Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in August 2026.
The most recent job was on August 26, 2026.
Performed comprehensive residential plumbing inspection including evaluation of all plumbing fixtures, drains, water supply piping, pumps, water heaters, and valves. Conducted complimentary water quality analysis as part of standard inspection protocol. Following inspection completion, restored water supply to the system and performed thorough leak detection testing with negative results confirmed. All components inspected were found to be functioning properly with no active leaks detected upon system restoration.
Completed seasonal AC tune-up and identified low subcool readings indicating potential refrigerant leak. Replaced failed hermetic compressor capacitor which was reading below specification. System restored to cooling operation; provided estimate for comprehensive leak detection and repair services to address underlying refrigerant loss issue.
Responded to service call for non-functioning garbage disposal in kitchen. Upon inspection, determined disposal unit was inoperable and required replacement. Removed existing garbage disposal and installed new sink basket assembly in white double-basin kitchen sink with granite countertop. Verified proper drainage and tested all connections for leaks. Completed installation of disposal flange and strainer assemblies in both basins, ensuring secure mounting and proper seal. All fixtures left in working order with no drainage issues detected.
Conducted initial assessment of three furnace and three air conditioning units to document equipment specifications and system configuration. Identified one non-functional air conditioning unit and one furnace with compromised heat exchanger requiring red tag. Scheduled comfort advisor consultation for equipment replacement recommendations and rescheduled comprehensive maintenance tune-ups for operational units.
Completed comprehensive AC tune-up on split system with furnace experiencing low airflow code. Replaced air filter, cleared condensate drain line, and performed condenser coil cleaning. Diagnosed and resolved excessive noise issue by tightening loose fan motor mounting screws at outdoor unit. Identified undersized return air duct as cause of low airflow code; current return requires upgrade to minimum 20x25 dimensions to meet system requirements. All components tested and operating properly; follow-up visit needed to increase return air duct size for optimal system performance.
Responded to water leak issue involving two outdoor hose bibbs. Upon inspection, identified a pinhole leak in secondary pipe connected to first outdoor spigot and complete lack of water flow from second spigot. Assessed both hose bibb installations, documented conditions with photographs showing exterior mounting locations and underlying plumbing configuration in crawl space area. Provided estimate for hose bibb replacement on both affected fixtures to resolve leaking and non-functional units.
Performed furnace tune-up on system over 10 years old that had frozen up the previous week and was actively leaking water from the bottom. Diagnosed A-coil heavily plugged with dust and debris, which caused the system to freeze and subsequently leak condensation water. Thoroughly cleaned the A-coil to restore proper airflow and prevent future freeze-ups.
Responded to service call for multiple plumbing issues including broken garbage disposal causing kitchen sink backup, malfunctioning shower cartridge resulting in hot water temperature control problems, and failed toilet components. Cleared kitchen sink drain line to restore proper drainage. Replaced defective shower cartridge with new unit to restore proper hot water temperature control and mixing valve function. Installed new fill valve assembly in toilet tank to address water flow issues and replaced toilet seat. All fixtures tested and verified operational upon completion.
Installed customer-supplied double-basin stainless steel kitchen sink with brushed nickel single-handle pull-down faucet in granite countertop. Additionally installed hot water recirculation pump system with PVC supply and return lines, pressure switch, isolation valves, and electrical connections in under-sink cabinet area to provide instant hot water delivery and reduce water waste.
Performed comprehensive air conditioning tune-up including system operational testing, condensate drain clearing, air filter inspection, and blower compartment evaluation. Performed condenser coil cleaning, verified system pressures and temperatures, confirming all parameters within manufacturer specifications. Customer enrolled in basic maintenance plan following service completion.
Responded to no cooling complaint on an 8-year-old residential air conditioning system. Upon arrival, found the outdoor condenser unit humming but not operating properly with warm copper lines and air blowing from the top of the unit. Diagnosed a failed capacitor preventing proper compressor operation. Verified air filter was clean and condensate drain line was clear. Replaced the defective capacitor and performed condenser coil cleaning to remove accumulated debris. Started the system and verified proper operation with refrigerant pressure testing, measuring approximately 8.5 degrees subcooling which falls within acceptable parameters. Confirmed thermostat communication with equipment and verified adequate airflow from indoor unit. System restored to normal cooling operation.
Responded to water leak in unfinished basement originating from kitchen sink branch line during dishwasher drainage. Upon arrival, discovered kitchen drain backing up and overflowing through the water softener standpipe, causing significant water accumulation on basement floor. Diagnosed the issue as a blocked drain line rather than a venting problem. Performed mechanical snaking of the kitchen drain line to clear the obstruction and restore proper drainage flow. Verified all fixtures were draining correctly and confirmed no further backup was occurring through the softener standpipe. Water main shutoff was not required during repairs, allowing household water service to remain operational throughout the procedure.
Responded to return visit for leak under kitchen sink. Upon inspection, identified loose slip nut on continuous waste assembly causing dripping. Tightened all slip nuts on drain connections and verified proper seal. Ran water through both sink drains to test system and confirmed leak was resolved with no further dripping observed.
Completed comprehensive air conditioning preventive maintenance tune-up on residential outdoor condenser unit. Performed standard seasonal maintenance procedures including system inspection, cleaning, and operational testing as documented on tune-up checklist. Unit operating normally with no deficiencies identified at time of service.
Completed routine heating tune-up on 5-year-old Lennox furnace system as part of scheduled maintenance agreement. Performed comprehensive inspection of furnace components including blower motor, gas valves, control mechanisms, and electrical connections with all systems found to be operating within normal parameters. No issues identified during service visit.
Completed comprehensive AC tune-up on 2-year-old Lennox system per customer concern that air doesn't feel as cold as expected. Performed full maintenance inspection on outdoor condenser unit, which showed significant dirt and debris accumulation on exterior surfaces, louvers, and coils from extended outdoor exposure. Thoroughly cleaned condenser coils and exterior components to restore proper airflow and heat transfer efficiency. Inspected indoor furnace unit and associated ductwork in mechanical room, verified all connections and venting systems. Tested system operation and confirmed unit is now functioning properly with improved cooling performance following cleaning and maintenance procedures.
Completed comprehensive tune-up and maintenance on both air conditioning and furnace systems. Performed electrical testing on both units, confirmed proper operation of all components, and pressure-washed the outdoor Trane condensing unit to remove debris and ensure optimal airflow through the coil fins. Documented equipment information with photographs of model numbers, serial numbers, and manufacturer labels for service records, as unit ages were previously unknown.
Responded to no cooling complaint on 10-year-old Carrier AC system. Found outdoor unit fan operating but compressor not running. Diagnosed failed dual run capacitor with low microfarad reading on compressor terminal. Replaced defective capacitor with proper OEM replacement, restoring compressor operation and normal cooling function immediately upon startup.
Responded to gas leak investigation at water heater location. Previous service provider had identified potential leak at gas valve and branch line. Replaced defective gas shutoff valve serving the water heater with new unit. Performed comprehensive leak testing on all gas connections and piping throughout the system. No additional leaks detected during thorough inspection and testing procedures. All gas connections secured and verified safe for operation.
Responded to service call for low water pressure issue on well system. Upon inspection, diagnosed faulty pressure switch as the cause of inadequate water pressure. Replaced defective pressure switch with new unit, restored proper electrical connections to terminal block, and verified system operation. Photographed completed installation showing new pressure switch mounted to pressure tank with proper wiring connections and plumbing components.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.