Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in June 2026.
The most recent job was on June 19, 2026.
Performed comprehensive AC tune-up on 6-year-old system. Conducted full system inspection beginning with indoor unit, checking air filter which was found to be heavily soiled; homeowner will replace filter independently within the week. Verified evaporator drain line was clear and draining properly, confirmed blower motor speeds were correctly configured for system specifications. Proceeded to outdoor condensing unit and performed electrical component inspection. Tested capacitor which measured within manufacturer specifications, verified contactor showed no signs of pitting or wear. Removed top panel and pressure-washed condenser coils to remove accumulated debris and restore heat transfer efficiency. Reassembled unit and initiated startup sequence, allowing system to run for 15-minute operational test. Measured supply and return air temperatures confirming 19-degree temperature differential, indicating proper refrigerant charge and system performance. All components operating as de
Completed comprehensive air conditioning and furnace tune-up on 5-year-old HVAC system. Replaced dirty humidifier pad and system filter to restore proper airflow and humidity control. All equipment inspected and found operating within normal parameters with no issues identified at this time.
Performed comprehensive air conditioning tune-up on 2-year-old system. Identified humidifier damper in winter position causing excessively cold return air; adjusted damper to proper setting and achieved appropriate 20-degree temperature differential. Tested system operation, verified condensate drain clear, performed condenser coil cleaning, and inspected all components with satisfactory results. Noted air filter nearing end of service life and recommended replacement at next interval.
Responded to a clogged bathtub drain caused by accumulated hair buildup. Manually removed the drain stopper assembly and extracted the hair blockage from the drain line, restoring proper drainage. Verified water flow and confirmed the fixture was functioning correctly upon completion.
Performed comprehensive maintenance on a 6-year-old Lennox air conditioning system per membership agreement. Conducted thorough inspection of evaporator coil, blower assembly, condenser unit, contactor, compressor, and all related components. Replaced air filter, verified refrigerant charge levels within manufacturer specifications, and cleaned condenser coil to restore optimal heat transfer efficiency. System tested and confirmed operating within normal parameters upon completion of tune-up service.
Responded to no heat call on 10+ year old furnace following recent AC installation. Upon inspection, discovered condensate drain line plugged at floor drain, causing water backup into draft inducer motor and pressure switches, resulting in pressure switch failure and system lockout. Cleared drain blockage, removed water from draft inducer motor and pressure switch assembly, and restored system to proper operation.
Completed comprehensive HVAC maintenance agreement including furnace and air conditioner tune-ups. Replaced air filter, cleared condensate drain line, and inspected blower compartment. Performed exterior condenser coil cleaning and component inspection, discovering minor coil damage from animal urine exposure and vegetation contact. Documented equipment make, model, and serial numbers, and identified missing liquid line service valve cap requiring replacement.
Completed comprehensive AC tune-up and maintenance service on residential cooling system. Performed thorough cleaning of outdoor condensing unit, replaced humidifier pad, and cleaned indoor components. System inspected and found to be in good working condition with no issues identified.
Responded to a callback for a leaking outdoor hose bibb that was causing water infiltration into the basement, resulting in floor damage. Upon arrival, identified that the hose bibb was leaking from the handle despite a recent repair attempt. Replaced the defective hose bibb with a new unit to eliminate the leak and prevent further water damage to the interior space.
Completed comprehensive HVAC maintenance on 8-year-old Armstrong air conditioning unit and 9-year-old Armstrong furnace. Performed AC tune-up including system performance evaluation, flue gas analysis showing 94.8% efficiency with acceptable combustion readings (13 ppm CO, 7.8% O2), and electrical measurements confirming proper amperage draw. Customer reported outdoor unit operating louder than normal; inspection confirmed unit functioning correctly within manufacturer specifications with both heating and cooling systems in good working order.
Completed comprehensive A/C maintenance on one R-410A condenser system with ambient temperature at 61 degrees. Performed full system inspection including filter, thermostat operation, temperature split measurement, condenser unit, evaporator and condenser coils, motors, capacitors, compressor functionality, refrigerant charge levels, and condensate drain line. Identified dual-run capacitor (45+5 ÎĽF) reading out of manufacturer specifications and recommended replacement for optimal system performance; customer declined repair at this time. Also recommended air filter replacement. System currently operating within normal parameters with no refrigerant leaks detected and all other components functioning as designed.
