Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in July 2026.
The most recent job was on July 27, 2026.
Responded to callback on 9-month-old AC installation with no cooling complaint. Upon diagnosis, confirmed compressor failure and identified improper installation with unit positioned directly against home exterior. Tested capacitor with digital multimeter to verify electrical component functionality. Replaced failed AC unit and relocated condenser 6 inches away from brick wall to ensure proper airflow and clearance per manufacturer specifications. Unit now operational with adequate spacing for maintenance access and optimal performance.
Responded to no cooling complaint on a 2012 residential air conditioning system. Upon arrival, found the outdoor condensing unit inoperative with customer reporting louder than normal motor operation prior to failure. Diagnostic testing identified a failed dual run capacitor preventing compressor and condenser fan motor operation. Replaced defective capacitor with proper OEM-spec replacement, restored power to unit, and verified normal compressor and fan motor startup with proper amperage draw. System cycled properly and returned to normal cooling operation.
Responded to no cooling complaint on unit less than 10 years old. Upon arrival, system was empty of refrigerant following previous service visit where fluorescent dye had been injected for leak detection. Successfully located refrigerant leak at aluminum joint on condenser coil using UV leak detection equipment. Due to elevated mounting position of outdoor unit, coil replacement will require cutting unit down from current installation, removing and replacing condenser coil, then complete reinstallation of equipment. Recharged system with refrigerant to restore cooling operation temporarily. Unit currently operational but requires follow-up visit for condenser coil replacement and reinstallation to permanently resolve leak issue.
Responded to no cool complaint with water leaking near furnace in utility closet. Upon inspection, discovered active water leak originating from evaporator coil drain pan area on 25-year-old R22 air conditioning system. Determined leak was caused by either improper drain pan pitch or cracked drain pan at rear of coil. Additionally found evaporator coil improperly installed without coil shelf support—unit was resting only on screws mounted in plenum, contributing to drainage issues. System still operational but requires immediate attention to prevent water damage. Presented customer with options to further investigate and repair evaporator coil assembly or pursue full system replacement given age and R22 refrigerant status.
Responded to no cooling complaint on 1-year-old central air conditioning system. Upon arrival, confirmed outdoor condensing unit was operational but indoor blower motor was not running continuously. Performed diagnostic testing and found blower motor receiving proper voltage but cycling on and off intermittently. This malfunction caused evaporator coil to ice up, resulting in loss of cooling capacity. Tested blower motor at multiple speed settings to isolate the issue, confirming internal motor failure regardless of speed tap selection. Diagnosed faulty blower motor requiring replacement due to internal component failure preventing sustained operation. Replacement blower motor required to restore proper system function and airflow.
Replaced defective ASME pressure relief valve on IBC boiler system that was actively leaking. Drained system water, disassembled necessary components to access the failed relief valve, cut out the old valve, and installed new pressure relief valve using proper fittings. Re-pressurized the system, verified all connections were secure and leak-free, and confirmed proper operation of the boiler unit.
Responded to no hot water condition on commercial tankless water heater. Found intake blocked error code caused by condensate backup in exhaust system. Discovered exhaust drain pipe completely obstructed with approximately 6 inches of standing water due to severe internal corrosion and rust accumulation. Cleared blockage from condensate drain line, removed accumulated water, and reassembled exhaust components. Verified proper drainage function and restored unit to operational status.
Responded to callback from recent system installation to assist with thermostat programming and mobile connectivity. Successfully configured Lennox digital thermostat for remote access and connected homeowners' mobile devices to enable app-based control and monitoring. System now fully operational with remote temperature adjustment capabilities functioning properly.
Completed phone follow-up regarding water heater replacement estimate and invoice discount inquiry. Customer accepted estimate for warranty water heater replacement after tank developed leak following relief valve replacement from prior service appointment.
Responded to no cooling complaint on 12-year-old air conditioning system. Upon arrival, verified system was running but failing to achieve adequate cooling. Performed diagnostic testing on outdoor condenser unit, including capacitor testing which showed slightly low readings but within acceptable range. Checked refrigerant pressures and found abnormal readings indicating poor refrigerant circulation through the system. Conducted component testing and system analysis to isolate the issue. Diagnostics confirmed internal compressor failure preventing proper refrigerant pumping and heat transfer. Explained findings to homeowner, noting that compressor failure is common in systems of this age. Due to the age of the unit and cost-effectiveness of repair versus replacement, coordinated with service advisor to schedule estimate for complete system replacement.
