Since 1959 Hurlburt, we make it our mission to keep your home comfortable and protected.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
Our HVAC repair services are tailored to ensure your heating, ventilation, and air conditioning systems operate at peak efficiency and comfort. Our skilled technicians possess extensive experience in diagnosing and fixing a wide array of heating and AC repair issues, from minor malfunctions to major breakdowns. We prioritize prompt response and timely repairs to restore your system’s functionality swiftly.
Our services encompass a thorough assessment of your heating and cooling system, identifying the root cause of any problems before implementing efficient and effective air conditioner and heating repair solutions. Whether it’s a faulty thermostat, a malfunctioning compressor, air duct issues, or refrigerant leaks, we have the expertise to address them all. We use top-quality replacement parts and advanced tools to guarantee lasting repairs and improved system performance.
Furthermore, we strive to educate our clients on preventive heating tune-ups and air conditioning maintenance to minimize future breakdowns and extend the lifespan of their HVAC systems. Our commitment to customer satisfaction, expertise in the field, and dedication to excellence set us apart as a trusted HVAC repair service provider.
Our HVAC installation services encompass a wide array of offerings to cater to your heating and cooling needs. Our team excels in air conditioning installation, ensuring a smooth and efficient process when integrating new AC units into your space.
If you require air conditioning replacement or are looking to upgrade to a more energy-efficient model, we’re here to guide you through the selection process and execute a seamless AC replacement. Our expertise in central air installation solutions allows for consistent and effective cooling throughout your property.
We understand the importance of a well-functioning heating and cooling system, which is why we specialize in air conditioner replacement, HVAC replacement, and furnace replacement, providing you with top-tier service to enhance your comfort and efficiency.
During the colder Wisconsin months, the humidity levels outside and inside of your home can also fluctuate. To combat this issue, we provide whole home humidifier and whole home dehumidifier options. Whether your home has an excess or a deficit of humidity, our indoor air quality servicescan provide a solution. If your home’s humidity is as it should be, but you are still seeking to improve your indoor air quality, we also offer UV light air purifier installations.
In Menomonie, WI, Hurlburt delivers a comprehensive suite of electrical services to ensure the safe and efficient operation of your home’s electrical systems.
Our expert technicians perform precise electrical repairs to solve urgent problems and install whole-home generators to provide continuous power during electrical outages.
We offer critical services for electrical panels, the cornerstone of your home’s electrical system, to protect against hazards and enhance electrical functionality. Whether you are updating your panel for additional appliances or ensuring compliance with safety regulations, Hurlburt’s team offers confidence with every visit.
We deliver outstanding electrical installation services that cater to enhancing both the comfort and functionality of your home. Whether it’s the installation of transformative new lighting or the addition of outlets to support various devices, Hurlburt’s adept team is ready to assist.
We also excel in the installation of ceiling fans, which promote a comfortable living environment and better energy efficiency. With a focus on safe and meticulous installations, Hurlburt ensures all services are implemented perfectly to integrate effortlessly into your lifestyle.
People in Menomonie, WI can enjoy duct cleaning services that boost the efficiency of air conditioning units and improve the air quality their your home. When ducts accumulate dust, allergens, and debris, they can obstruct airflow and diminish HVAC efficiency.
Hurlburt’s duct cleaning restores airflow to optimal levels, ensuring maximum efficiency of your air conditioning system. This contributes to lower energy expenditures and increased system longevity. Additionally, the enhanced cleanliness of your ducts greatly betters the air quality in your home, which minimizes irritants and fosters a healthier environment.
The average HVAC repair service costs from $100 – $1,000 or more depending on what needs to be fixed. If you have a simple fan blade that is broken, your repair will be much less than it would for a condenser replacement, for instance.It’s important to always have a licensed technician fix your system; that way, you won’t have to worry about additional problems and expensive repairs down the road. Our team at Hurlburt is fully licensed and insured for you. Contact us today to learn more or to schedule your HVAC repair service!
HVAC installation can cost between $4,000 – $10,000 in and around Menomonie, WI. This price includes the unit as well as labor costs.The cost will be affected by a few things:
Are you interested in a new HVAC system? Call the team at Hurlburt today for a FREE estimate!
Some common plumbing problems that many homeowners near Menomonie, WI face include:
Here at Hurlburt, we can help you with any of your home’s plumbing concerns. Just connect with one of our friendly team members today!
