Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
Menomonie has a wide range of housing styles and ages, which creates a unique mix of heating, cooling, plumbing, and electrical needs. Older homes near downtown and the university area often still rely on aging infrastructure, while newer homes near the south side and Cedar Falls Road continue adding modern Heating and Cooling systems, generators, smart home technology, and upgraded electrical service.
A lot of plumbing work in Menomonie comes back to the age of the homes and the way the city has expanded over time. Around the older neighborhoods near downtown, Wilson Avenue, and the university area, we regularly work on aging drain lines, outdated shutoffs, older water heaters, and plumbing systems that have been modified multiple times over the years.
On the newer side of town, homeowners are often calling about water softeners, sump pumps, filtration systems, and plumbing upgrades tied to remodels and additions.
If your plumbing system is giving you problems, we can help.
The average heating and cooling repair service costs from $100 – $1,000 or more depending on what needs to be fixed. If you have a simple fan blade that is broken, your repair will be much less than it would for a condenser replacement, for instance.It’s important to always have a licensed technician fix your system; that way, you won’t have to worry about additional problems and expensive repairs down the road. Our team at Hurlburt is fully licensed and insured for you. Contact us today to learn more or to schedule your A/C repair service!
A/C and Furnace installation can cost between $4,000 – $10,000 in and around Menomonie, WI. This price includes the unit as well as labor costs. The cost will be affected by a few things:
Are you interested in a new Heating and Cooling system? Call the team at Hurlburt today for a FREE estimate!
Some common plumbing problems that many homeowners near Menomonie, WI face include:
Here at Hurlburt, we can help you with any of your home’s plumbing concerns. Just connect with one of our friendly team members today!
Electrical systems in Menomonie homes vary more than most people realize. We might spend the morning upgrading an older panel near downtown and then head out toward newer developments near Highway 12 to install EV chargers or backup generators.
A lot of older homes throughout Menomonie still operate with panels and wiring that were never designed for modern electrical demand. Once homeowners start adding newer appliances, Air Conditioning and Heating systems, or home office equipment, those limitations start showing up quickly.
Heating season in Menomonie is long enough that homeowners usually notice problems before winter is even halfway over. We spend a lot of time working on aging furnaces, older boilers, and systems that struggle to maintain even temperatures once the colder weather settles in.
Homes around the older parts of Menomonie often have airflow limitations, undersized ductwork, or heating systems that have been patched together over decades of repairs and upgrades.
Menomonie homeowners deal with completely different air quality concerns depending on the season. During the winter, homes dry out fast once the furnace runs constantly. During the summer, humidity becomes the bigger issue, especially around lower areas near Lake Menomin and the Red Cedar River.
We also see a lot of dust buildup and airflow issues in older homes with aging duct systems.
The right humidity and filtration setup can make a noticeable difference in comfort year-round.
Cooling problems in Menomonie usually come down to airflow, humidity, or older systems trying to cool homes that were never originally built for central air. We work on a lot of older houses where the AC system was added years later, which often leaves upstairs rooms warmer and airflow inconsistent.
The humidity around Menomonie can also make systems run longer than homeowners expect, especially during stretches of hot weather in July and August.
Ductless mini-splits have become a popular solution throughout Menomonie for older homes, finished basements, additions, and garages.
Menomonie is already part of our daily service area. Our technicians know the neighborhoods, the older housing stock, and the common repair issues homeowners here deal with every year.
From homes near Broadway Street and downtown Menomonie to properties closer to Cedar Falls Road and the south side developments near I-94, we are already servicing homes throughout the area every week.
Responded to a water heater emergency where the existing unit was leaking from the bottom due to age-related deterioration. Upon assessment, determined the tank had failed and required full replacement rather than repair. Removed the old water heater and installed a new 40-gallon natural gas standard vent water heater manufactured by Bradford White Corporation. Connected all gas lines, water supply lines, and venting per manufacturer specifications and local code requirements. Verified proper operation, checked for leaks, and ensured all safety controls were functioning correctly before completing the installation.
Responded to no cooling complaint on 7-year-old Evcon system under maintenance agreement. Diagnosed failed capacitor preventing condenser from starting. Replaced defective ProSelect capacitor and verified proper system operation with all components functioning correctly.
Responded to emergency call for leaking water heater causing flooding in basement. Upon arrival, inspected 5-year-old tank-style water heater and confirmed active leak originating from bottom of unit. Determined water heater had failed prematurely and was beyond repair. Removed defective water heater from premises to prevent further water damage to basement floor and surrounding area.
Responded to no hot water call for 5-year-old IBC boiler system controlling all domestic hot water through indirect-fired water heater. Upon arrival, found boiler control in fault condition. Reset and reconfigured the control system, then performed comprehensive diagnostic tests on all heating zones and loads to verify proper operation. System ran successfully through test cycles, but observed pressure relief valve dripping after extended runtime. Replaced defective temperature and pressure relief valve to prevent water loss and maintain safe system operation. Confirmed all zones functioning correctly and hot water restored to residence.
Responded to service call for leaking evaporator coil in HVAC system. Diagnosed refrigerant leak at evaporator coil and determined replacement was necessary. Removed failed evaporator coil and installed new replacement unit. Evacuated system to proper vacuum levels, recharged with appropriate refrigerant amount, and added UV dye for future leak detection. Verified all connections were secure and system operation was restored to manufacturer specifications with proper cooling performance.
