Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in June 2026.
The most recent job was on June 4, 2026.
Responded to water leak originating from refrigerator water supply line located in drop ceiling area. Upon investigation, accessed the concealed PEX piping system between floor joists and identified a failed PEX tee fitting as the source of the active leak. Evidence of water damage and moisture staining was visible on surrounding wooden structural members. Isolated the water supply, removed the defective PEX tee fitting, and installed a new PEX tee connection using proper crimping techniques to restore water supply to the refrigerator. Verified all connections for proper seal and tested system under full pressure to confirm leak was eliminated and water flow was restored to normal operation.
Responded to scheduled AC tune-up for 22-year-old R22 system. Upon arrival, discovered unit frozen solid with ice accumulation on both the evaporator coil and refrigerant line set. System was not operating properly despite initial customer indication that it was working. Documented frozen conditions with photographs showing ice buildup on exterior line set and current thermostat settings displaying 78°F on hold mode. Due to extent of freezing and age of R22 system, recommended comfort advisor consultation to assess underlying cause of freeze-up and discuss repair versus replacement options given the system's age and obsolete refrigerant type.
Performed comprehensive tune-up on 7-year-old Bryant air conditioning system. Cleaned outdoor condensing unit, tested all electrical components and verified readings within manufacturer specifications. Measured 20-degree temperature drop across evaporator coil, confirming proper system operation. Noted dirty air filter requiring replacement by homeowner.
Responded to complaint of temperature imbalance in split-level residence with freezing conditions on lower level while upper level maintained comfortable temperatures. Performed inspection of ductwork system and all supply registers throughout the home. Found all basement-level registers fully open, resulting in excessive airflow to lower level and insufficient distribution to upper level. Adjusted basement registers to partially closed positions to redirect airflow and balance temperature distribution between levels. Provided homeowner instruction on proper seasonal adjustment of registers to optimize comfort for both heating and cooling seasons. Recommended monitoring system performance over next several days to evaluate effectiveness of airflow modifications.
Completed scheduled air conditioning tuneup on approximately 20-year-old R22 system for new customer. During maintenance inspection, identified multiple critical issues including failed heat exchanger on furnace, severely pitted contactor, delayed compressor start time exceeding one minute, and compressor drawing near maximum amperage. Documented equipment condition with photos and recommended comfort advisor consultation for system evaluation. Advised installation of hard start kit and contactor replacement to address immediate electrical and starting concerns.
Responded to no cooling call on 10+ year old air conditioning system with tripped breaker and non-functioning outdoor unit. Upon inspection, discovered system was slightly undercharged on refrigerant. Added one pound of refrigerant to bring system to proper operating charge, verified acceptable temperature split across evaporator coil, and confirmed outdoor unit returned to normal operation. System restored to cooling capacity with indoor fan and outdoor condenser unit both functioning properly.
Responded to emergency call for frozen outdoor hose bibb that leaked into laundry room. The existing hose bibb had previously been identified as needing replacement and had now failed, causing water intrusion inside the home. Shut off water supply to the affected fixture to prevent further flooding. Removed damaged frozen hose bibb and installed new frost-proof hose bibb with proper valve assembly. Tested new installation for leaks and verified proper operation of shut-off valve with blue handle. Confirmed no additional water intrusion and restored exterior water access.
Responded to report of water appearing on subfloor in hallway adjacent to laundry room during washer operation. Conducted thorough inspection of laundry room plumbing connections, supply lines, drain lines, and washer hookups. No active leaks, moisture, or water damage detected in laundry area or surrounding plumbing fixtures. Determined moisture on hallway subfloor was consistent with residual water tracking from exterior entry point rather than plumbing system failure. Advised homeowner to monitor area for any changes. Additionally, replaced defective shut-off valves serving fixtures in upstairs bathrooms to ensure proper water control and prevent potential future leaks.
Responded to no cooling complaint and found evaporator coil completely iced up with water pooling beneath furnace. Outdoor unit was not operating due to compressor overheating from low suction pressure caused by ice buildup. Allowed compressor to cool and verified unit would fire, then shut system down to permit ice to melt completely. Diagnosed multiple contributing factors to freeze-up condition: dirty air filter requiring replacement, humidifier damper incorrectly positioned in winter mode allowing cold air dump into return plenum (repositioned to summer mode), and faulty RDS board failing to send proper power to thermostat causing intermittent blank screen and erratic fan operation while outdoor unit ran at full capacity. Temporarily bypassed RDS board to restore functionality. Returned on second visit with replacement RDS board and found system running properly with ice melted. Installed new RDS board, configured dip switches to activate sensor one, and verified proper system oper
Responded to no cooling call on aging air conditioning system with no recent maintenance history. Upon inspection, discovered blown wire at exterior disconnect box, along with failed contactor and capacitor. Identified these failed electrical components as preventing system operation and requiring replacement to complete full system diagnostic and restore cooling function.
