Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in January 2026.
The most recent job was on January 15, 2026.
Inspected customer's water heater system and identified significant copper pipe corrosion at connection points, with visible verdigris formation indicating prolonged moisture exposure. Documented mold growth on mechanical room wall caused by inadequate ventilation in the small space. Recommended installation of a recirculating pump and implementation of improved ventilation solutions including a dehumidifier, fan, and proper pipe insulation to prevent further deterioration.
Completed scheduled furnace maintenance on a two-zone FRP system with four zone dampers. Performed comprehensive tune-up including testing operation, cleaning air filters, verifying gas pressure, inspecting routine components, and confirming proper drain flow. Conducted electrical testing with multimeter and inspected the air exchanger, noting customer recently replaced filters. Both upstairs and downstairs zones verified to be functioning correctly.
Responded to service call for boiler water leak. Identified condensate drain tube that had become disconnected from PVC drain pipe. Properly reinserted tube into drain, resolving the water leak issue. System now functioning normally with proper condensate drainage.
Performed comprehensive furnace tune-up, including cleaning flame sensor and verifying proper condensate drainage. Inspected heat exchanger which showed some rust spots but remains functionally sound. Investigated reported musty smell when blower operates but found no evidence of water in ductwork or other obvious causes. Homeowner was advised about possible connection between continuous blower operation and odor issue. Discussed options for whole-house humidifier and duct cleaning services.
Responded to warranty service call for lukewarm water in shower. Determined previous carpenter failed to adjust cartridge to appropriate temperature setting. Adjusted shower cartridge to hottest setting, resolving the temperature issue in the bathroom's modern glass-enclosed shower with matte black fixtures.
Diagnosed furnace lockout condition indicated by seven-flash code. Discovered backed-up condensate trap causing pressure switch blockage, which prevented furnace from maintaining operation. Cleaned condensate trap and verified proper drainage, then reassembled unit and confirmed normal operation with proper water flow.
Successfully replaced 2-stage gas valve on residential furnace. Verified absence of gas leaks after installation, set proper gas pressure, and confirmed system operation. Unit is now functioning correctly with no issues detected.
Replaced failed Tekmar 261 2-stage boiler control module for both boilers, reconnected wiring, and configured set points. Repaired gas leaks by replacing two unions at the gas supply connections. System operation verified with electrical testing and pressure checks; all components now functioning normally.
Performed comprehensive furnace tune-up on system less than one year old. Conducted operational testing including gas pressure verification, corrected backwards air filter installation, inspected humidifier and air exchanger, and cleaned routine components. Electrical testing with Fieldpiece meter confirmed proper amperage readings (0.23) across components, and condensate drain was flushed to ensure proper drainage. All systems functioning within normal parameters.
Responded to a water leak issue at a laundry tub sink. Upon inspection, determined the leak originated from loose drain piping connections beneath the tub. Performed necessary tightening of all drain components, successfully resolving the leak.
Performed comprehensive maintenance service on mini split system, including complete disassembly of the head unit. Thoroughly cleaned heavily soiled air filters, blower wheel, and internal components as documented in photos. System operation verified after reassembly with all functions testing normal.
Performed boiler tune-up service which included operational testing, igniter removal/inspection, and heat exchanger assessment. Found significant buildup in heat exchanger requiring cleaning, loose igniter causing exhaust gas leakage that melted surrounding insulation and ground wire. Secured broken screw holding igniter and noted missing gasket underneath igniter. Customer elected to proceed with igniter replacement but deferred heat exchanger cleaning.
Performed comprehensive furnace tune-up on 2-year-old unit. Inspected flame sensor, verified proper condensate drainage, checked air filter and blower wheel condition, and tested all electrical components. Confirmed proper gas pressure settings and verified normal system operation. Explained to homeowner the ambient heat notification on their thermostat relates to heat pump operation during cold weather conditions when the furnace serves as backup heat.
Inspected shower valve system where ball valve does not extend beyond tile surface. Identified need for replacement with a splitter valve. Examined existing tub/shower installation with recessed drain cover and spout. Provided estimate for bathroom completion work.
Diagnosed 20-year-old A.O. Smith 50-gallon electric water heater with active leak from tank bottom, evidenced by significant rust formation at base. Determined unit had reached end of serviceable life due to tank failure. Removed failed unit and installed new water heater with proper connections to existing plumbing system.
Performed comprehensive furnace tune-up on 10-year-old unit. Inspected heat exchanger, tested electrical components and verified proper system operation. Replaced humidifier pad, confirmed humidifier functionality, and verified clean air filter with temperature rise within specifications. All systems operating normally.
Successfully installed customer-supplied kitchen faucet in a double stainless steel sink mounted in beige granite/composite countertop. Completed installation of main chrome fixture with high arched neck and single lever handle, ensuring proper function and no leaks.
Responded to no heat call for a furnace installed 2 years ago. Diagnosed a code 311 on the furnace board related to airflow restriction. Determined the air filter was being clogged by mineral deposits from portable humidifiers. Advised customer to replace the filter and recommended alternative humidification methods to prevent recurrence of the issue.
Performed annual maintenance on aging furnace (10+ years). Completed comprehensive tune-up including operational testing, filter replacement, and condensate drain cleaning. Discovered active leak from collector box with visible corrosion and moisture accumulation. Heat exchanger appears intact and burners reasonably clean. Provided replacement options for the collector box and scheduled follow-up consultation regarding potential furnace replacement.
Responded to service call for recently installed heat pump displaying intermittent Error Code 125. Diagnosed recurring fault requiring power cycling to temporarily restore function. Inspected Lennox control board and reviewed error history. After consulting manufacturer documentation regarding the persistent E125 error, recommended replacement of furnace control board to resolve the system malfunction.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.