Responded to a plumbing correction where a hose bibb had been incorrectly connected to the softened water supply line instead of the hard water line from the well. Upon inspection, determined that the hose bibb was never properly piped to hard water when the water softener system was originally installed. Rerouted copper piping to connect the hose bibb directly to the hard water supply, bypassing the water softener system to provide untreated well water for outdoor use and prevent unnecessary wear on the softening equipment.
Completed routine HVAC maintenance agreement service on residential system including one furnace and air conditioning unit. Performed comprehensive AC tune-up with outdoor condenser coil washing, electrical system testing and verification of proper operation. Indoor air handler and outdoor condensing unit inspected with all components functioning within normal parameters and no issues identified.
Responded to low water pressure complaint affecting upstairs shower. Upon inspection, identified sediment buildup obstructing the shower faucet cartridge. Flushed waterline to remove debris and installed new cartridge to restore proper flow. Tested system water pressure and confirmed reading of 30 psi, which is below optimal residential standards but consistent with recent municipal water supply issues in the area.
Responded to service call for two malfunctioning toilets in residential property. Downstairs toilet experiencing continuous running issue was repaired by adjusting fill valve and removing accumulated sediment from tank, restoring proper operation. Upstairs toilet with chronic drainage problems requiring frequent plunging was replaced with new Gerber ADA-compliant unit due to age and deterioration of original 40-year-old fixture. During installation, identified soft subfloor condition and applied silicone sealant around toilet base to stabilize fixture and prevent movement. Advised property owner that underlying floor structure may require future repair or reinforcement if stability issues persist.
Completed annual plumbing inspection as part of recurring preventive maintenance program. Inspected all accessible plumbing fixtures and water treatment equipment throughout the residence. Examined shower valve assembly and noted age-related mineral deposits and corrosion around control mechanism, though unit remains functional. Assessed water softener system and associated plumbing connections, observing corrosion on metal fittings at cylinder connection points. All systems operating properly with no immediate repairs required at this time.
Responded to callback for mini-split system installed two days prior with flashing operation light and no cooling. Diagnosed 16-flash error code indicating refrigerant charge issue. Recovered refrigerant from system, confirming overcharge condition with 10 psi excess pressure. Evacuated system and weighed in manufacturer-specified refrigerant charge per unit specifications. System restored to operational status with improved cooling performance. Identified leaking service valves on both liquid and suction lines during diagnostic process. Documented findings and advised that unit replacement may be necessary due to defective service valves on new installation. Temporary repair completed to restore cooling capability.
Performed comprehensive duct cleaning service to remove accumulated dust and debris from the HVAC ductwork system. All accessible supply and return ducts were thoroughly cleaned using professional equipment, improving system airflow and indoor air quality.
Responded to water leak emergency caused by malfunctioning water softener unit actively spraying water from rear connections. Upon customer request, removed non-functional water softener system completely from plumbing line. Cut out existing softener unit and reconfigured supply piping to bypass treatment system, establishing direct hard water connection to household plumbing. Restored water service without filtration or softening treatment as specified by customer.
Responded to commercial kitchen sink drain issue. Upon inspection, found existing basket strainer severely corroded with broken threads, rendering it non-functional and unable to maintain proper seal. Removed deteriorated basket strainer assembly and cleaned drain opening. Installed new basket strainer with proper sealing to ensure leak-free operation and restored full drainage functionality to the commercial sink system.
Responded to no-power complaint on Arcoaire furnace system. Upon inspection, determined the lower access panel was not fully engaging the safety interlock switch, preventing unit operation. Applied electrical tape to the switch button to ensure proper contact when door is closed. Verified proper door closure and tested system operation. Unit restored to normal heating function.
Completed scheduled cooling system maintenance and inspection on residential Lennox HVAC system. Performed comprehensive tune-up including washing outdoor condenser unit, testing all electrical components and connections, and verifying proper system operation. Unit found to be functioning within normal parameters with no deficiencies noted.
Responded to a leaking outdoor hose bibb that appeared to be original to the home's construction. Successfully replaced the failed hose bibb with a new unit, eliminating the leak and restoring proper function to the outdoor water supply.
Responded to install follow-up for inadequate cooling performance with system only achieving 1-degree temperature drop over 3 hours. Performed comprehensive system diagnostics and adjusted thermostatic expansion valve (TXV) to optimize refrigerant metering. Corrected system refrigerant charge using manifold gauges to achieve proper subcooling and superheat values. Conducted complete operational testing to verify system performance and cooling capacity restored to manufacturer specifications.
Completed annual air conditioning tune-up and preventive maintenance on a 6-year-old Lennox cooling system. Performed comprehensive system inspection including electrical measurements showing 11.55 amps draw at 60 Hz, verified proper amperage within manufacturer specifications, and confirmed all components operating normally. System found functioning correctly with no deficiencies noted at time of service.
Responded to no cooling complaint on 20-year-old air conditioning system that had previously iced over. Upon arrival, unit was thawed and operational but failing to reach desired temperature setpoint. Performed diagnostic evaluation and identified system was low on R22 refrigerant. Conducted borescope inspection of evaporator coil, documenting interior condition with digital imaging that revealed moisture accumulation and oxidation staining on coil surfaces. Given the age of the unit, obsolete refrigerant type, and current system condition, recommended comfort advisor consultation for replacement options rather than repair of aging equipment.