Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in August 2026.
The most recent job was on August 7, 2026.
Responded to a no hot water complaint on a gas-fired tanked water heater where the pilot light would not remain lit. Diagnosed a faulty thermocouple preventing proper flame sensing and gas valve operation. Removed the defective thermocouple assembly, installed a new replacement unit, and verified proper pilot ignition and flame retention. Confirmed hot water restoration and normal water heater operation upon completion.
Responded to emergency call for water heater leaking and spraying steam from top of unit, causing basement flooding. Upon arrival, found 12-year-old Rheem Performance water heater with failed braided supply line as source of leak. Shut off water supply to house and turned off water heater to stop steam discharge. Removed and replaced defective braided supply line with new unit, restored water supply, and verified system operation with no leaks present.
Completed annual cooling maintenance and AC tune-up on residential split system with no reported issues. Performed comprehensive inspection of indoor air handler unit in basement mechanical room and outdoor condenser unit, including evaluation of refrigerant levels, electrical connections, condensate drainage system, ductwork connections, and overall system operation. All components found to be functioning within normal parameters and system left in proper working condition.
Responded to master bathroom toilet producing gurgling and bubbling noises that began three days prior. Upon arrival, performed multiple flush tests with and without toilet paper to replicate the reported issue. Toilet operated normally during inspection with no abnormal sounds detected. Tested all bathroom fixtures including shower and sinks to verify proper drainage and venting. All plumbing fixtures functioned correctly with adequate drainage and no gurgling present. Assessment indicates likely temporary vent blockage that self-cleared prior to service visit. Advised homeowner to monitor toilet operation and contact for follow-up if symptoms return.
Responded to service call for leaking natural gas water heater in basement utility area. Upon inspection, confirmed water heater was actively leaking from drain valve and unit showed signs of age-related deterioration. Homeowner requested full replacement rather than repair. Removed existing water heater and installed new 50-gallon natural gas tank-type water heater. Connected all supply and discharge plumbing lines, installed temperature and pressure relief valve with proper discharge piping, and reconnected gas line with appropriate fittings and shutoff valve. Tested all connections for leaks, verified proper venting, and confirmed unit operation and temperature settings before completing installation.
Completed annual AC and furnace maintenance inspection on a 13-year-old system, evaluating safety, efficiency, and reliability of both units. During furnace testing, discovered inducer motor was stuck and would not allow system to start; manually freed the motor and system operated normally afterward, though this component may require monitoring or replacement in the future to prevent failure. Performed exterior condenser unit cleaning, inspected all AC components which were found to be in good working condition, and noted refrigerant charge was slightly low but system is currently maintaining adequate cooling performance.
Responded to water leak emergency in basement ceiling area. Upon inspection, identified pinhole leak in copper piping configuration (3/4" x 1/2" x 3/4" tee fitting). Performed minor copper repipe to repair compromised section and restore water integrity. Leak source confirmed to be related to plumbing line rather than outdoor spigot or dishwasher connection as initially suspected.
Responded to no hot water complaint and water softener leak in mechanical room. Upon arrival, found water softener drain line missing, causing water to spray throughout the space and extinguish the pilot light on the 40-gallon Bradford White natural gas water heater. Inspection revealed additional leak at the water softener bypass valve. Installed new drain line on water softener, replaced o-rings on bypass assembly to eliminate leak, and successfully relit pilot light on water heater. Verified proper operation of both units before completing service.
Responded to a leak under the kitchen sink related to a reverse osmosis system installed two days prior. Upon inspection, identified the RO threaded tank valve as the source of the leak. Tightened the tank valve connection, which resolved the leak completely. Performed water quality testing at the kitchen sink to verify system performance: hardness measured at 0 grains per gallon, iron at 0 parts per million, kitchen cold water at 323 total dissolved solids, and RO tap water at 23 total dissolved solids, confirming proper filtration operation.
