Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in July 2026.
The most recent job was on July 20, 2026.
# Kitchen Sink Drain Repair Responded to a water leak originating from the kitchen sink drain connection. Upon inspection, identified a cracked plastic coupling nut at the tailpiece connection point, which was causing water to seep during drainage. The deteriorated nut showed visible signs of stress fractures and mineral buildup, compromising the seal integrity of the P-trap assembly. Removed the failed coupling nut and replaced it with a new white PVC slip joint nut, ensuring proper threading and hand-tightening to manufacturer specifications. Verified all connections within the P-trap assembly were secure and tested the repair by running water through the drain system to confirm leak elimination and proper drainage flow.
Responded to service call for tanked water heater experiencing leaking from the temperature and pressure relief valve with indicator light flashing. Upon inspection, confirmed active leak at relief valve and assessed potential tank compromise. Successfully replaced defective temperature and pressure relief valve to restore proper system operation and eliminate water discharge. System tested and verified operational following repair.
Responded to service call for Rheem ProTerra Performance Platinum heat pump water heater displaying error code A108, indicating condensate drain blockage with heating source defaulting to backup elements. Upon arrival, verified unit was producing hot water and operating on electric elements. Inspected condensate drainage system including rope sensor, drain tube, and drain line connections. Found rope sensor dry with no moisture present and confirmed drain line clear of obstructions with no residual water accumulation. Performed vacuum test on condensate fitting to verify proper drainage flow. Disconnected and reconnected rope sensor to test system response; alarm persisted after brief interval despite clear drainage path. Based on diagnostic findings—clear drain lines, dry sensor, and recurring alarm code despite proper drainage—determined likely failure of condensate rope sensor itself rather than actual blockage condition. Confirmed unit remains under manufacturer warranty coverage.
Responded to service call for bathtub drain trim kit installation. Upon inspection, discovered existing tub drain was non-standard configuration and incompatible with the brushed nickel trim kit. Provided estimate for accessing drain assembly through wall or floor access point and replacing with standard tub drain assembly to accommodate proper trim kit installation.
Responded to a no cooling call for a ground-level air conditioning unit. Upon inspection, discovered rodent-damaged wiring and a blown capacitor in the condenser. Replaced the failed capacitor, repaired all damaged wiring connections, and cycled the system to verify proper operation. Checked refrigerant levels, indoor blower, and air filter. System restored to normal operation.
Installed two chrome-finished safety grab bars in residential shower enclosure to improve accessibility and prevent falls. Bars were securely mounted to wall studs per ADA guidelines, with one horizontal bar positioned along the tub entry point and proper placement verified for optimal support during entry, exit, and showering activities.
Conducted site assessment for complete baseboard heating system replacement throughout residential unit. Inspected existing fin tube baseboard elements in all rooms and documented deteriorated conditions requiring full replacement. Measured all baseboard runs and compiled comprehensive parts list including baseboard enclosures, copper fin tube elements, and mounting hardware necessary to complete installation. Photographed existing equipment conditions showing aged copper piping, worn insulation, and current baseboard configurations for reference during parts procurement and future installation phase.
Responded to no cooling call on 6-year-old Carrier system. Found unit low on R-410A refrigerant. Added 3 pounds of refrigerant and injected UV dye into system to facilitate future leak detection. Verified system operation with 16-degree temperature differential across evaporator coil. Advised customer of refrigerant loss indicating potential leak and provided estimate for system replacement as alternative to ongoing refrigerant additions.
Responded to service call for 6-year-old Goodman air conditioning system not maintaining adequate cooling during peak heat hours. Upon inspection, found refrigerant charge slightly low. Discussed repair options and long-term system considerations with homeowner. Customer elected to defer additional repairs at this time. Recharged system to proper specifications and verified operation.
Responded to water leakage issue at furnace causing moisture accumulation in basement. Diagnosed and cleared plugged condensate drain line, restoring proper drainage function. Performed exterior cleaning of unit due to excessive dirt buildup and completed operational tuneup. Verified system heating and cooling functions operating within normal parameters upon completion.
