Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in June 2026.
The most recent job was on June 6, 2026.
Responded to water leak emergency at residential property where home security system detected leak in water filtration system. Upon arrival, found old whole house water filter had failed and was leaking. Homeowner had already shut off main water supply to prevent further damage. Assessed the existing blue cylindrical filter unit and determined replacement was necessary. Removed failed filter assembly and installed new spin down filter with proper copper pipe connections. Mounted new white filtration unit on existing wooden backing board, secured all plumbing connections, and tested system for proper operation and leak-free performance. Restored water service to residence and verified all fixtures operating normally.
Responded to no cooling complaint on 10+ year old Goodman air conditioning system. Upon arrival, confirmed unit was not producing cool air and indoor temperature was rising. Performed diagnostic inspection of both outdoor condenser unit and indoor Bryant furnace/air handler system. No ice formation or condensation observed on refrigerant lines during initial visual inspection. Connected testing equipment to outdoor condenser unit to check system pressures and refrigerant charge. Diagnostic testing revealed system was completely empty of refrigerant, indicating a significant leak within the refrigerant circuit. Due to age of equipment and severity of refrigerant loss, recommended full system replacement rather than repair. Scheduled estimate appointment for new AC system installation. Documented equipment conditions with photos of outdoor condenser unit and indoor air handler for replacement planning purposes.
Responded to no cooling complaint on 4-year-old air conditioning system. Found blown low-voltage fuse at furnace control board. Performed comprehensive system diagnostics and discovered resistance to ground on air conditioner contactor circuit. Traced thermostat wiring from outdoor unit back to furnace, inspecting all connections and wire routing through metal straps. Identified multiple contributing factors: conflicting thermostat settings between zones (heat mode in one area, cool mode in another) and exposed thermostat wire on exterior that was repaired with electrical tape. Isolated and tested contactor independently to rule out component failure. After addressing wiring issues and repairing exposed conductor, retested circuit and confirmed no resistance to ground. Replaced low-voltage fuse, reconnected all components, and verified system operation. Unit cycled properly and restored cooling function.
Completed comprehensive plumbing inspection of residential property, including evaluation of mechanical room systems and kitchen plumbing fixtures. Identified downstairs dishwasher requiring proper installation with recommendations to lower drain connection and complete water supply hookup for new unit. Communicated necessary corrective actions to homeowner for completion.
Responded to no-cool complaint on recently installed system with thermostat set to 70°F but only cooling to 76°F. Upon arrival, found outdoor condenser unit moderately dirty and air filter unchanged since installation in October. Cleaned condenser coil, replaced air filter, and activated all three thermostat zones to perform comprehensive system evaluation. Verified 3-ton system airflow at 1200 CFM and adjusted blower speeds, increasing low cooling fan speed by approximately 100 CFM and optimizing dehumidification fan speed for improved performance. Conducted refrigerant charge verification using pressures and temperature measurements, confirming proper charge levels throughout system. System now operating within normal parameters with adequate airflow and cooling capacity restored.
Responded to emergency call for frozen and failed exterior hose bibb that ruptured, causing water to spray inside the residence and resulting in approximately two inches of interior flooding. Coordinated with mitigation team on-site to access the affected area. Cut access hole in interior drywall to reach the damaged freeze-proof sillcock behind the wall cavity. Removed and replaced the failed hose bibb assembly, ensuring proper installation and secure mounting to exterior siding. Verified all connections were watertight and system was functioning properly upon completion.
Responded to no cooling complaint on dual mini-split system. Inspected both units: bedroom mini-split operating normally with clean filters and proper refrigerant levels. Living room mini-split indoor unit powers on but blower fails to operate in auto mode; compressor does not engage and refrigerant does not circulate when fan set to auto. System operates properly when fan manually set to high speed. Diagnosed faulty indoor unit control board. Recommended indoor unit board replacement and scheduled comfort advisor for replacement options.
Completed annual air conditioning maintenance tune-up on a 31-year-old Goodman unit utilizing R22 refrigerant. Identified significant condenser coil corrosion due to animal urine exposure and pitted contactor requiring replacement. Replaced defective contactor and documented equipment condition with photos for comfort advisor review.
Responded to upstairs bathroom sink backup. Homeowner had previously removed and cleaned P-trap without resolving the stoppage. Cabled drain line to clear obstruction, restoring proper drainage and water flow to the fixture.
Completed annual air conditioning maintenance on 3-ton system per maintenance agreement. Tested unit operation and confirmed proper airflow with 20° temperature differential across coil. Verified air filter condition, cleared condensate drain line, and pressure-washed outdoor condenser coil. Inspected all electrical connections and mechanical components. Discovered significant accumulation of animal nesting material (straw/grass debris) around blower motor assembly and refrigerant lines inside air handler cabinet. System operating within normal parameters upon completion of service.
