Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in August 2026.
The most recent job was on August 31, 2026.
Responded to call for water leak underneath kitchen sink. Upon inspection, identified failed basket strainer assembly as source of leak. Given the age of the home (built in 1987) and appearance of original plumbing components, the existing basket strainer had deteriorated beyond serviceable condition. Removed old basket strainer assembly, cleaned mounting surface and sink drain opening, and installed new basket strainer with proper sealing gasket and compression fittings. Verified all connections were secure and tested system under full water pressure to confirm leak was eliminated. Existing P-trap and drain assembly remained functional and were left in place.
Responded to low water pressure complaint affecting multiple fixtures following recent water treatment system installation. Diagnosed plugged iron filter cartridge (RFFE20-BB) as cause of reduced flow throughout plumbing system. Replaced defective iron filter cartridge under warranty, restoring proper water pressure and flow to all fixtures.
Completed comprehensive tune-up of residential furnace and air conditioning system, verifying temperature splits were within acceptable ranges for both units. Cleaned flame sensor to ensure optimal combustion, confirmed gas pressures met manufacturer specifications at high and low settings, verified all electrical connections were secure, and cleaned excessively dirty outdoor condenser unit to restore proper airflow and efficiency. Inspected UV light air purification system per customer request and identified burnt bulb requiring replacement, provided quote for bulb replacement, and confirmed both HVAC systems operating in good working condition following service.
Upgraded existing gas line to 1" diameter to meet generator requirements. Removed and replaced gas line running to generator unit, ensuring proper sizing and code compliance. Straightened and resized flex connector for improved gas flow and safety. All connections tested and verified for proper operation.
Completed annual air conditioning tuneup on 15-year-old Bryant system. Performed comprehensive maintenance including testing system operation, inspecting secondary heat exchanger, removing mice from blower compartment, testing blower capacitor, clearing condensate drain, and washing condenser coil. Found both compressor and blower capacitors reading slightly below specification and provided replacement pricing. Additionally provided pricing for inducer motor replacement due to previous noise concerns reported during winter operation, though unit currently operating quietly.
Responded to a water leak under the bathroom sink in a main level half bath. Upon inspection, determined the existing supply lines were compromised and required replacement. Ran new PEX water supply lines into the cabinet, installed new shut-off valves and supply lines to the fixture. Pressure tested all connections and verified no leaks were present upon completion.
Responded to service call for IBC gas boiler experiencing frequent shutdowns and operational issues since installation. Performed comprehensive maintenance on both boiler and furnace systems. Removed burner assembly and thoroughly cleaned gas boiler heat exchanger, flushing with water and vacuuming out accumulated debris. Cleaned condensate system to ensure proper drainage. Verified gas pressure at 8.4 inches water column, which is within acceptable range. Cleaned burner assembly and reassembled unit for startup testing. Inspected gas furnace which had previously displayed high heat limit codes. Cleaned flame sensor to restore proper flame detection. Checked heat exchanger condition and verified heat operation, limiting run time due to 90-degree ambient temperature. Identified airflow restriction issue caused by oversized MERV 12 filter on undersized 16x20 return. Recommended downgrading to MERV 7 or 8 filter to improve airflow and reduce strain on equipment, which may have contribute
Responded to a clogged toilet in a residential bathroom. Upon inspection, determined the blockage was caused by an accumulation of toilet paper in the drain line. Successfully cleared the obstruction using a closet auger, restoring full drainage function within approximately ten seconds. Tested the toilet to verify proper flushing operation and confirmed complete resolution of the issue.
Responded to kitchen sink drainage issue with leak under cabinet. Upon inspection, identified that the extension tube connected to the garbage disposal discharge arm was insufficient in length, creating an improper seal and allowing water to leak into the cabinet below. Removed the defective extension tube and installed a properly sized replacement to establish a secure, watertight connection between the disposal and drain assembly. Verified all connections for proper seal and tested system operation to confirm resolution of leak.
Responded to no cooling call on 1999 HVAC system where unit was running but not producing cold air. Upon arrival, found suction line completely frozen from compressor to evaporator coil, indicating restricted airflow or low refrigerant charge. Documented system condition with photos and confirmed system age exceeds 20 years, making repair cost-prohibitive. Coordinated with comfort advisor to schedule consultation regarding replacement options due to age and condition of equipment.
