Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in August 2026.
The most recent job was on August 14, 2026.
Responded to service call regarding elevated CO2 levels in residence with Lennox HVAC system installed in 2023. Performed comprehensive system inspection including examination of fresh air intake system, exhaust venting configuration, and overall operational status. Utilized inspection camera to evaluate interior condition of venting system and verified proper combustion air supply. System found to be operational with no immediate safety concerns; customer scheduled for follow-up evaluation and indoor air quality assessment to address ventilation requirements.
Responded to emergency call for burst PEX ice maker line that caused water damage to basement ceiling. Removed damaged ceiling materials to access failed line, then replaced entire ice maker supply line with new copper piping for improved durability and longevity. Additionally, installed new toilet fixture and replaced faulty trap on basement lavatory sink to resolve drainage issues.
Responded to kitchen sink leak at basin connection where the basket strainer seal was spinning and unable to tighten properly. Removed the failed basket strainer assembly and installed a new replacement unit, ensuring proper sealing and secure mounting to eliminate the leak. Tested the installation for proper drainage and confirmed no further leakage at the connection point.
Responded to no heat condition on 3-year-old Navien boiler displaying error code E110 indicating low airflow on intake. Inspected concentric vent system and found intake obstructed with spiderwebs and ladybugs. Cleared all debris from intake vent, restoring proper airflow to unit. Tested boiler operation through complete heating cycle to verify proper temperature rise. Confirmed system pressure within normal operating range. Unit restored to full operational status with proper heating functionality.
Completed comprehensive maintenance on 2019 Amana furnace and air conditioning system. Performed full furnace inspection including removal and cleaning of burners and flame sensor, verified all electrical components, inspected blower compartment, cleared condensate drain and pressure switch ports, tested and adjusted gas pressure to manufacturer specifications. Confirmed proper furnace operation and verified air filter condition. Proceeded to air conditioning maintenance by clearing condensate drain line, performed condenser coil cleaning to remove debris, inspected outdoor unit components, and verified system performance through refrigerant pressure and temperature readings. All systems tested and confirmed operating within normal parameters.
Completed annual plumbing maintenance inspection as part of preventative maintenance plan. Installed two new toilets to replace existing fixtures. Repaired pinhole leak in copper water line. Replaced malfunctioning exterior hose bibb with new frost-free faucet. Replaced gasket on Rusco inline water filter screw-in cap as requested. Inspected Bradford White Defender water heater and verified proper operation of all plumbing systems. All installations tested and confirmed leak-free with proper water flow and drainage.
Completed annual cooling maintenance on a 12-year-old air conditioning system as part of membership agreement. Performed comprehensive AC tune-up including operational testing of all system functions. Verified air filter was clean and in good condition. Cleared condensate drain line to ensure proper drainage and prevent water backup. Inspected blower compartment and verified all internal components for proper operation. Proceeded to outdoor unit where condenser coil was thoroughly washed to remove debris and restore optimal heat transfer efficiency. Inspected all exterior components including fan motor, contactor, and capacitor. System tested and confirmed to be cooling properly with all components functioning as designed.
Responded to no hot water call for boiler system that was initially not igniting but was operational upon arrival. Diagnosed intermittent failure of domestic hot water production caused by suspected zone board malfunction preventing proper power delivery to circulation pumps. Tested system during hot water call, confirmed both domestic hot water pump and return line pump receiving correct voltage and operating normally at time of inspection. Recommended zone board replacement to address intermittent power supply issue, with plan to monitor system for recurrence to confirm diagnosis. Additionally inspected air conditioning unit per report of clicking noise and observed warping condensing unit pad, but found no active issues with fan operation, wiring, or debris interference during visit.
Responded to callback for water softener experiencing intermittent leaking one to two times per month since recent installation. Upon inspection, identified source of leak as failed discharge adapter with visible split causing water to saturate carpeted floor beneath unit. Removed damaged discharge adapter and installed new replacement component. Verified all connections secure and tested system operation to confirm leak resolved. No further issues detected at time of completion.