Responded to no cooling call on aging HVAC system with 40+ year-old condenser and 20 year-old furnace that had shut down overnight with no air movement through vents. Upon arrival, found failed blower motor capacitor reading only 3 microfarads out of rated 7.5 microfarads. Replaced defective capacitor and performed quick condenser coil wash during service. After capacitor replacement, system restored to operational status with good cooling performance. Post-repair testing revealed refrigerant charge concerns with superheat measuring approximately 1° and subcooling reading around 50°, indicating potential airflow restrictions or system wear consistent with equipment age. Consulted with technical support regarding airflow and refrigerant readings to determine root cause. Given the advanced age of the equipment and current satisfactory cooling performance, advised homeowner of system condition and potential future concerns related to overall wear. System left in operational condition with
Completed return visit to address temperature cross-over issue where hot water supply was functioning correctly but cold water was running warm, requiring approximately three minutes to achieve proper cold temperature. Installed refrigerator water supply line to provide connection for appliance ice maker and water dispenser functionality.
Completed comprehensive AC tune-up on 6-year-old Carrier system. Performed outdoor unit cleaning, verified all electrical components within manufacturer specifications, replaced air filter, and confirmed proper system operation with satisfactory temperature differential across the evaporator coil.
Responded to basement drain backup issue where drains were slow and backing up during washer use. Inspected septic tank and confirmed it was not full, isolating the blockage to the basement drain line between fixtures and the lift pump station. Cabled the drain line from the basement to the pump tank, successfully clearing the obstruction at approximately 15 feet. No debris was retrieved on the cable. Tested the system by running water and flushing the toilet to verify proper drainage and flow restoration to all basement fixtures.
Responded to service call for condensate pump replacement on commercial rooftop unit. Initially installed replacement condensate pump and tested system operation. Unit failed to operate after pump installation. Proceeded to rooftop to inspect outdoor unit and discovered two blown fuses in the control circuit. Replaced fuses, but they immediately blew again upon system startup. Conducted thorough inspection of all wiring for potential short circuits, damaged insulation, or wires contacting metal surfaces. No visible wiring faults were identified during inspection. Upon further review of equipment specifications, identified root cause of repeated fuse failure. The condensate pump that was initially installed was rated for 120V operation, while the system requires a 208-240V pump. Incorrect voltage rating caused excessive current draw, resulting in blown fuses and potential damage to control boards. The voltage mismatch likely damaged both the indoor and outdoor control boards as well as
Provided estimate for new outdoor hose bib installation near AC unit. Scope includes upgrading existing water line to 3/4" supply, routing through attic space, and penetrating exterior wall adjacent to condenser location. Installation will include dedicated shut-off valve in mechanical room above water main and boiler drain for seasonal winterization to prevent freeze damage. Exterior hose bib will be mounted to post similar to existing AC disconnect switch configuration. Documented site conditions and existing infrastructure with photographs for accurate material specifications and labor requirements.
Responded to service call for non-functional water heater and provided estimate for installation of customer-supplied tanked water heater unit. During initial installation attempt, identified active water leak in system before electrical connection was completed, preventing potential electrical hazard and water damage. Installation was halted to address leak issue and ensure safe, code-compliant connection of new water heater to existing plumbing and electrical systems in mechanical room.
Responded to a completely clogged bathroom sink drain in an older home with a history of slow drainage and suspected cast iron pipe corrosion. Removed the existing P-trap assembly, which sustained damage during removal and required replacement. Cabled the drain line to its full accessible length using a drain snake to clear the blockage within the branch line. Successfully opened the drain and restored proper flow, though no debris was retrieved on the cable. Installed a new P-trap assembly and tested the system for proper drainage and leak-free operation, confirming full functionality upon completion.
Completed Family Rewards cooling maintenance visit on 4-year-old heat pump system. Performed comprehensive AC tune-up including condenser coil rinse and system performance verification. Measured operating temperatures and confirmed proper system operation of Lennox equipment.
Responded to service call for inadequate cooling and weak airflow. Upon inspection, discovered a leaking evaporator drain pan causing water to cascade onto the secondary heat exchanger, blower assembly, and furnace components. Found extensive rust and corrosion on burners, gas valve, and ECM blower motor due to ongoing water intrusion. Secondary heat exchanger showed water saturation and debris accumulation, contributing to restricted airflow. The AC system (1990) and furnace (2013) both exhibited moisture damage throughout. Diagnosed that evaporator coil replacement is necessary to resolve the leak at its source. Recommended complete evaporator coil replacement along with cleaning of secondary heat exchanger and blower wheel to restore proper system operation and prevent further water damage to furnace components.