Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI between May 2026 and June 2026.
The most recent job was on June 2, 2026.
Responded to no cool call on commercial rooftop unit with no airflow into building. Upon inspection, found blower motor running but blower belt had completely failed and separated, preventing blower wheel operation. Installed spare belt found in unit compartment to restore immediate cooling operation. Observed condenser coil appears partially restricted and recommended follow-up service including new blower belt replacement, air filter change, and condenser coil cleaning to ensure optimal system performance and prevent future failures.
Responded to service call for two toilets cycling on and off every 30 minutes for approximately 15 seconds while not in use. Upon inspection, diagnosed leaking flappers and failing fill valves in both toilet tanks causing phantom flushing and pressure pump cycling. Removed defective components and installed new flappers and fill valves in both units. Tested flush mechanisms and verified proper operation with no leaks. Adjusted water levels and chain lengths to manufacturer specifications. Confirmed pressure pump cycling issue resolved and toilets functioning properly.
Completed annual furnace and air conditioning tune-up on 22-year-old HVAC system. Performed comprehensive inspection revealing multiple components nearing end of service life. AC unit operates with R22 refrigerant and runs louder than normal. Measured compressor amperage drawing higher than specification. Identified contactor with significant pitting and burn marks requiring replacement. Discovered blower motor with oil leakage indicating bearing wear. Control board shows evidence of thermal stress with visible hot spot. Blower wheel heavily coated with dust and debris accumulation. Documented equipment condition with multimeter readings showing 39.97 ÎĽF capacitance measurement. Discussed findings with homeowner who intends to extend system operation for additional years before replacement. Recommended monitoring contactor, blower motor, and control board as priority replacement items to prevent system failure.
Completed comprehensive annual air conditioning tuneup and preventive maintenance service. Performed thorough system inspection beginning with indoor components, verifying air filter condition and confirming condensate drain line was flowing freely without obstructions. Proceeded to outdoor condensing unit where condenser coil was cleaned and washed to remove accumulated debris and ensure optimal heat transfer efficiency. Conducted detailed inspection of all external components including fan motor, compressor, electrical connections, and refrigerant line sets. Connected manifold gauge set to measure system pressures and temperatures across the refrigerant circuit. Verified system is operating within manufacturer specifications with proper temperature differential across the evaporator coil and adequate refrigerant charge levels. All components tested and found functioning properly with no deficiencies noted.
Responded to recurring drainage issue where standing water around floor drain prevented household water usage. Previous drain snaking attempt unsuccessful. Performed intensive drain cleaning using cable machine to clear main line obstruction caused by root intrusion. Extracted significant root mass from drainage system. Restored proper flow and drainage functionality to floor drain and household plumbing system.
Responded to water heater leak reported at top of unit with water damage extending to base. Upon inspection, identified active leaking from unions at top connections of tanked water heater. Visible rust-colored staining and corrosion present on tank surface indicated ongoing water intrusion. Removed failed union fittings and replaced with female pro unions on copper supply lines. Tested connections for proper seal and verified leak elimination. Unit restored to normal operation.
Responded to no hot water call on 80-gallon electric water heater. Diagnosed failed heating elements upon arrival. Drained water heater completely, then removed and replaced both upper and lower heating elements and thermostats. Tested unit operation and verified proper heating function. Additionally reviewed existing water treatment system with customer due to ongoing performance concerns with current service provider.
Responded to kitchen faucet leak caused by damaged sprayer hose. Upon inspection, determined that the hose leak warranted complete faucet replacement to ensure long-term reliability. Successfully removed existing faucet assembly and installed new pull-down kitchen faucet with bronze finish on double-basin stainless steel sink. Tested water flow and spray functions to verify proper operation with no leaks detected. System restored to full working condition.
Responded to customer concern regarding sprinkler system and interior plumbing issues following evaluation by another contractor. Investigated reported leak in basement and diagnosed frozen hose bibb requiring replacement. Removed damaged frozen hose bibb and installed new brass hose bibb with ball valve assembly and backflow prevention device on exterior deck mounting point. Verified proper operation of new fixture and tested for leaks. System restored to full functionality with no active leaks detected upon completion.
Responded to no cooling complaint on 15+ year old R22 air conditioning system. Upon arrival, verified outdoor condenser unit was not operating. Performed diagnostic testing and confirmed compressor failure - unit drew electrical current but failed to build refrigerant pressure. Due to age of system, obsolete R22 refrigerant, and cost of compressor replacement, recommended system replacement and provided comfort advisor consultation for new equipment options.
