Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in December 2025.
The most recent job was on December 11, 2025.
Inspected water leak reported through ceiling. Cut access opening to investigate source, finding no active leakage after water was restored. Identified low boiler pressure (5 psi) as possible contributor; recharged system to 20 psi. Monitored for one hour with water restored to confirm resolution. Potential cause may be ice dam related; no ongoing leakage observed during service period.
Responded to no heat complaint on 15+ year old furnace producing burning odor and fan noise. Performed diagnostic inspection revealing failed heat exchanger with significant corrosion and discoloration as confirmed by camera inspection of interior chambers. Unit also exhibited motor failure. Presented replacement options to customer due to age of system and safety concerns.
Replaced leaking, unrepairable water heater with new 50-gallon A.O. Smith ProLine XE natural gas power vent unit. Installation included proper connection of gas line, water lines, and PVC venting components in utility area with suitable drainage.
Performed comprehensive boiler maintenance that included replacement of defective zone valve head, expansion tank with zero PSI pressure, and unresponsive boiler pressure gauge per customer's approval. During inspection, discovered water pressure irregularities when adding water, confirmed with secondary gauge testing. All components successfully replaced and tuneup completed; system now functioning properly with restored pressure regulation.
Completed routine furnace tune-up with comprehensive diagnostic testing including combustion analysis and gas pressure verification for both high and low stages. Inspected heat exchanger, flame sensor, burners, and blower components finding all in normal operating condition. Cleaned pressure switch and verified proper thermostat operation with satisfactory heating performance.
Responded to service call for loose reverse osmosis faucet previously installed in August. Inspection revealed the mounting nut on the underside of the faucet had loosened. Successfully tightened the nut to secure the faucet assembly.
Performed scheduled furnace tune-up on 12-year-old FRP system. Conducted diagnostic testing of gas valve assembly and electrical components using multimeter. All systems functioning normally with no issues identified.
Responded to customer complaint regarding excessive condensation on Venmar Constructo air exchanger. Inspection revealed broken bathroom motor clip and severely contaminated filter. Replacement of damaged components was completed to restore proper system function and reduce moisture buildup.
Successfully installed one 7.5 kW Qmark Hanging Garage Heater (25,000 BTU) in the garage, replacing the previous unit. System tested and operating correctly.
Performed routine maintenance on 10-year-old natural gas furnace including combustion analysis, heat exchanger inspection, and system cleaning. Identified elevated CO levels (79 ppm) during initial testing; cleaned flame sensor, heat exchanger, burners and orifices, resulting in improved CO readings (9 ppm). Verified proper operation of gas pressure, blower motor, pressure switch, and thermostat functionality with no immediate concerns identified.
Replaced broken drain assembly in bathroom sink where pivot rod retaining nut had failed, causing stopper operation issues. Removed damaged components and installed new drain assembly, restoring proper functionality of the sink drain stopper mechanism.
Performed annual tune-up on 11-year-old FRP furnace. Conducted comprehensive inspection including heat exchanger evaluation, combustion analysis test, gas pressure verification, and examination of flame sensor, burners, and blower components. System is operating normally with appropriate heating function; however, identified a cracked collector box requiring replacement. Recommended new air filter as current one is in moderate condition. Quote for collector box replacement sent to homeowner via email.
Performed diagnostic inspection on aged furnace experiencing cycling issues approximately every 15 minutes due to airflow restrictions. Interior inspection revealed significant debris accumulation in the compartment and potential issues with the blower motor assembly. Recommended system maintenance to address dirt buildup and discussed monthly maintenance package options with customer. Referred to comfort advisor for evaluation of replacement options given the unit's age and condition.
Responded to service call for non-functioning Aprilaire whole-home humidifier. Diagnostic testing revealed E1 error code indicating control board or humidity sensor issue. Upon inspection, discovered humidity sensor was heavily coated with dust, impeding proper function. Thoroughly cleaned sensor, reset unit, and performed operational test. Humidifier restored to proper working condition. Customer advised of potential need for control board replacement if issue recurs.
Performed comprehensive maintenance on 1-year-old FRP furnace. Completed full system inspection including heat exchanger examination, combustion analysis testing, gas pressure verification (high and low stage), and inspection of flame sensor, burners, and blower components. All components functioning normally with no immediate concerns identified. Cleaned pressure switch, checked thermostat operation, and replaced air filter. System is heating properly and operating within normal parameters.
Responded to service call for non-functioning boiler system exhibiting loud squealing noise. Diagnostic inspection revealed failed inducer motor and severely plugged heat exchanger. Visual inspection confirmed extensive frost accumulation on components and significant corrosion on pressure gauge assembly. Performed complete replacement of inducer motor and boiler unit to restore proper heating function.
Inspected boiler after CO detector activation prompted fire department response. Discovered a crack in boiler jacket beneath heat exchanger, causing carbon monoxide to be drawn into the home. Recommended complete boiler replacement and established temporary arrangements for customer pending installation of new equipment.
Diagnosed and restored operation of non-functioning natural gas water heater in basement for handicapped customer unable to access lower level. Additionally, tightened loose kitchen faucet and addressed toilet leak by installing new supply line and stop valve.
Performed diagnostic evaluation on 27-year-old Ruud furnace that had stopped working. Testing revealed multiple age-related issues including rust in cabinet, dirty blower wheel, high inducer amp draw (measured at 0.25A), and aging electrical components. Combustion analysis confirmed system is currently operating safely with 92.2% efficiency, 9.6% Oâ‚‚, and CO levels within acceptable range (9 ppm). Restored heat functionality but advised customer on replacement options for furnace, AC, and generator due to system's advanced age and deteriorating condition.
Performed comprehensive furnace tune-up on 10-15 year old system after customer reported delayed startup issues. Evaluated inducer motor and control board functionality; both components operating within normal parameters. Conducted carbon monoxide testing and verified proper gas pressure readings. Inspected insulated flexible ducting throughout the system, noting normal dust accumulation but no structural concerns. No immediate repairs needed.