Responded to service call for Whirlpool water softener with no water entering the unit and brine tank not filling. Diagnosed issue as a stuck venturi assembly preventing proper water flow and regeneration cycle operation. Inspected system components including valve assembly, plumbing connections, and brine tank to confirm diagnosis. Documented findings with photographs and provided estimate for venturi assembly replacement to restore full softener functionality.
Responded to a no hot water complaint on a tankless water heater installed in May 2024. Customer reported intermittent hot water lasting only five minutes during shower use after resetting a tripped breaker. Diagnosed faulty lower heating element causing inadequate water heating capacity. Replaced defective bottom element under warranty, restoring full hot water functionality to the system.
Completed annual AC maintenance tune-up on Carrier condensing unit. Replaced air filter that had not been serviced in over six months. Verified evaporator drain line was flowing properly and confirmed blower fan speeds were operating within specifications. Inspected outdoor unit electrical components and tested capacitor, which measured 32 microfarads against rated capacity of 40 microfarads, indicating weakened performance. Cleaned condenser coil by rinsing debris and buildup from fins. Advised homeowner of capacitor condition and recommended replacement to prevent potential compressor failure; homeowner elected to discuss with spouse before authorizing repair.
Performed comprehensive AC tune-up on 4-year-old Lennox outdoor unit. Rinsed condenser coil and exterior components to remove debris and improve heat transfer efficiency. Conducted full system inspection of all accessible components including electrical connections, refrigerant lines, and condensate drainage. System demonstrated proper operation with 15°F temperature split across the evaporator coil and active condensate production, confirming adequate cooling capacity and dehumidification. All components functioning within normal parameters at time of service completion.
Responded to service call for non-functional garbage disposal that had seized up. Removed and eliminated the existing garbage disposal unit from under the kitchen sink. Reconfigured the drain plumbing with appropriate PVC P-trap connections to accommodate the sink drain without a disposal unit, ensuring proper drainage and code-compliant installation.
Completed Family Rewards cooling maintenance visit on residential HVAC system. Performed comprehensive air conditioner tuneup including operational testing, air filter replacement, and condensate drain clearing. Cleaned condenser coil and inspected all exterior components. During diagnostic testing, identified weak capacitor on compressor side. Verified refrigerant pressures and temperatures within manufacturer specifications. Replaced defective capacitor to restore optimal system performance and prevent potential compressor failure.
Responded to service call for reverse osmosis system producing abnormal hissing, groaning, and gurgling noises. Inspected under-sink RO unit and identified issues with system operation. Evaluated filtration components and determined filter replacement was necessary to restore proper function. Repositioned drain line to eliminate noise and improve drainage performance. System tested following repairs to verify quiet operation and proper water flow.
Completed comprehensive membership air conditioning maintenance and tune-up on multi-zone HVAC system. Tested and verified proper operation of air conditioner and all three zone dampers. Inspected air filter and condensate drain, both found clean and functioning properly. Performed outdoor condenser unit cleaning and thorough inspection of electrical components, measuring 3.31 amps draw. Connected manifold gauges to verify refrigerant pressures and temperatures, confirming all system parameters within manufacturer specifications and optimal operating condition.
Performed comprehensive AC maintenance and system evaluation on aging 35-40 year old unit. Inspected all AC components and furnace elements, identifying failing control board and exhaust fan requiring attention. Documented system condition with photos of control board showing wire connections and component layout, and recommended replacement of draft motor and contactor to ensure continued reliable operation.
Responded to emergency call for broken PVC vent pipe in attic. Upon inspection, discovered a 3-foot crack in the vent pipe caused by freezing conditions after roofing contractors improperly pushed the pipe down during previous roof work. The damaged pipe ran from the attic through the laundry room and back out through the roof. Removed and replaced the compromised section of PVC piping, restoring proper ventilation system function. Documented conditions with photos showing the attic workspace, insulation, existing pipe routing, and structural components for record purposes.