with Purchase of Furnace & Air Conditioner
Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
We are also the go-to service provider for HVAC repair and installation in Hudson, Wisconsin. Our technicians are trained to work on all types of heating and cooling systems.
If your HVAC system isn’t working as it should, our specialists can provide prompt and effective furnace repair services and heating repair for homeowners in the Hudson, WI area.If your system is not able to be fixed, our professionals also offer reputable furnace installation services and will help you choose a system with the correct capacity for your house. Regardless of the issue, our skilled technicians will help restore the distribution of warm air in your living space.
It is highly recommended that you keep your HVAC and plumbing systems well-maintained and inspected often. Ensuring that your HVAC and plumbing systems receive the servicing they need will help prevent costly repairs, help your systems last longer, and help them withstand the severe winters.
We provide our customers with maintenance plan options as well as a 12-month 100% parts and labor warranty on repairs and replacements. As a member of our Hurlburt Family Rewards Club, you can save on repairs and energy costs in addition to receiving priority service.
At Hurlburt, we know how important it is to keep your system protected all year round. We are proud to offer residential, commercial, and emergency HVAC and plumbing services to cover all of your plumbing, heating, and cooling needs.
To find out more about getting our Hudson heating air and plumbing services, contact us today. If you would like to read about other customer’s experiences with us, we invite you to check out our reviews below!
There are many ways to find plumbers, including looking through magazine or newspaper ads, getting referrals from friends, and searching the internet for local plumbers in your area. But how do you know what kind of service you’re going to get before you hire them?Here are a few tips on how to find a good-quality plumber:
Make sure they’re certified. Read their reviews. Check to make sure they have many years of experience. AtHurlburt, we’ve been delivering high-quality services since 1959. Our friendly technicians strive to give you the best customer service possible so that no matter what you need, you feel satisfied with our work. If you’d like to learn more about the many services we offer, give us a call today!
Typically, most people will spend anywhere from $5,000-$10,000 on HVAC system replacement, with the average cost for replacement being about $7,000. This covers both the cost of the system and the cost of labor. However, some of the more high-end systems can get up to $20,000, so the replacement costs will vary depending on what kind of systems you purchase.Hurlburt offers unparalleled HVAC services. No matter what you need, we’ll work hard to ensure that we get the job done to your satisfaction. To find out more about our HVAC system replacement services, call us today!
The cost for HVAC repairs depends heavily on what system needs fixing and what the problem with it is. The average cost to have your AC systems repaired is about $320, with the average range being anywhere from $125-$450. For furnace repair, the average cost can fall anywhere from $130-$450, with most people paying around $250-$300. However, these numbers can be considerably lower or higher depending on the extent of damage to the unit and any parts that need replacing.At Hurlburt, we offer expert services and we are available to take your call 24/7. No matter when your HVAC systems have problems, we can help get them back up and running in no time. Call us for more information on how we can help you today!
Hurlburt in Hudson, WI provides a full range of electrical services aimed at keeping your home’s electrical systems functioning optimally and safely. Their offerings include precise electrical repairs for immediate concerns and the installation of whole-home generators to keep your power running smoothly during blackouts. The company’s technicians are committed to delivering excellent service and dependability. They also specialize in electrical panel services, essential for keeping your home’s electrical core in top condition, preventing hazards, and boosting electrical efficiency. Whether it involves updating your existing panel to support new appliances or just making sure your system is up to safety codes, Hurlburt‘s professionals offer reassurance with each service interaction.
Our professional team offers comprehensive electrical installation services that can significantly improve the comfort and functionality of your home. Their services include the installation of new lighting, which can completely alter the feel of your rooms, and the addition of more electrical outlets to support an increasing number of gadgets. Hurlburt also offers ceiling fan installations to maintain comfortable temperatures and enhance energy efficiency. They are committed to performing every job with a focus on safety and precision, ensuring reliable and seamless electrical solutions.
In Wisconsin, Hurlburt provides expert duct cleaning services that aim to improve both the performance of your air conditioning and the air quality within your home. Accumulated dust, allergens, and debris in ductwork can hinder airflow and decrease your HVAC system’s efficiency over time. Utilizing Hurlburt’s services can ensure that your air conditioning system functions at its best, which can reduce energy costs and extend the system’s lifespan. Moreover, the removal of these contaminants leads to better air quality, reducing respiratory irritants and promoting a healthier living space.
