Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in May 2026.
The most recent job was on May 19, 2026.
Responded to leak at wall-hung sink in unit. Upon inspection, discovered loose packing nut on angle stop causing water seepage. Tightened packing nut and temporarily stopped the leak. Noted both angle stops under sink are severely corroded with extensive rust, mineral buildup, and deterioration, making shut-off valves difficult to operate. Due to advanced corrosion and inability of valves to turn properly, provided estimate for replacement of both angle stops to be scheduled when water can be shut down to entire property.
Completed scheduled air conditioning tune-up and preventative maintenance inspection per service agreement. System evaluated and found to be operating within normal parameters with no deficiencies noted. Replaced air filter and confirmed proper airflow throughout the unit.
Completed comprehensive plumbing inspection of residential property and successfully replaced defective flush valve assembly in basement powder bathroom toilet, restoring proper flushing operation. Documented existing plumbing fixtures throughout property, including kitchen faucet and sink installations, with photographic records for maintenance history.
Completed scheduled cooling system tune-up and maintenance on inverter-type air conditioning system with Amana furnace. Performed comprehensive inspection of outdoor unit control board and electrical components, verified proper operation of all circuits and connections. Cleaned condenser coils, cleared condensate drain line, and measured temperature differential across the system. All components operating within manufacturer specifications with good temperature drop achieved despite cooler ambient conditions. No deficiencies or concerns identified during inspection.
Diagnosed leaking lavatory drain in upstairs bathroom and identified linkage connection failure at sink stopper assembly. Assessed P-trap configuration and drain components beneath fixture, documented existing plumbing setup including PVC drainage system and supply line connections. Provided estimate for complete drain assembly replacement to resolve leak and restore proper stopper operation.
Completed 12-4 AC tune-up and maintenance on a 12-year-old system found to be functioning properly. Inspected and replaced air filter, verified system temperatures with digital thermometer showing 100°F reading at supply duct, and confirmed proper operation of hard start kit. All HVAC components operating within normal parameters.
Completed comprehensive AC tune-up on 4-year-old system. Performed full system inspection, checked electrical components including capacitor and contactor connections, verified proper operation of all controls, and tested system performance. Found dirty air filter during inspection; advised homeowner to replace immediately and recommended establishing regular filter replacement schedule and ongoing maintenance plan to ensure optimal system efficiency and longevity.
Completed scheduled maintenance tune-up on 13-year-old R410A air conditioning system. Replaced pitted contactor to ensure reliable operation. Documented equipment make, model, and serial numbers with photographs per service request. Comfort advisor scheduled to discuss system replacement options, as homeowner is considering full unit replacement due to previously identified cracked heat exchanger from winter service call.
Responded to backyard hose bibb experiencing leaks from both the vacuum breaker and packing nut. Removed the failed unit and installed a new Woodford hose bibb to restore proper function and eliminate all leaking.
Completed annual plumbing inspection of residential property with all systems found in good working condition. Identified defective Roman tub strainer and performed replacement to restore proper drainage function. Accessed plumbing infrastructure through ceiling access point to verify condition of PVC drain and vent lines, which showed normal aging but remained structurally sound.
Completed scheduled cooling system tune-up and maintenance inspection on residential HVAC system. Performed comprehensive evaluation of outdoor condenser unit and indoor furnace components, verified all operational parameters within normal ranges, and confirmed system is functioning properly. Recommended capacitor replacement as preventive maintenance to ensure continued reliable operation.
Completed annual AC maintenance tune-up on a 6-year-old Daikin system. The condenser coil had accumulated significant dust and debris buildup, which was thoroughly rinsed and cleaned to restore proper airflow and system efficiency. All system components were inspected and found to be operating within normal parameters with no additional issues identified.
Completed annual AC tune-up on one-year-old system under maintenance agreement. Performed comprehensive inspection of indoor and outdoor units, verified proper refrigerant charge and temperature split across evaporator coil, checked electrical connections at panel and disconnect, and confirmed all components operating within manufacturer specifications. System found clean and functioning properly with no issues identified.
Performed comprehensive preventive maintenance tune-up on an 8-year-old single-zone air conditioning system. Conducted thorough inspection of condenser unit including verification of electrical components, capacitor operation, and amperage draw—all found within normal operating parameters. Measured temperature splits across evaporator coil confirming proper refrigerant charge and cooling performance. Inspected air filter at indoor unit, which was clean and properly installed. Verified outdoor condenser coil cleanliness and adequate airflow. All electrical connections tested and confirmed secure with no signs of overheating or wear. System operating efficiently with no deficiencies noted upon completion of service.
Completed comprehensive AC tune-up on 10-year-old system with no prior known issues. Performed full system operational testing, verified air filter condition (clean), cleared condensate drain line, and tested blower capacitor (reading within normal parameters). Cleaned condenser coil, inspected all outdoor components including compressor, fan motor, and electrical connections. Measured system performance with temperature split of approximately 19°F across evaporator coil, confirming optimal cooling efficiency. All components operating within manufacturer specifications with no deficiencies noted.
Responded to a water leak at an exterior hose bibb where water was leaking from the handle during operation. Replaced the faulty stem assembly with new parts to restore proper function. Tested the fixture after installation to verify the leak was eliminated and the hose bibb operates correctly without further water loss.
Completed comprehensive air conditioning tune-up and system inspection as part of preventative maintenance agreement. All system components operating within normal parameters; however, testing revealed outdoor unit capacitor has fallen out of manufacturer specifications and will require replacement in near future to prevent potential compressor failure. Customer declined capacitor replacement at this time due to budget constraints but was informed of the recommendation for future service.
Completed comprehensive AC tune-up on system consisting of newer Day and Night furnace and older Tempstar air conditioning unit utilizing R22 refrigerant. Replaced air filter, cleared condensate drain line, and performed exterior condenser coil cleaning. Discovered and removed mouse nest from service panel compartment and repaired chewed wiring with electrical tape. System startup confirmed proper operation with return air temperature at 62°F and supply air at 45°F, delivering approximately 17° temperature split. Suction line verified cold to touch during operation. Unable to obtain refrigerant pressure readings due to backward-facing service port positioning against sheet metal obstruction. Observed minor rodent contamination on contactor; unit remains fully operational. Provided replacement contactor pricing for future consideration. Advised property owner that R22 refrigerant service is being phased out and system replacement will be required when unit fails. Documentation photos ca
Completed annual AC tune-up on residential Lennox HVAC system and verified unit operating within normal parameters. Identified compressor operational noise concern related to neighbor complaints, determined noise level to be within manufacturer specifications but audible in proximity. Installed insulated compressor jacket to suppress operational noise and minimize sound transmission to surrounding properties.
Performed annual air conditioning maintenance tune-up on 15-year-old Bryant system. System was found to be low on refrigerant charge despite having refrigerant and dye added during previous service visit last year. Conducted leak detection inspection and identified active refrigerant leak at the A-Coil, evidenced by UV dye tracing from prior service. Documented system condition with photographs showing furnace unit and coil contamination. Advised customer that A-Coil replacement or full system replacement is required to restore proper operation and prevent continued refrigerant loss.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.