Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in May 2026.
The most recent job was on May 29, 2026.
Responded to water softener brine tank overflow issue at residential property. Upon arrival, system was functioning properly with no active leaking observed. Inspected and verified float mechanism and venturi were clean and operating correctly. Advised homeowner to drain remaining contaminated water and salt from brine tank and restart system with fresh materials, with follow-up recommended for water testing and potential iron filter installation evaluation.
Responded to no cooling complaint with uneven temperatures between upper and lower levels. Inspected air conditioning system and verified clean air filter. Examined supply trunk configuration off plenum for proper reducing fittings to ensure adequate airflow distribution throughout home. Measured total external static pressure at 0.5-0.6 inches water column, confirming acceptable range. Adjusted constant fan setting to 600 CFM and recommended homeowner utilize continuous fan operation to improve air circulation and temperature balance between floors. Performed outdoor unit diagnostics and refrigerant charge analysis. Connected manifold gauges and measured subcooling at approximately 2°F, indicating system is undercharged. Reviewed equipment data plate specifications for proper refrigerant charge requirements. Recorded ambient temperature at outdoor unit at 80.6°F. Advised homeowner of low refrigerant charge condition requiring additional refrigerant to restore proper cooling capacity.
Responded to service call for dripping exterior hose bib mounted on brick wall. Upon inspection, identified failed Mansfield brand anti-siphon frost-free spigot with turquoise corrosion visible on valve body. Customer had previously attempted washer replacement without success. Diagnosed faulty internal stem assembly requiring replacement. Ordered manufacturer-specific stem parts for proper repair of this 1999-era installation.
Responded to service call for malfunctioning outdoor faucet. Upon inspection, determined existing spigot was broken and required full replacement. Successfully removed damaged spigot and installed new unit, restoring proper functionality to outdoor water access point.
Responded to no cooling complaint and found evaporator coil frozen due to critically low refrigerant charge. Allowed system to thaw completely before performing diagnostics. Recharged system with 4+ pounds of R-410A refrigerant to manufacturer specifications. Verified proper operation with 22° temperature split across evaporator coil. System restored to normal cooling operation. Advised monitoring for potential leak given significant refrigerant loss.
Completed annual Family Rewards cooling maintenance visit on Lennox air conditioning system. Performed comprehensive AC tune-up including thorough cleaning of all components, system inspection, and operational testing. Unit operating properly with no issues or deficiencies identified.
Responded to report of upstairs shower drain leak with water shut off to the house. Conducted thorough inspection of tub and drain assembly but was unable to locate any visible source of leaking. Performed water flow test through tub drain system with no leak detected during testing, suggesting issue may be intermittent or related to specific usage conditions.
Responded to no cooling complaint on 20+ year old R22 system experiencing coil freeze-up. Customer had unit off with fan running to allow thawing. Performed diagnostic inspection of blower assembly, air filter, and evaporator coils—all found clean with adequate airflow. Blower capacitor tested slightly below optimal rating but sufficient for full-speed operation. Connected manifold gauges to refrigerant circuit and identified low refrigerant charge as primary cause of freeze condition. Due to system age, R22 refrigerant type, and declining charge indicating potential leak, recommended customer consult with service advisor regarding repair versus replacement options given the obsolete refrigerant and system longevity considerations.
Responded to a toilet leak caused by a malfunctioning fill valve. Removed the toilet tank lid, diagnosed the faulty fill valve assembly, and replaced it with a new unit. Additionally addressed the broken shut-off valve to restore proper water control to the fixture.
Responded to no cooling complaint on system where maintenance was recently completed. Found outdoor unit not operating due to capacitor making contact with low voltage terminal, causing electrical short that damaged both outdoor unit controls and indoor thermostat. Remounted capacitor in proper position to prevent contact with electrical components, replaced damaged thermostat, verified system operation and proper cooling cycle. All repairs completed under warranty.
Responded to no cooling complaint on aging AC system. Upon inspection, discovered air filter completely clogged with white ultrasonic humidifier dust causing high-pitched whistling and excessive blower noise. Removed contaminated filter, which immediately eliminated whistling and reduced motor noise. Proceeded to outdoor unit and performed electrical diagnostics, finding capacitor testing weak and slightly out of specification but still functional. Cleaned condenser coil and cycled system for performance verification. Unit achieved proper cooling with 20° temperature split across coil. Installed temporary filter and provided estimate for capacitor replacement. System operational at time of departure, advised discontinuing use of ultrasonic humidifier to prevent future filter contamination and airflow restriction.
