and refrigerant level check. System was found to be low on refrigerant; recharged unit to proper operating levels. Verified thermostat operation and system functionality upon completion. All components tested and operating within normal parameters following service.
Responded to no cooling condition on multi-zone Daikin HVAC system where unit was running but delivering warm air. Upon diagnosis, identified failed zone control board with missing terminal clip causing two zones to be improperly tied together. Replaced defective zone board and restored proper system operation.