Completed comprehensive plumbing repairs in bathroom, including replacement of shower head, faucet, spigot, and tub drain. Additionally installed natural gas line for kitchen stove, with brass shutoff valve and proper mounting brackets secured to framing. All connections tested and verified for proper operation and safety compliance.
Returned to property to complete shower head installation following earlier appointment. Successfully installed replacement shower head unit on chrome shower arm in bathroom with herringbone-patterned tile. Verified proper water flow and secure mounting upon completion.
Performed comprehensive AC tune-up on Lennox condenser unit, including outdoor coil cleaning, electrical component inspection, air filter replacement, and evaporator drain line verification. Identified and provided estimate for rusted and broken furnace exhaust elbow requiring replacement. Diagnosed thermostat orange warning light issue caused by incorrect battery type in outdoor temperature sensor; recommended lithium batteries for proper operation with option to disable sensor if problem persists.
Completed standard height toilet replacement in accordance with call of work specifications. Removed existing toilet fixture and installed new unit with elongated front bowl. Replaced wax ring seal and mounting bolts to ensure proper watertight connection to closet flange. Secured toilet to floor, connected water supply line, and tested for leaks and proper flushing operation. Installation completed successfully with all components functioning as intended.
Responded to service call for leaking toilet. Upon inspection, identified that the cast iron toilet flange was installed too high, preventing proper seal and causing water leakage around the base. Removed the existing cast iron flange and installed a cast iron repair flange at the correct height to ensure proper toilet mounting and watertight seal. Leak resolved and toilet restored to normal operation.
Completed comprehensive air conditioning preventive maintenance service. Thoroughly cleaned outdoor condenser unit to remove debris and ensure optimal airflow. Inspected and tested all electrical components, confirming all readings were within manufacturer specifications. Replaced 5-inch air filter at indoor unit. Verified system performance with 20-degree temperature differential across evaporator coil, confirming proper refrigerant charge and airflow. System operating efficiently with no deficiencies noted.
Completed preventive maintenance tune-up on a 7-year-old Goodman central air conditioning system originally installed in 2018. Performed comprehensive AC inspection including filter replacement with 14x20x1 filter, verified evaporator coil was clean with proper drainage, conducted electrical testing with all readings within manufacturer specifications, cleaned outdoor condenser unit, and ran system through full operational cycle for 15 minutes confirming proper performance with temperature split exceeding 17 degrees across the coil. All components functioning properly with no deficiencies noted.
Responded to service call for detached dryer vent in utility closet. Found flexible duct completely disconnected from exterior wall termination point due to inadequate mounting lip on exterior vent opening. Installed new dryer vent termination with proper mounting flange to secure flexible ductwork connection. Reattached flexible dryer vent duct to new termination point, ensuring proper seal and support. Performed operational test of dryer unit to verify adequate airflow and proper venting function. System operating correctly with no restrictions.
Responded to service call for leaking outdoor spigot. Upon arrival, inspected the exterior hose bibb at the base of the brick structure and assessed the condition of the fixture and surrounding area. Provided detailed estimate for complete hose bibb replacement and installation to resolve the leak issue and restore proper function to the outdoor water supply.
Completed scheduled HVAC maintenance agreement service on a 3-year-old system. Performed comprehensive furnace and air conditioning tune-up, finding all components operating within manufacturer specifications. Replaced dirty Healthy Climate MERV 16 filter and thoroughly cleaned outdoor condensing unit. Tested system operation with 15-minute run cycle at maximum cooling capacity, confirming proper performance of all equipment.
Responded to report of toilet leaking into ceiling below. Upon inspection, found severely rusted toilet flange with potential subfloor compromise requiring replacement. Provided estimate for flange replacement and subfloor repair work with expectation to schedule completion. Completed comprehensive Family Rewards plumbing inspection of property, examining water heater, supply lines, shut-off valves, under-sink plumbing connections, garbage disposal unit, and all accessible plumbing fixtures and components. Documented conditions with photographs for customer records.
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.