Responded to no cooling complaint on 12-15 year old Trane rooftop unit serving dining room. Customer reported previous contractor replaced blown fuse in disconnect, but system ran briefly before blowing another fuse. Performed comprehensive diagnostic including visual inspection of all wiring for shorts or damaged insulation, tested both capacitors for proper capacitance values, and performed ohm checks on both compressors to verify motor windings. Inspection revealed multiple issues: condenser coil heavily soiled with significant physical damage, R-22 refrigerant leaks detected on unit, and double-row condenser coil requiring coil splitting for proper cleaning due to debris buildup between rows. External coil condition shows deterioration. Provided customer with pricing options for fuse replacement, refrigerant leak repair, system recharge, and condenser coil cleaning. Customer may require condenser coil replacement depending on extent of damage and cleaning feasibility.
Responded to no cooling complaint on 7-year-old residential air conditioning system. Upon diagnostic evaluation, discovered refrigerant line set had been punctured by a nail during recent flooring installation. System assessment revealed dual capacitor testing significantly below manufacturer specifications. Replaced failed dual capacitor to restore proper compressor and condenser fan motor operation. Used refrigerant manifold gauges to verify system pressures and diagnose refrigerant leak from damaged line set. Provided quote for line set repair, which requires customer approval before scheduling completion of refrigerant circuit restoration.
Completed comprehensive plumbing inspection as part of recurring maintenance service for 5-year gas water heater system. Thoroughly examined all accessible plumbing components including water supply lines, PEX distribution piping, drainage systems, and water heater connections in utility area. All plumbing systems were found to be in good working condition with no leaks, corrosion, or deficiencies noted at time of inspection.
Responded to warranty callback for Liberty Pumps 40S series gravity pump system that had previously backed up. Upon inspection, diagnosed failed float switch preventing pump activation. Documented existing pump assembly and malfunctioning float mechanism. Provided estimate for float switch replacement to restore proper operation.
Responded to water leak in basement ceiling. Upon arrival, water supply had already been shut off by homeowner. Accessed damaged ceiling area and confirmed pinhole leak in 1/2" copper elbow joint. Removed affected section of piping and replaced damaged elbow and adjoining pipe with new fittings. Pressure tested repaired section to verify integrity of connections and restored water service to home.
Completed annual Family Rewards cooling maintenance visit on 21-year-old AC system. During inspection, identified failing dual capacitor and contactor, which were replaced to restore proper system operation. Recommended comfort advisor consultation due to age of equipment and condition observed during service.
Completed scheduled preventive maintenance on both air conditioning and furnace systems per Family Rewards membership agreement. Performed comprehensive tune-up procedures on Daikin furnace and outdoor AC unit with no issues or concerns reported by customer. All systems inspected, tested, and operating within normal parameters upon completion.
Responded to install callback for wall-mounted Lennox heat pump unit with leveling issues on rear gable wall. Removed homeowner-installed wooden shims that were causing excessive forward tilt. Successfully leveled unit front to back, but left-to-right leveling could not be completed due to 6-foot elevation and single-technician ladder access limitations. Submitted install correction form for crew to return with proper equipment to complete left-to-right leveling adjustment of wall-mounted brackets.
Performed comprehensive annual cooling maintenance tune-up on residential split system, including outdoor Carrier condenser unit and wall-mounted mini-split air handler. Completed full system inspection, verified refrigerant levels and line set integrity, tested electrical connections at disconnect box, inspected condensate drainage, cleaned condenser coils, and confirmed proper airflow and operational performance. No issues identified; system operating within normal parameters with no service recommendations required at this time.
Completed comprehensive preventative maintenance tune-up on 4-year-old Bryant air conditioning system. Performed full system inspection including thermostat calibration and operation verification, air filter assessment, blower assembly inspection, outdoor condenser coil examination, electrical component testing, contactor and capacitor evaluation, condensate drain line check, refrigerant charge analysis, and supply/return air temperature differential measurements. All operational parameters measured within manufacturer specifications with no mechanical deficiencies or safety hazards identified. System confirmed operating at optimal efficiency. Advised homeowner on importance of regular filter replacement, maintaining clean indoor and outdoor coils, and adhering to scheduled preventative maintenance to ensure continued reliable performance and longevity of equipment.
Completed comprehensive HVAC maintenance agreement service including air conditioning and furnace tune-ups on a 10-year-old Goodman system with a 2026 campaign maintenance date. Performed standard preventive maintenance procedures on both heating and cooling equipment, inspected all components, verified proper operation of the Lennox furnace and AC system, and documented equipment condition with photos. No issues or deficiencies were identified during the inspection, and all systems are operating within normal parameters.