Responded to no cooling complaint on high velocity HVAC system. Diagnosed failed control board in air handler unit that was intermittently sending 24 volts to system components, preventing proper cooling operation. Removed defective control board and installed replacement unit, restoring proper voltage delivery and system functionality. Verified system operation and confirmed cooling restored.
# HVAC Maintenance Agreement - Service Completed Performed comprehensive AC maintenance tune-up on a 15-year-old residential cooling system per scheduled maintenance agreement. Upon arrival, conducted thorough system inspection and diagnostic testing of all major components. ## Work Performed Completed full system evaluation revealing low R410A refrigerant charge and failing dual capacitor. Utilized digital multimeter to verify electrical readings and confirm capacitor degradation beyond acceptable operating parameters. Conducted refrigerant pressure testing which indicated system was operating below manufacturer specifications. Performed leak search protocol to identify source of refrigerant loss prior to recharge operations. Inspected all connection points, coils, and line sets for potential leak sites. Upon completion of leak detection and necessary repairs, recharged system with appropriate amount of R410A refrigerant to restore proper operating pressures and cooling capacity.
Responded to no cooling complaint on 2-3 year old system following recent maintenance visit. Upon arrival, found system not cooling adequately with evidence of previous freeze-up on evaporator coil. Performed diagnostic testing using refrigerant manifold gauges and confirmed system charge within proper specifications. Verified condenser coil clean and operating correctly. Identified airflow restriction caused by high MERV 12 filter combined with closed basement vents limiting return air. Instructed occupants to open basement vents to improve air circulation. Replaced restrictive filter with standard efficiency filter to restore proper airflow across evaporator coil. Verified blower operation and system cycling properly after corrections. System returned to normal cooling operation with adequate airflow and no further signs of freezing.
Responded to no cooling call on 4-year-old residential HVAC system. Upon arrival, found that condenser coil had been recently cleaned by homeowner after discovering cooling issue. Performed diagnostic testing and identified failed dual capacitor as root cause of system failure. Replaced defective dual capacitor with new component, restored system to proper operation, and verified cooling functionality.
Responded to no cooling complaint on 5-year-old Carrier AC system affecting entire home. Upon inspection, discovered failed capacitor preventing compressor operation. Diagnosed capacitor as completely burned out, rendering outdoor unit inoperable. Provided repair quote to restore cooling functionality, but homeowner elected to postpone repairs at this time. No repairs performed during this visit.
Replaced time delay board in air handler to address fan operation issue. Upon testing, fan still failed to operate, prompting further investigation which revealed a broken green wire for the fan circuit inside the thermostat. Removed broken wire segment, reconnected fresh wire to thermostat terminal, and verified proper fan operation upon system startup.
Completed comprehensive air conditioning tune-up and maintenance visit with no issues found. Performed full system operational testing, cleared condensate drain line, replaced air filter, and thoroughly cleaned outdoor condenser unit. Verified all refrigerant pressures and temperature readings, confirming system is operating within manufacturer specifications.
Completed routine air conditioning maintenance agreement visit with no reported issues. Performed comprehensive system inspection including operational testing, air filter replacement, blower capacitor testing, and condensate drain clearing. Cleaned condenser coil, verified all electrical components, and measured refrigerant pressures and temperatures, confirming all systems are operating within manufacturer specifications.
Responded to service call for excessive condenser noise and inadequate cooling in upper level of residence. Upon arrival, diagnosed noise issue originating from vibrating plastic condenser fan motor shroud rather than compressor assembly. Removed condenser top panel and installed foam tape between shroud and metal housing to eliminate vibration and noise. Verified significant noise reduction with homeowner approval. Performed system diagnostics and discovered refrigerant charge was below manufacturer specifications. Connected manifold gauges and confirmed low refrigerant levels contributing to insufficient cooling capacity in upper zones. Discussed findings with homeowner regarding ongoing performance concerns and necessity of refrigerant recharge to restore proper system operation and cooling efficiency. Documented system conditions and recommended corrective actions for proper refrigerant charge restoration.
Replaced two exterior hose bibs as requested by homeowner. Work required cutting access through interior wall to reach plumbing connections, then installing new frost-free sillcocks on exterior deck area. All connections were properly sealed and tested for leaks to ensure proper function.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.