Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in June 2026.
The most recent job was on June 30, 2026.
Responded to no cool call on 6-year-old Goodman air conditioning system. Upon arrival, confirmed outdoor unit was not receiving power and system was non-operational. Diagnosed failed control board on indoor furnace unit, which was preventing proper communication between thermostat and outdoor condenser. Control board showed no voltage output to contactor circuit despite proper incoming power and thermostat signal. Replaced defective integrated furnace control board and restored all low-voltage wiring connections to proper terminals. Verified thermostat communication, tested system startup sequence, and confirmed outdoor unit now engaging properly with adequate amperage draw. System cooling normally with proper temperature split across evaporator coil. Also assessed water heater for potential maintenance scheduling per customer request.
Responded to no cooling complaint on 23-year-old R-22 system with 6-degree temperature differential between setpoint and actual room temperature. Upon arrival, found evaporator coil completely frozen, preventing proper heat exchange and airflow. Homeowner reported previous refrigerant recharge performed several years ago, indicating potential ongoing leak in system. Due to frozen condition of coil, unable to perform complete diagnostic testing including static pressure measurements at time of service. Documented existing system configuration including ECM blower motor in current furnace. Observed ongoing comfort issues with inadequate cooling to second floor, consistent with possible airflow restrictions, undersized ductwork, or insufficient system capacity for multi-level application. Previous technician had attempted to address zoning issues through manual damper adjustments at supply registers. Provided detailed explanation of R-22 refrigerant phase-out, leak repair options, and a
Responded to no cooling complaint on residential air conditioning system over 10 years old. Upon arrival, diagnosed blown fuse preventing unit operation. Replaced failed 25-amp time-delay fuse with Bussmann heavy-duty replacement. Verified proper system operation, confirmed adequate refrigerant levels, and restored cooling function to the home.
Successfully installed customer-supplied kitchen faucet in residential kitchen. The new pull-down faucet with curved spout in brushed nickel finish was mounted above the sink area, with all connections properly secured and tested for leaks. Installation was completed after reviewing pricing details with the homeowner prior to commencing work.
Responded to no cooling complaint on residential air conditioning system. Found failed capacitor that had been previously installed by our company. Capacitor had catastrophically failed and required replacement. Replaced defective capacitor under warranty at no charge to customer. System tested and verified proper operation with adequate cooling restored.
Conducted on-site assessment for water heater replacement options. Customer requested quote for heat pump water heater installation with preference for 40-gallon gas unit. Documented existing Richmond Integra 6-year warranty gas water heater installation, photographed current mechanical room configuration including furnace, water softener system, plumbing connections, and copper piping with shutoff valves for accurate replacement planning and specifications.
Responded to no cooling complaint with 7-year-old Nest thermostat that lost WiFi connectivity after modem replacement. Successfully reconfigured and reconnected Nest thermostat to new network, restoring system operation. Customer declined further system inspection, requesting setup only for incoming homeowners on Bryant single-stage heating and cooling system.
Returned to site to power up Mitsubishi mini-split unit following previous component replacement. Upon energizing the system, unit clicked on but displayed open circuit fault codes. Diagnostic testing revealed two blown fuses on the control board preventing operation. Documented fuse specifications with photographs for parts ordering and scheduled follow-up visit to install replacement fuses and restore unit to full operation.
Responded to return visit for commercial rooftop unit not cooling. Found blower motor operating but compressor and condenser fan not running. Diagnosed tripped high-pressure switch, reset unit, but switch tripped again within 10 minutes. Identified severely plugged condenser coil as root cause of high-pressure condition. Performed thorough coil cleaning using water hose for approximately 45 minutes to flush accumulated debris and restore proper airflow. Reset system after cleaning and verified proper operation with compressor running continuously for over 30 minutes with normal cooling restored.
Responded to a no cooling call on a 12-year-old Carrier air conditioning system. Upon arrival, diagnosed a failed capacitor preventing the unit from operating. Replaced the capacitor and restored cooling functionality. During inspection, identified that the outdoor condenser unit has been sitting with a significant tilt since original installation, causing improper oil distribution within the compressor and inadequate lubrication of internal components. Advised customer that the prolonged tilted position has likely caused internal compressor damage and poses ongoing risk of complete compressor failure if not corrected. Discussed repair and replacement options with customer and scheduled follow-up consultation with service advisor to address the condenser leveling issue and evaluate system condition.