The plumbing services provided by Hurlburt are designed to cover a wide spectrum of needs, ensuring a reliable and smoothly functioning water system in your home or business. Our skilled plumbers in Menomonie, WI specialize in professional plumbing repair, addressing a range of issues from minor leaks to more complex plumbing system malfunctions.
We excel in water heater installation, making sure you have a steady and efficient supply of hot water. Our team also offers options for tankless water heaters. Whether you need plumbing service for routine maintenance or emergency repairs, we are dedicated to delivering high-quality solutions that meet your unique requirements and ensure the proper functioning of your plumbing system.
Another way we can help keep your plumbing and HVAC systems protected is with our Hurlburt Family Rewards Club. As a member of our maintenance program, you will get discounts on repairs as well as annual or semi-annual servicing. To learn more about our HVAC repairoptions and plumbing services, give us a call today. To see what our loyal customers are saying about our services, read our reviews below!
Performed comprehensive air conditioning tune-up and maintenance on 3-year-old Lennox system. Completed full system cleaning and operational check of all AC components, including inspection of electrical connections, refrigerant levels, and airflow performance. System operating within normal parameters with no deficiencies noted.
# HVAC Service Completed Responded to no cooling call on 40-year-old residential air conditioning system. Upon arrival, confirmed unit would not start. Performed comprehensive diagnostic evaluation of outdoor condenser unit, which showed significant age-related deterioration including extensive rust on fan grille and overall weathering of cabinet. Testing revealed failed contactor preventing system startup. Used digital multimeter to measure run capacitor, which tested at 24.17 microfarads, significantly below manufacturer specifications, confirming capacitor failure. Visual inspection identified failing condenser fan motor showing signs of wear and reduced operational capacity. Given the system's age at 40 years—well beyond typical 15-20 year equipment lifespan—and multiple simultaneous component failures, advised customer that repair costs would be substantial with limited long-term reliability. Discussed that even with component replacement, additional failures are likely imminen
Replaced malfunctioning Honeywell ZD20X8TZ zone damper serving the basement area. Installed new damper unit, verified proper mounting and wiring connections, and tested full open/close operation to confirm system functionality.
Completed routine cooling maintenance on a 22-year-old R22 air conditioning system. Obtained equipment documentation photos of make, model, and serial number information. Testing revealed the dual capacitor was operating outside manufacturer specifications, which was replaced to restore proper system operation. Comfort advisor was scheduled due to the age of the unit and R22 refrigerant type.
Responded to no cooling complaint on 3-year-old air conditioning system. Found debris lodged in contactor preventing proper electrical contact. Removed debris from contactor assembly, verified all electrical connections, and tested system operation. Unit restored to normal cooling function with contactor making proper contact and compressor running as designed.
Responded to no cooling complaint on Gibson condensing unit at residential property. Upon arrival, discovered no high voltage power to outdoor condenser. Found circuit breaker in off position and attempted to restore power by resetting breaker multiple times, but unit failed to receive power. Confirmed electrical fault preventing power delivery to condensing unit. Left disconnect switch in off position for safety until electrical issues can be resolved. Coordinated with electrician for follow-up service to diagnose breaker failure and evaluate existing knob and tube wiring that requires replacement. Unit remains non-operational pending electrical repairs to restore proper power supply to condensing unit.
Responded to warranty call for 12-5 Mitsubishi mini split system installed two months prior with water leaking from indoor unit on east side of home. Inspected system and traced issue to improper condensate drainage at outdoor unit. Found condensate line had improper pitch with upward curve causing water backup. Cut back approximately one foot of exterior condensate line to establish proper downward slope for gravity drainage. System drained accumulated water for approximately one minute and indoor unit leak resolved. Verified proper drainage operation and system returned to normal function.
Responded to no hot water complaint affecting entire home. Upon inspection of Richmond brand tanked water heater, determined unit had no electrical power supply. Verified water heater installation with proper copper piping connections and seismic restraint strapping in place. Advised customer that electrical issue requires licensed electrician to diagnose and restore power to unit before water heater can operate.
Responded to no cooling complaint on 9-year-old system at rental property. Upon arrival, found thermostat control wire completely severed at exterior penetration. Repaired wire by splicing and reconnecting to restore communication between thermostat and outdoor unit. Once system was operational, performed diagnostic testing with manifold gauges and confirmed system was operating with low refrigerant charge. System utilizes R-22 refrigerant. Coordinated with property owner to schedule service advisor appointment to discuss options for refrigerant recharge or further system evaluation. System left in safe operating condition pending owner decision on refrigerant service.