Completed phone follow-up regarding basement shower leak discovered after system was charged during previous service visit. Homeowner reported the shower line may not have been open during initial system charging, resulting in undetected leak. Scheduled plumbing department consultation for leak assessment and provided information about whole house plumbing remodel estimate availability.
Responded to gas leak complaint at water heater following previous service calls and utility company inspection. Performed comprehensive leak detection testing and confirmed active gas leak at the gas control valve connection point and suspected secondary leak at burner assembly interface. Utility company had previously identified leaking control valve on supply pipe requiring replacement. Unit showed signs of multiple repair attempts with recently replaced gas valve still exhibiting leak issues. Conducted thorough safety inspection of all gas connections, supply piping, and combustion components. Documented leak locations with photographic evidence showing water heater installation, gas valve assembly, and associated electrical safety controls. Recommended immediate repair or replacement of faulty gas control valve and burner assembly to eliminate hazardous gas leak condition and restore safe operation.
Completed comprehensive maintenance agreement service including both furnace and air conditioning system tune-ups. Performed thorough furnace inspection including heat exchanger examination, burner inspection, flame sensor cleaning, and condensate drain verification. Air filter was found clean and blower speeds were checked. Gas pressure was confirmed at proper levels and system startup achieved 50° temperature rise, indicating proper operation. Proceeded to air conditioning system where electrical components were inspected and capacitor was found slightly weak but still functional. Condenser coils were rinsed and cleaned thoroughly. Evaporator drain was checked and confirmed clear. System startup achieved 18° temperature drop, confirming adequate cooling performance. Provided estimate for capacitor replacement and recommended consideration of full system replacement given age of equipment rather than continued repairs of individual components. All systems operational at completion of
Responded to service call for air exchanger blowing heat and tripped system. Upon arrival, air exchanger and all AC units were operating normally. Performed roof inspection and testing of air exchanger with satisfactory results. Discovered severely plugged air filters restricting airflow and loud squealing noise from blower motor assembly. Investigation revealed worn blower motor shaft bushings causing excessive shaft play and potentially worn belt contributing to noise. Cleaned filters to restore proper airflow and verified system operation. Submitted request for pricing on replacement bushings and belt for permanent repair.
Responded to service call and performed comprehensive main sewer line inspection using camera equipment. Thoroughly inspected the entire main sewer line from cleanout to connection point at the main, finding no blockages, damage, or defects present in the system.
Completed comprehensive maintenance on Bryant HVAC system including both furnace and air conditioning unit. Performed furnace inspection including cleaning flame sensor, verifying condensate drainage, inspecting heat exchanger for integrity, and cleaning burners. Replaced completely plugged 20x25x1 furnace filter and AprilAire humidifier filter. Checked blower wheel operation and confirmed proper furnace operation with 45° temperature rise upon startup. Conducted air conditioning maintenance including electrical component inspection, condenser coil cleaning, and system startup verification with 18° temperature drop. All systems operating within normal parameters.
Replaced deteriorated toilet flange and built up the flange to proper height to ensure secure mounting on the tile floor. Reset toilet with new wax ring seal, verified proper alignment and stability, and confirmed leak-free operation of the fixture.
Completed comprehensive furnace and air conditioning tune-up on Daikin HVAC system. Performed full furnace inspection including heat exchanger, burners, and induced draft assembly—all components operating within specifications. Cleaned flame sensor, cleared condensate drain line, and blew out pressure switch hoses to ensure proper drainage and safety switch operation. Verified gas pressure settings and confirmed blower wheel condition. System startup demonstrated proper operation with 65° temperature rise across heat exchanger. During furnace inspection, identified deteriorated seal between collector box and inducer motor causing minor combustion gas leak. Prepared estimate for collector box replacement to address this safety concern. Proceeded to air conditioning maintenance, inspecting all electrical components and connections for proper operation. Flushed condenser coil to remove debris and restore optimal heat transfer efficiency. System startup confirmed proper cooling operation
Completed routine maintenance tune-up on five-year-old Lennox condensing unit. Replaced air filter after removing side access door, performed thorough inspection of outdoor unit including control boards and electrical components, and verified system cleanliness and operational efficiency. Advised discontinuing use of outdoor cover to optimize airflow and system performance, confirmed unit operating within normal parameters.
Replaced failing well pressure tank with new 44-gallon unit to restore proper water flow and prevent pump motor burnout. Removed old tank, installed new blue pressure tank utilizing existing tee assembly, and installed new pressure switch with brass fittings and connection hoses. System tested and operational upon completion.