Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in January 2026.
The most recent job was on January 26, 2026.
Responded to service call for water heater with no hot water. Diagnosed pilot light failure and identified pinhole leak in tank. Provided customer with replacement options as repair not feasible due to tank integrity compromise.
Diagnosed 21-year-old Bryant furnace with failed heat exchanger causing short-cycling and immediate shutdown. System inspection revealed control board issuing 24V code during high-fire operation and noisy inducer motor. Unit was tagged out of service due to safety concerns, with recommendation for replacement of heat exchanger, control board, and draft motor.
Diagnosed non-functioning humidifier system during IAQ service call. Identified faulty solenoid valve that was receiving power and activating but failing to allow water flow to the humidifier. Provided assessment to homeowner and scheduled follow-up appointment to replace the solenoid valve as the correct replacement part was not available on-site.
Responded to service call for leak beneath kitchen sink. Upon inspection, discovered a small pinhole in the chrome P-trap due to corrosion, causing a minor drip. Discussed repair options with customer, including replacement of the affected section of piping, while noting customer's interest in potentially installing a new faucet and sink in the future.
Responded to call for garage heater not working properly. Diagnosed intermittent ignition issue with Reznor ceiling-mounted unit. Cleaned flame sensor which temporarily restored operation. Further inspection revealed burnt solder joint on control board where igniter wire connects, causing inconsistent electrical connection. Discussed findings with homeowner who preferred to pursue replacement options for the aging unit rather than repair. Unit was operational upon departure but will require either control board replacement or full system replacement for permanent resolution.
Responded to emergency call for flooded boiler room. Diagnosed burst pipe at hose bibb connection that had frozen and failed. Replaced damaged hose bibb and associated piping to restore system functionality and prevent further water damage.
Responded to a no-heat call for aging furnace exhibiting pressure switch error code. Diagnostic testing with Fluke 902FC meter revealed 47.3 ohms resistance. Found exhaust flue blocked with ice accumulation, cleared the obstruction, and removed water from pressure switch and condensate trap. System successfully restored to normal operation; recommended replacement of dual pressure switch due to water intrusion.
Diagnosed no-heat condition on natural gas furnace installed last year. Determined exhaust vent was frozen at roof termination. Temporarily rerouted furnace exhaust to fresh air intake pipe to restore heat operation. Will need to return with additional technician to safely access roof for proper vent clearing and restore normal venting configuration.
Inspected gas furnace with no heat complaint. Discovered significant deterioration and cracking in heat exchanger with visible rust and discoloration. Determined heat exchanger has failed, creating potential safety hazard. Recommended complete system replacement due to age of unit (approximately 8 years) and cost-effectiveness versus repair.
Responded to service call for 40-gallon natural gas water heater with pilot light failure and blue flashing indicator light. Diagnosed issue, successfully relit pilot light, and tested gas valve operation through temperature cycle to verify proper function. Provided preventative consultation regarding potential future pilot issues and replacement options for the 8-year-old unit.
Responded to no heat complaint on 2-year-old furnace where homeowner expressed concern about basement temperatures potentially freezing pipes. Upon inspection, determined basement temperature was 59°F, well above freezing threshold. After evaluating ductwork configuration and discussing options with customer, drilled a 1-inch hole in supply run to provide moderate warm airflow to basement without compromising overall system performance or creating excess duct noise.
Responded to no heat complaint on a 2-year-old furnace system that was tripping on pressure switch. Diagnosed issue as frozen condensate drain trap caused by cold air intake positioned adjacent to the trap. Temporarily replaced inducer motor for diagnostic purposes, which confirmed the source of high-pitch noise was not the inducer itself. Cleared and cleaned the frozen drain trap, which resolved the operational issues and restored proper system function.
Responded to follow-up service call for recently installed Weil-McLain boiler not maintaining adequate temperature. Diagnostic testing revealed water temperature was only reaching 170°F, insufficient for effective baseboard heating in poorly insulated residence. Adjusted boiler settings to increase water temperature to 190°F to compensate for heat loss and improve home comfort.
Responded to service call for boiler reporting no hot water and error code #5. Upon inspection, confirmed boiler was functioning properly with no stored error codes. Determined the "5" display was normal operation indicator when burner is active during in-floor heating cycle. Verified domestic hot water tank was at proper temperature and operating correctly. Inspected external vent to ensure no freezing obstruction. Explained normal system operation to customer who was unaware of display indicators during heating cycles.
Responded to no-heat complaint where customer reported temperature dropping from set point of 70°F to 65°F. Inspection revealed furnace was operational but with restricted airflow due to dirty filter. Replaced filter and advised customer that during extreme cold weather, maintaining a 3-degree temperature differential is normal performance and recommended not setting thermostat above 70°F under these conditions.
Replaced leaking 50-gallon natural gas water heater with a new 50-gallon PowerVent unit in basement utility area. Installation included connecting copper water lines and ensuring proper electrical connection to the service panel. Water heater is now operational with no signs of leakage.
Inspected four toilets reported as leaking. Diagnosed one toilet with a faulty fill valve causing continuous running. Removed corroded original fill valve showing significant mineral deposits and rust. Installed new fill valve assembly to restore proper tank filling operation and eliminate water waste.
Responded to no heat call for 17-year-old Nordyne high efficiency furnace. Diagnosed seized draft motor as the cause of system failure. Customer opted to consult with relative in HVAC industry regarding replacement options for draft motor or complete system.
Performed comprehensive furnace tune-up including cleaning flame sensor, verifying clear condensate drainage, and inspecting heat exchanger components. Confirmed clean air filter and tested all electrical components, which were operating within specifications. Noted slight wobble in blower wheel operation suggesting possible imbalance, but access limitations prevented further inspection. System is functioning properly with appropriate 60° temperature rise.
Replaced two corroded brass ball valves exhibiting pinhole leaks in the plumbing system. Leakage likely caused by high pH levels in water or excessive water velocity through PEX piping from recirculation pump. New valves installed within wooden framed structure with proper connections to existing PVC piping.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.