Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in December 2025.
The most recent job was on December 8, 2025.
Installed new frost-free hose bibb utilizing existing connections and cut a 14"x14" access panel in ceiling to facilitate repair. Access panel was properly sealed and finished to match surrounding ceiling texture after completing installation.
Responded to service call for furnace requiring frequent reset. Found tripped rollout switch on south side unit causing heating failure. Upon startup, observed unstable flames when blower activated. Inspection revealed multiple cracked heat exchanger tube seams, confirmed by photo documentation. Advised customer on need for heat exchanger replacement or complete unit replacement. Customer preferred to obtain quotes for new unit installation due to age of existing equipment.
Performed scheduled tune-up on 10-year-old Daikin furnace which was operational but leaking water. Diagnosed worn inducer gasket causing the leak and applied high-temperature silicone as temporary seal until replacement gasket can be installed. Customer noted occasional hose plugging issues which was also inspected during service.
Responded to service call for Bradford White water heater exhibiting temperature regulation issues. Inspected unit and found thermal relief valve had activated twice in past month, though system was functioning normally during visit. Suspected faulty gas valve and advised customer to document error code if issue recurs for warranty replacement. Unit is approximately 2 years old with properly installed expansion tank and plumbing connections.
Responded to no-heat call at office location. System was found in lockout with pressure switch failed closed (code 23). Removed pressure switch tubing which allowed unit to fire up, indicating faulty pressure switch. After multiple cycles, system operated properly. Water staining observed on ceiling tile near system access panel. Will return to replace pressure switch after checking warranty status and schedule preventative maintenance service as requested by customer.
Responded to service call for Navien boiler displaying error code E13. Diagnostic testing revealed internal circulation pump failure due to faulty control board not outputting required 120V to pump. Adjusted dampers in the chiropractic section to address overheating issues. Submitted parts request for replacement control board, noting potential availability concerns due to unit age. Customer informed that new boiler installation may be necessary if parts are unavailable.
Diagnosed and resolved no-heat issue on 2-year-old furnace in mobile home. Investigation revealed furnace repeatedly clicking but failing to ignite due to a failed blower motor. Removed accumulated dust and debris from system and replaced the defective blower motor, restoring normal heating operation.
Successfully installed customer-supplied kitchen faucet in stainless steel sink mounted in dark granite countertop. Completed installation without modifications to existing configuration, maintaining original holes, supply lines, and stops.
Performed annual plumbing inspection of the property, examining bathroom fixtures and under-sink plumbing components. Evaluated supply lines, shut-off valves, P-trap assembly, and drainage system for functionality. Identified several issues requiring attention and provided customer with a detailed estimate for recommended repairs.
Responded to service call for Bryant 80% furnace (circa 2001) exhibiting intermittent operation failures. Diagnostic inspection revealed a crack in the high limit switch, causing system to randomly shut down before reaching thermostat temperature. Equipment was tagged as unsafe for operation and a comfort advisor was scheduled for replacement consultation.
Diagnosed furnace heating failure caused by water infiltration through fresh air intake venting. Ice dam on roof created condensation and water intrusion at intake pipe joints. Capped off compromised fresh air intake to prevent further water damage and restored system operation by redirecting air supply from interior space.
Conducted annual plumbing inspection with special attention to client's water softener system. Examined toilet components and interior tank mechanism for proper function. Inspected A.O. Smith water heater and water filtration system, verifying all connections and components were in good working condition. Performed requested water test as part of comprehensive evaluation.
Diagnosed no water flow issue in basement bathroom faucet. Determined cartridges were obstructed by debris despite adequate water supply to fixture. Presented options including warranty replacement, ordering new cartridges, or installing new faucet. Customer elected to replace with new two-handle widespread faucet.
Performed routine maintenance on 14-year-old Bryant Plus 95i furnace. Cleaned flame sensor and condensate trap which had significant buildup. Inspection revealed early signs of secondary heat exchanger deterioration, though no current compromise to system integrity. All electrical components tested within specifications, air filter and blower wheel were clean, and furnace is operating normally. Advised homeowner about secondary heat exchanger condition and recommendation to consider replacement in spring.
Performed annual furnace maintenance on 11-year-old high-efficiency system in condo unit. Completed standard tune-up procedures including cleaning flame sensor and filter replacement. Combustion analysis showed satisfactory efficiency readings (91.2%) with acceptable CO levels (17 ppm) and normal operating temperature (103.3°). System is currently functioning properly.
Installed customer-supplied thermostat with power adapter. Control panel wiring was properly connected with operational indicator lights confirmed. No warranty provided on customer's thermostat as agreed.
Diagnosed garage heater failure caused by faulty contactor preventing system startup. Inspected fan assembly and housing, noting heavy wear consistent with unit's age (10+ years). Customer was not on premises during service; accessed garage via provided code and documented findings with photos, but no repair was authorized.
Performed annual maintenance on 24-year-old FRP furnace. Adjusted gas train pressure from 3.94 inWC to 3.43 inWC, cleared debris and spider webs from condensate drain line and trap. Verified proper operation of inducer motor, capacitor, pressure switch, control board connections, and thermostat. Combustion CO measured at 5 ppm. Return air filter in moderate condition. System operating normally with no immediate concerns.
Responded to service call for kitchen sink drain issue where both sink bowls were experiencing slow drainage and backup. Diagnosed partial blockage in kitchen drain piping. Performed service by removing trap and thoroughly cleaning the affected drain piping using cable-style drain cleaner. Successfully restored proper drainage function, confirmed by flushing system and testing water flow.
Responded to service call for non-operational garbage disposal. Diagnosed unit as completely failed and replaced with new garbage disposal. Verified proper operation after installation and ensured no leaks from connections.
©2026 Hurlburt. All Rights Reserved.