Responded to no hot water call on electric American Polaris water heater system with integrated air coil assembly. Upon inspection, discovered significant leaking from the air coil unit mounted on top of the water heater, with visible moisture and condensation present on connected piping. Confirmed complete loss of hot water functionality. Documented system configuration including all plumbing connections, ductwork, and air handler components. Awaiting property management authorization and confirmation of replacement unit availability on-site before proceeding with repair or replacement recommendations.
Completed air conditioning tune-up on outdoor condensing unit. During inspection, found the capacitor reading out of specification and replaced it with a new unit. Performed coil cleaning, washed the exterior unit, and verified proper system operation upon completion.
Responded to service call for assistance with Rusco spin-down sediment filter maintenance on residential well water system. Upon arrival, determined homeowner had been rotating filter housing in incorrect direction, resulting in overtightening rather than removal. Successfully loosened filter housing and demonstrated proper removal technique and rotation direction for future maintenance. Removed and inspected internal stainless steel screen element, showing homeowner correct cleaning procedure for sediment removal. Filter housing and screen were in good condition with no damage from overtightening. Reassembled unit properly and verified system operation with no leaks. Provided instruction on routine maintenance intervals and proper disassembly/reassembly procedures to ensure homeowner can independently perform future filter cleaning.
Responded to customer complaint of high-pitched, steady whistling noise occurring when air conditioning system activated and during operation. Upon inspection of Lennox furnace system, identified improperly seated air filter as source of noise. Repositioned filter to proper seated position within filter rack, eliminating air bypass and resolving whistling noise completely.
Responded to no-cooling complaint on 30-year-old air conditioning unit. Upon inspection, found compressor not operating due to failed capacitor leaking oil and rodent-damaged wiring. Repaired chewed wire and replaced defective capacitor. System restarted with outdoor fan operating, but compressor experienced delayed startup, indicating impending compressor failure. Advised customer that compressor is deteriorating and recommended obtaining replacement pricing due to age of unit and declining compressor performance.
Responded to repeat no-water issue at residence with well system. Verified electrical power supply to home was functioning properly. Based on recurring nature of problem and previous service call where tripped breaker was identified, recommended homeowner contact licensed well service company for comprehensive system evaluation and repair, as issue appears to be related to well pump or well-specific components beyond scope of general plumbing service.
Responded to a water heater leak at a residential property. Upon inspection, identified a 45-gallon natural gas power vent water heater, over 10 years old, actively leaking from the top connections. Determined the unit required full replacement due to age and extent of deterioration. Documented the existing A.O. Smith power vent installation with photographs showing the leaking connections, power vent motor assembly, copper supply lines, and overall system configuration. Provided replacement options for both 40-gallon and 50-gallon natural gas power vent units suitable for the existing installation location and venting requirements. Awaiting customer decision on replacement sizing and scheduling.
Responded to no cooling complaint on 10+ year old residential air conditioning system. Upon inspection of outdoor condensing unit, discovered one leg of power supply to contactor had melted and burnt off due to loose connection. Diagnosed failed contactor with burnt wiring requiring replacement. Documented findings with photos and contacted homeowner with repair recommendations. Customer declined service at this time to research options. Unit remains non-operational pending contactor and wiring repair.
Responded to no cooling complaint on 10+ year old R22 air conditioning system that had previously frozen up. Upon arrival, system had been off and evaporator coil was fully thawed. Performed diagnostic testing using refrigerant manifold and gauges, which revealed system was significantly low on R22 refrigerant charge. Measured operating pressures and temperatures on both low and high side of system. Low refrigerant charge was determined to be primary cause of freezing and loss of cooling capacity. Added R22 refrigerant to bring system back to proper operating charge levels. Verified proper system operation with corrected pressures and temperatures after recharge. System restored to normal cooling operation.
Responded to no cooling complaint on 2021 Amana air conditioning system with condenser fan running but no interior cooling. Diagnostic testing revealed failed dual run capacitor rated 40/5 µF—compressor section measured 0 µF while fan section read 5 µF. Replaced defective capacitor with new 40/5 µF unit, restarted system, and verified proper operation with 20°F supply/return temperature split after ten minutes of runtime. System restored to normal cooling operation.
Removed and replaced existing toilet with customer-provided fixture in commercial restroom facility. Installation included proper seating, wax ring replacement, water supply connection, and verification of proper flush operation and seal integrity.