Completed comprehensive air conditioning tune-up and maintenance visit with no issues found. Performed full system operational testing, cleared condensate drain line, replaced air filter, and thoroughly cleaned outdoor condenser unit. Verified all refrigerant pressures and temperature readings, confirming system is operating within manufacturer specifications.
Completed routine air conditioning maintenance agreement visit with no reported issues. Performed comprehensive system inspection including operational testing, air filter replacement, blower capacitor testing, and condensate drain clearing. Cleaned condenser coil, verified all electrical components, and measured refrigerant pressures and temperatures, confirming all systems are operating within manufacturer specifications.
Responded to service call for excessive condenser noise and inadequate cooling in upper level of residence. Upon arrival, diagnosed noise issue originating from vibrating plastic condenser fan motor shroud rather than compressor assembly. Removed condenser top panel and installed foam tape between shroud and metal housing to eliminate vibration and noise. Verified significant noise reduction with homeowner approval. Performed system diagnostics and discovered refrigerant charge was below manufacturer specifications. Connected manifold gauges and confirmed low refrigerant levels contributing to insufficient cooling capacity in upper zones. Discussed findings with homeowner regarding ongoing performance concerns and necessity of refrigerant recharge to restore proper system operation and cooling efficiency. Documented system conditions and recommended corrective actions for proper refrigerant charge restoration.
Replaced two exterior hose bibs as requested by homeowner. Work required cutting access through interior wall to reach plumbing connections, then installing new frost-free sillcocks on exterior deck area. All connections were properly sealed and tested for leaks to ensure proper function.
Responded to water softener brine tank overflow issue at residential property. Upon arrival, system was functioning properly with no active leaking observed. Inspected and verified float mechanism and venturi were clean and operating correctly. Advised homeowner to drain remaining contaminated water and salt from brine tank and restart system with fresh materials, with follow-up recommended for water testing and potential iron filter installation evaluation.
Responded to no cooling complaint with uneven temperatures between upper and lower levels. Inspected air conditioning system and verified clean air filter. Examined supply trunk configuration off plenum for proper reducing fittings to ensure adequate airflow distribution throughout home. Measured total external static pressure at 0.5-0.6 inches water column, confirming acceptable range. Adjusted constant fan setting to 600 CFM and recommended homeowner utilize continuous fan operation to improve air circulation and temperature balance between floors. Performed outdoor unit diagnostics and refrigerant charge analysis. Connected manifold gauges and measured subcooling at approximately 2°F, indicating system is undercharged. Reviewed equipment data plate specifications for proper refrigerant charge requirements. Recorded ambient temperature at outdoor unit at 80.6°F. Advised homeowner of low refrigerant charge condition requiring additional refrigerant to restore proper cooling capacity.
Responded to service call for dripping exterior hose bib mounted on brick wall. Upon inspection, identified failed Mansfield brand anti-siphon frost-free spigot with turquoise corrosion visible on valve body. Customer had previously attempted washer replacement without success. Diagnosed faulty internal stem assembly requiring replacement. Ordered manufacturer-specific stem parts for proper repair of this 1999-era installation.
Responded to service call for malfunctioning outdoor faucet. Upon inspection, determined existing spigot was broken and required full replacement. Successfully removed damaged spigot and installed new unit, restoring proper functionality to outdoor water access point.
Responded to no cooling complaint and found evaporator coil frozen due to critically low refrigerant charge. Allowed system to thaw completely before performing diagnostics. Recharged system with 4+ pounds of R-410A refrigerant to manufacturer specifications. Verified proper operation with 22° temperature split across evaporator coil. System restored to normal cooling operation. Advised monitoring for potential leak given significant refrigerant loss.
Completed annual Family Rewards cooling maintenance visit on Lennox air conditioning system. Performed comprehensive AC tune-up including thorough cleaning of all components, system inspection, and operational testing. Unit operating properly with no issues or deficiencies identified.
Responded to report of upstairs shower drain leak with water shut off to the house. Conducted thorough inspection of tub and drain assembly but was unable to locate any visible source of leaking. Performed water flow test through tub drain system with no leak detected during testing, suggesting issue may be intermittent or related to specific usage conditions.