Completed comprehensive AC maintenance on 14-year-old system as part of annual maintenance agreement. Identified dual capacitor operating outside manufacturer specifications and recommended replacement to prevent system failure. Performed full system inspection, documented equipment condition with photos of furnace and water heater installations, and verified all other components operating within normal parameters.
Responded to no cooling complaint on 17-year-old Lennox air conditioning system. Upon arrival, diagnosed intermittent low voltage fuse failure occurring when system engaged. Traced issue to outdoor condenser unit where rodent damage had compromised low voltage wiring, causing short circuit between exposed conductors. Replaced damaged wire section with new low voltage wiring and secured connections. During system evaluation, identified condenser fan capacitor reading out of manufacturer specifications and noted significant dirt accumulation on furnace blower wheel affecting airflow efficiency. Discussed repair options with homeowner and completed low voltage wire replacement to restore system operation.
Responded to no cooling call on 33-year-old R22 system. Upon arrival, found indoor fan operational but outdoor unit not running consistently. System started and ran normally during diagnostic period, indicating possible intermittent compressor or electrical issue. During inspection, identified cracked heat exchanger in furnace, creating safety hazard. Due to age of equipment, obsolete refrigerant type, and compromised heat exchanger, recommended comfort advisor consultation for system replacement options rather than repair of aging equipment.
Responded to no cooling condition on rooftop packaged unit and found blower belt had come off again. Installed spare belt found in unit to restore cooling operation temporarily. Submitted parts order for new blower belt and filters, and requested pricing for replacement blower pulley due to observed wear that may be causing premature belt failure. Unit operational at time of departure, pending installation of new belt and potential pulley replacement to prevent recurrence.
Responded to an upstairs bathroom leak causing water damage and ceiling sagging on the main floor below. Upon investigation, identified a broken trap adapter on the bathtub that was leaking water during tub operation. Removed and replaced the defective trap and trap adapter assembly, then performed water flow testing to verify proper installation and confirm leak elimination.
Responded to no cooling call on five-year-old residential air conditioning system. Upon inspection, discovered burnt line voltage wires at the contactor, preventing compressor operation. Replaced failed contactor with new unit, verified all electrical connections were secure and within manufacturer specifications, and restored system to normal cooling operation.
Responded to warranty call for residential air conditioning unit experiencing excessive power draw and loud clunking noise during startup and shutdown cycles. Upon arrival, diagnosed compressor hard-start issue on unit installed six months prior. Installed hard start kit to condenser unit, which significantly reduced startup noise and eliminated the loud clunking sound during compressor cycling. Tested system operation to verify proper functionality and confirmed quieter operation. Additionally provided homeowner with recommendations to improve airflow from cabinet-mounted supply vent. System now operating within normal parameters with improved startup performance.
Responded to no-cooling complaint on residential split system with approximately 40-year-old General Electric Weathertron outdoor unit. Upon inspection, found severely restricted airflow due to plugged A-coil, failed blower motor with oil leakage contaminating internal components, and cracked heat exchanger presenting safety concern. Discussed findings and system condition with homeowner, including age-related equipment failure and safety issues. Coordinated comfort advisor consultation for system replacement recommendations given extensive component failures and advanced age of equipment beyond economical repair.
Installed customer-supplied Kohler thermistor component for electronic shower system. Replaced faulty part, restored water supply, and verified proper temperature control operation through digital interface panel, confirming accurate temperature adjustment functionality.
Responded to service call for 40-gallon natural gas tanked water heater experiencing active leak from bottom of unit. Upon arrival, confirmed 9-year-old Richmond brand water heater had ruptured tank with water actively leaking from base. Determined unit was beyond repair and required complete replacement. Removed and disposed of failed water heater, then installed new Bradford White 40-gallon natural gas water heater with proper venting and code-compliant connections. Connected copper supply lines with brass fittings and shutoff valves, installed gas line with appropriate yellow-tagged safety valve, and verified all plumbing connections for leaks. Tested unit operation, confirmed proper ignition and heating function, and ensured all safety features were operational before completing installation.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.