Completed kitchen sink conversion from dual-basin to single-basin configuration. Reconnected kitchen drain plumbing using PVC P-trap assembly, ensuring proper alignment and secure connections to vertical drain lines. Verified garbage disposal unit connections, water supply lines, and tested system for proper drainage and leak-free operation.
Responded to no cooling call on 25-year-old residential air conditioning system. Diagnosed indoor blower motor failing to maintain operation due to defective run capacitor testing at 8 out of 10 microfarads. Replaced failed capacitor, installed new air filter, and performed condenser coil cleaning to restore system functionality. System returned to normal operation with adequate airflow and cooling capacity. Noted system appears overcharged but has operated in this condition since installation without issue. Identified damaged section of condensate drain line requiring future repair and provided replacement pricing to customer.
Responded to condensate leak at furnace with water accumulation underneath unit. Found severely clogged air filter and piece of insulation blocking condensate pan and drain line. Removed debris, cleared condensate drain system, and performed complete system tuneup on AC unit including cleaning of coils and inspection of all components. System restored to proper operation with cooling functioning as designed. Recommended immediate filter replacement to prevent future issues.
Responded to return service call for intermittent no cool condition on split air conditioning system. Upon arrival, confirmed unit was cycling on and off erratically with compressor and outdoor fan motor shutting down unexpectedly. Performed diagnostic testing and traced fault to defective contactor relay controlling power supply to compressor and condenser fan motor. Verified failure by manually tapping relay, which caused unit to shut off and restart, confirming internal contact degradation. Observed significant debris accumulation and evidence of previous rodent intrusion in outdoor unit. Provided customer with pricing for contactor relay replacement to restore reliable system operation.
Completed callback service to relocate water heater to its original position following basement waterproofing and drain tile installation. Reconnected all plumbing lines, gas connections, and venting system to the relocated water heater unit. Verified proper operation of all connections and documented final installation with photographs showing completed mechanical room setup with water heater, associated piping, and auxiliary equipment properly positioned and functioning.
Responded to no cooling complaint on 8-year-old residential AC system with indoor temperature at 85°F. Upon arrival, confirmed indoor blower and outdoor fan motor were operating, but compressor was not running. Verified air filter condition and airflow at supply registers. Proceeded to outdoor unit and performed electrical diagnostics on compressor circuit. Testing revealed dual-run capacitor had failed on compressor terminal, reading zero microfarads and preventing compressor from starting. Replaced defective capacitor with manufacturer-specified dual-run capacitor. Energized system and verified compressor startup and proper operation. Confirmed unit cooling effectively and returning to normal temperature setpoint.
Completed routine cooling maintenance on 1-year-old residential air conditioning system per service agreement. Customer reported unusual popping noise at startup and intermittent sounds from both indoor and outdoor units; however, no abnormal sounds were detected during inspection and operation. Replaced air filter, cleared condensate drain line, and performed condenser coil cleaning on outdoor unit. Verified all electrical components, measured refrigerant pressures and temperatures, and confirmed system is operating within manufacturer specifications with proper cooling performance.
Completed annual air conditioning maintenance and tune-up on residential HVAC system. Performed comprehensive system inspection including test run of air conditioner, verified new air filter installation, confirmed humidifier damper set to summer position, cleared condensate drain line, and performed condenser coil cleaning with component inspection. All equipment operating within normal parameters with supply air temperature reading 53.7°F and evaporator coil showing proper heat exchange function.
Responded to a water leak issue caused by a malfunctioning humidifier supply line in the attic mechanical space. Successfully capped the humidifier supply line to eliminate the active leak and prevent further water damage to the surrounding insulation and building materials.
Responded to water leak complaint from downstairs HVAC air handler unit. Upon inspection, identified clogged evaporator coil condensate drain line as source of water backup. Cleared obstruction from drain line and removed accumulated dust and debris from drain pan to prevent future clogs. Flushed drain line thoroughly with water to ensure complete clearance and verify proper drainage flow. System now draining properly with no backup occurring.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.