Responded to no cooling call on 20-year-old residential air conditioning system. Upon arrival, found condenser fan motor not operating while compressor was running. Diagnosed failed dual run capacitor preventing fan motor operation. Replaced defective capacitor and verified proper fan motor operation. Performed comprehensive maintenance service including condenser coil cleaning, condensate drain line clearing, and air filter inspection. Conducted system performance testing with refrigerant pressure measurements on suction line, confirming proper operating pressures and adequate temperature differential across evaporator coil. System restored to full cooling operation with no refrigerant leaks or freeze-up conditions detected. Documented equipment condition with photos showing corroded copper refrigerant lines and overall unit wear consistent with age. Advised customer of condenser fan motor condition for future consideration. Unit operating normally at departure.
Replaced heat exchanger on boiler under parts warranty coverage. Also replaced igniter electrode and electrode gasket. Following installation, conducted thorough test run to verify proper operation and inspected all connections for leaks. System tested successfully with no issues detected.
Responded to a clogged bathroom lavatory sink drain that was backing up during use. Diagnostic assessment confirmed the blockage was isolated to the lavatory sink drain line with no other fixtures affected. Cabled the drain line and successfully removed a significant accumulation of hair and sludge buildup causing the obstruction. Upon reassembly, discovered the existing tubular trap was leaking and required replacement. Installed a new tubular trap assembly under the lavatory sink to ensure proper seal and drainage. Conducted final testing to verify proper drain operation and confirmed no leaks were present at any connections.
Responded to emergency water leak at exterior hose bibb that was actively pouring water, requiring immediate shutdown of main water supply to the property. Removed failed outdoor spigot assembly and accessed copper supply line through foundation wall. Installed new frost-free hose bibb with proper seating and connection to existing copper piping, ensuring watertight seal at all connection points. Restored water service to property and verified no leaks at installation site upon pressurization.
Responded to a basement floor drain backup occurring when the washing machine discharged, causing water to overflow from the utility sink onto the floor with extremely slow drainage taking approximately two hours to clear. Upon arrival, verified the complaint and tested all toilets, confirming proper drainage throughout the home, which indicated the blockage was isolated to the floor drain line rather than the main sewer line. Cabled the floor drain line to clear the obstruction and successfully restored flow. Extracted a large accumulation of lint from the drain line, which was the primary cause of the blockage. Following the cable work, performed multiple flow tests by filling and emptying the laundry tub several times to ensure complete clearance and proper drainage function. The floor drain is now operating at normal capacity with no backup or slow drainage issues.
Responded to service call for outdoor hose bibb that would not shut off properly. Upon arrival, confirmed active leak at exterior spigot assembly. Accessed shutoff valve from interior location through unfinished space to isolate water supply. Removed failed hose bibb from exterior wall penetration and inspected mounting hardware and pipe connections. Installed new frost-free hose bibb with proper sealing and secured unit within existing recessed wall box. Restored water supply and tested new fixture under full pressure to verify complete shutoff functionality with no leakage. Confirmed proper drainage and operation of replacement unit.
Responded to no cooling complaint on 2021 Daikin system. Found condenser coils completely plugged with debris, restricting airflow and preventing proper heat rejection. Thoroughly cleaned condenser coils, restored full airflow, and performed complete system checkout with no additional issues found.
Conducted municipal plumbing inspection of existing residential system to assess compliance requirements for water supply and drain-waste-vent (DWV) testing. Performed visual assessment of basement mechanical area, documenting copper piping layout and HVAC connections, as well as attic crawl space where deteriorated pipe insulation was observed on metal supply lines. Comprehensive photographic documentation was captured of all plumbing infrastructure for municipal review to determine specific air testing and pressure testing protocols required for code compliance certification.
Responded to no cool complaint on 8-year-old residential air conditioning system that had never received maintenance service. Upon inspection, found unit operating with low refrigerant charge and heavily soiled condenser coils restricting airflow. Added refrigerant to proper levels and performed thorough coil cleaning. Verified system performance with delta T temperature measurements, confirming adequate cooling capacity restored and unit operating within normal parameters.