Responded to no hot water call on a 50-gallon natural gas water heater. Upon inspection, diagnosed failed pilot assembly preventing unit from maintaining flame and heating water. Due to age and condition of the existing Bradford White 38-gallon unit and extent of component failure, provided estimates for complete water heater replacement rather than repair of the pilot assembly system.
Performed comprehensive A/C maintenance on single condenser unit with R-410A refrigerant system. Conducted full system inspection including filter, thermostat, temperature drop measurement, condenser coils, motors, capacitors, compressor, refrigerant levels, and condensate drain. System was reported to be running extended cycles and struggling to maintain cooling during hot, humid conditions. Diagnostics revealed low refrigerant charge. Added UV leak detection dye and recharged system to proper operating levels. System tested and confirmed operating normally upon completion. Provided recommendations for future repairs and documented equipment specifications.
Responded to emergency service call for furnace leaking water extensively throughout unit, with water accumulation reaching the burner box. Identified the root cause as a completely blocked AC condensate drain line, which caused water to back up into the furnace while the air conditioning system was operating. Removed all standing water from burner box and furnace cabinet, then cleared the plugged condensate drain line to restore proper drainage function. Tested AC system operation to verify proper drainage after clearing blockage. Performed complete outdoor condenser unit maintenance including coil cleaning and component inspection. During thorough inspection of furnace, discovered failed heat exchanger requiring replacement. Documented all findings with photographs of outdoor condenser unit showing accumulated debris and electrical connections. Advised customer of heat exchanger failure and scheduled follow-up appointment for replacement estimate and options.
Completed comprehensive A/C maintenance on one condenser unit utilizing R-410A refrigerant with an outside ambient temperature of 56 degrees. Performed full system inspection including air filter, thermostat operation, temperature differential measurements, condenser unit, evaporator and condenser coils, blower motor, capacitors, compressor function, refrigerant charge levels, and condensate drain line. Documented equipment make, model, and serial number information with photographs of electrical panel and tested system components using digital multimeter. All system components checked and found operating within normal parameters at time of service completion.
Completed comprehensive AC tune-up on 4-year-old system addressing concerns about extended run times. Performed full system operational testing, verified blower capacitor functionality, confirmed condensate drain line clear, pressure-washed outdoor condenser coil, and inspected all components. System achieved proper temperature differential of 49.4°F at supply register and is operating within manufacturer specifications; advised air filter replacement due.
Completed comprehensive plumbing inspection of residential property. Inspected toilet tank internal components, noting functional flush mechanism with flapper valve and float assembly in working condition; observed mineral deposit buildup on tank interior surfaces typical of normal wear. Examined shower plumbing fixtures including handheld shower hose assembly and chrome wall mounting bracket, confirming proper installation and operational condition.
Responded to emergency service call for non-operational sewage pump causing floor drain backup in basement utility area. Upon arrival, assessed failed sewage ejector pump system that had been previously evaluated by drain cleaning team. Removed heavily soiled and inoperative sewage pump from sump basin, which showed significant accumulation of debris and grime indicating system failure. Installed new sewage pump with proper electrical connections and discharge piping configuration. Tested new pump operation to ensure proper functionality and verified discharge flow through existing white PVC piping system. System restored to full operational status with floor drain backup issue resolved.
Responded to water leak in mechanical room originating from water filter housing. Upon inspection, found filter housing leaking during filter removal and reinstallation, with water draining under wall. Eliminated the problematic filter housing to resolve the ongoing leak issue.
Responded to service call for gas line disconnection due to kitchen appliance conversion from gas cooktop to electric convection oven. Disconnected gas supply line at island location and traced line back to main supply connection near furnace. Removed gas line from supply point and properly capped connection at furnace using appropriate brass fittings. Capped both ends of disconnected gas line to preserve for potential future use. Performed comprehensive leak check on all capped connections using approved testing methods to verify system integrity and safe operation. All connections tested and confirmed secure with no gas leaks detected.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.