Responded to no cool call on 21-year-old central air conditioning system. Upon inspection, diagnosed failed dual run capacitor and defective condenser fan motor preventing unit operation. Provided repair estimate for capacitor and fan motor replacement. Scheduled separate system replacement consultation due to age of equipment and noted Carrier WeatherMaker 9200 furnace also nearing end of service life with known model reliability concerns.
Responded to no cooling complaint on 20-year-old R-22 air conditioning system serving one section of home. Upon arrival, engaged thermostat and located air handler in basement crawlspace area. Replaced dirty air filter and proceeded to outdoor condensing unit for diagnostic testing. Connected refrigerant gauges and found system critically low on charge with 60 psi on high side and 0 psi on low side, indicating significant refrigerant loss. Provided customer with pricing options for R-22 leak repair and coordinated follow-up estimate appointment for full system replacement due to age and obsolete refrigerant type.
Responded to no cooling complaint on 19-year-old Carrier Infinity heat pump system. Verified thermostat wiring and voltage at control board, confirmed proper connections at terminal blocks. Diagnosed communication failure between indoor unit and outdoor condenser—system unable to send signal to outdoor unit for cooling operation. Inspected heat exchanger during troubleshooting process. Due to age of equipment and communication board failure, provided part pricing information and scheduled system replacement estimate.
Responded to service call for leaking outdoor hose bib connection. Upon arrival, found compromised garden hose attached to exterior spigot with visible water leakage at connection point, likely resulting from previous amateur repair attempts. Removed damaged hose, inspected hose bib fixture for proper operation and seal integrity, and installed new reinforced garden hose with proper threaded connection to exterior spigot. Tested system under full water pressure to verify leak-free operation and proper flow rate.
Completed comprehensive plumbing inspection of residential property, identifying several items requiring attention during next service visit. Thoroughly evaluated water filtration system, including water softener with digital control head and white filter housing with replaceable cartridge. Determined that water filter replacement is necessary and provided detailed explanation of filtration system operation and maintenance requirements. Inspected bathroom fixtures including sink, faucet, and drain assembly. Documented all findings with photographs of plumbing equipment and fixtures for service records. Advised homeowner of identified deficiencies noted in inspection report to be addressed during subsequent appointment.
Responded to no-water condition on recently installed reverse osmosis system. Diagnosed RO unit failure with full inlet pressure present but no water flow to storage tank, dispensing faucet, or refrigerator line. Troubleshooting identified filter failure or manifold malfunction as root cause. Provided estimate for filter replacement to restore system operation.
Responded to no-cool call on 22-year-old Lennox furnace system with non-operational outdoor condensing unit. Upon inspection, identified multiple critical component failures including blower motor with oil leak, draft inducer motor malfunction, and failed control board exhibiting extensive rust and corrosion damage from moisture exposure. Performed refrigerant leak search on outdoor unit, completed system recharge, and replaced defective blower motor, exhaust inducer motor, and corroded control board. Recommended comfort advisor consultation due to age of equipment and extent of deterioration observed throughout system components.
Responded to no cooling complaint on upper level of residence with 4-5 year old system. Upon arrival, inspected indoor air handler and discovered humidifier bypass damper was positioned in winter mode, restricting proper airflow. Corrected damper position to summer mode for optimal circulation. Verified air filter was clean and in acceptable condition. Proceeded to outdoor condenser unit and found significant debris accumulation on condenser coil affecting heat transfer efficiency. Verified capacitor tested within acceptable range and all electrical connections were secure. Performed thorough condenser coil cleaning to remove dirt, dust, and debris buildup from fins and coil surfaces. Following cleaning, conducted system performance testing including refrigerant pressure and temperature measurements. All pressures and temperatures measured within manufacturer specifications, confirming system is operating properly with adequate refrigerant charge. Adjusted thermostat fan setting from
Completed annual AC maintenance tune-up on 19-year-old R22 system per rewards club membership agreement. Inspected and tested all system components including electrical connections, capacitor operation, and refrigerant levels. Condenser coil fins show significant hail damage causing reduced airflow and operational inefficiency, though customer declined system replacement at this time due to minimal usage patterns and preference for warmer indoor temperatures.
Responded to call for water leaking from joint connection between toilet and water supply line. Upon inspection, identified faulty fill valve as primary source of leak. Replaced defective fill valve and flapper assembly to restore proper operation and eliminate water leakage. Tested system to verify repair and confirm no additional leaks present.