Responded to no cooling complaint on 20+ year old R22 system experiencing coil freeze-up. Customer had unit off with fan running to allow thawing. Performed diagnostic inspection of blower assembly, air filter, and evaporator coils—all found clean with adequate airflow. Blower capacitor tested slightly below optimal rating but sufficient for full-speed operation. Connected manifold gauges to refrigerant circuit and identified low refrigerant charge as primary cause of freeze condition. Due to system age, R22 refrigerant type, and declining charge indicating potential leak, recommended customer consult with service advisor regarding repair versus replacement options given the obsolete refrigerant and system longevity considerations.
Responded to a toilet leak caused by a malfunctioning fill valve. Removed the toilet tank lid, diagnosed the faulty fill valve assembly, and replaced it with a new unit. Additionally addressed the broken shut-off valve to restore proper water control to the fixture.
Responded to no cooling complaint on system where maintenance was recently completed. Found outdoor unit not operating due to capacitor making contact with low voltage terminal, causing electrical short that damaged both outdoor unit controls and indoor thermostat. Remounted capacitor in proper position to prevent contact with electrical components, replaced damaged thermostat, verified system operation and proper cooling cycle. All repairs completed under warranty.
Responded to no cooling complaint on aging AC system. Upon inspection, discovered air filter completely clogged with white ultrasonic humidifier dust causing high-pitched whistling and excessive blower noise. Removed contaminated filter, which immediately eliminated whistling and reduced motor noise. Proceeded to outdoor unit and performed electrical diagnostics, finding capacitor testing weak and slightly out of specification but still functional. Cleaned condenser coil and cycled system for performance verification. Unit achieved proper cooling with 20° temperature split across coil. Installed temporary filter and provided estimate for capacitor replacement. System operational at time of departure, advised discontinuing use of ultrasonic humidifier to prevent future filter contamination and airflow restriction.
Responded to no cooling call on 20-year-old residential air conditioning system. Upon arrival, found condenser fan motor not operating while compressor was running. Diagnosed failed dual run capacitor preventing fan motor operation. Replaced defective capacitor and verified proper fan motor operation. Performed comprehensive maintenance service including condenser coil cleaning, condensate drain line clearing, and air filter inspection. Conducted system performance testing with refrigerant pressure measurements on suction line, confirming proper operating pressures and adequate temperature differential across evaporator coil. System restored to full cooling operation with no refrigerant leaks or freeze-up conditions detected. Documented equipment condition with photos showing corroded copper refrigerant lines and overall unit wear consistent with age. Advised customer of condenser fan motor condition for future consideration. Unit operating normally at departure.
Replaced heat exchanger on boiler under parts warranty coverage. Also replaced igniter electrode and electrode gasket. Following installation, conducted thorough test run to verify proper operation and inspected all connections for leaks. System tested successfully with no issues detected.
Responded to a clogged bathroom lavatory sink drain that was backing up during use. Diagnostic assessment confirmed the blockage was isolated to the lavatory sink drain line with no other fixtures affected. Cabled the drain line and successfully removed a significant accumulation of hair and sludge buildup causing the obstruction. Upon reassembly, discovered the existing tubular trap was leaking and required replacement. Installed a new tubular trap assembly under the lavatory sink to ensure proper seal and drainage. Conducted final testing to verify proper drain operation and confirmed no leaks were present at any connections.
Responded to emergency water leak at exterior hose bibb that was actively pouring water, requiring immediate shutdown of main water supply to the property. Removed failed outdoor spigot assembly and accessed copper supply line through foundation wall. Installed new frost-free hose bibb with proper seating and connection to existing copper piping, ensuring watertight seal at all connection points. Restored water service to property and verified no leaks at installation site upon pressurization.
Responded to a basement floor drain backup occurring when the washing machine discharged, causing water to overflow from the utility sink onto the floor with extremely slow drainage taking approximately two hours to clear. Upon arrival, verified the complaint and tested all toilets, confirming proper drainage throughout the home, which indicated the blockage was isolated to the floor drain line rather than the main sewer line. Cabled the floor drain line to clear the obstruction and successfully restored flow. Extracted a large accumulation of lint from the drain line, which was the primary cause of the blockage. Following the cable work, performed multiple flow tests by filling and emptying the laundry tub several times to ensure complete clearance and proper drainage function. The floor drain is now operating at normal capacity with no backup or slow drainage issues.