Hudson’s housing market looks very different from many communities across western Wisconsin. Near Historic Downtown Hudson, the Octagon House Museum, and the St. Croix River, you’ll find homes that have stood for generations. Travel toward County Road F, County Road A, Heritage Greens, or the Troy Burne area, and you’ll see neighborhoods built within the last two decades featuring advanced Air Conditioning and Heating systems, smart home technology, and increasingly sophisticated electrical infrastructure.
That variety creates very different service needs from one property to the next. On any given day, our technicians may be servicing a boiler in an older riverfront home, installing a whole-home generator in a newer subdivision, or helping a homeowner improve humidity control in a house overlooking the St. Croix Valley. Understanding how Hudson has grown allows us to make recommendations that fit the specific home rather than offering a one-size-fits-all solution.
When homeowners in Hudson call about cooling problems, temperature is often only part of the story. Humidity plays a major role in how comfortable a home feels, particularly for properties located closer to the St. Croix River, North Hudson, and other lower river valley areas. Even when temperatures remain reasonable, excess moisture can leave a home feeling uncomfortable and force air conditioning systems to work harder than necessary.
Many homeowners assume they need a larger air conditioner when the real issue is humidity management, airflow design, or aging equipment that is no longer operating efficiently. We regularly help homeowners improve comfort while reducing energy usage by addressing the actual cause of the problem.
Whether your air conditioner struggles to keep up, certain rooms stay warmer than others, or humidity becomes a constant frustration, our team can help identify the right solution.
Hudson homeowners deal with two very different air quality challenges throughout the year. During the summer, humidity can make homes feel damp and uncomfortable. During the winter, months of furnace operation can leave indoor air excessively dry, affecting comfort throughout the home.
Many homeowners are surprised by how much indoor air quality impacts their day-to-day comfort. Dust buildup, inconsistent humidity levels, pet dander, and poor airflow often contribute to issues that homeowners mistakenly blame on their heating or cooling equipment.
The right combination of filtration and humidity control can improve comfort, protect furnishings, and help AC and Heating equipment perform more efficiently throughout the year.
Anyone who has spent a winter in Hudson understands how quickly conditions can change. One week may bring relatively mild temperatures, while the next delivers subzero wind chills and significant snowfall. Those rapid weather swings place tremendous stress on heating equipment and expose weaknesses that may have gone unnoticed earlier in the season.
For many Hudson residents, reliability is just as important as efficiency. A large percentage of local homeowners commute daily along Interstate 94 into Minneapolis or St. Paul. Nobody wants to return home after a long day to discover the furnace stopped working hours earlier. That is why preventative maintenance and proactive system upgrades remain such a priority throughout the area.
Whether you’re maintaining an existing system or evaluating replacement options before winter arrives, we can help you make a confident long-term decision.
Hudson’s continued growth has created increasing demand for electrical upgrades. Newer homes often include electric vehicles, home offices, smart home systems, advanced Heating and Air Conditioning equipment, and entertainment systems that place greater demands on electrical infrastructure than homes built decades ago.
We continue to see strong demand for panel upgrades, backup generators, surge protection, and EV charger installations throughout neighborhoods like Willow River, Troy Burne, Stone Pine, and newer developments along County Road F. Many homeowners are choosing to make these upgrades proactively rather than waiting for electrical limitations to become major problems.
Whether you’re planning future upgrades or dealing with an existing electrical concern, our team can help ensure your system is ready for today’s demands.
Many Hudson homes feature finished basements, updated living spaces, and valuable personal property that can be vulnerable to water damage. Between spring storms, heavy rainfall, frozen pipes, aging water heaters, and sump pump failures, plumbing issues can become expensive very quickly if not addressed promptly.
We regularly help homeowners protect their homes through preventative plumbing improvements, water quality upgrades, and fast repairs when problems occur. Whether you’re in a newer development or an older home near downtown, protecting your plumbing system helps protect the value of your property.
From water heater replacements and filtration systems to emergency leak repairs and sump pump installations, we help homeowners prevent small problems from becoming major repairs.
Hurlburt Heating & Plumbing has completed 20 jobs in Hudson, WI in August 2026.
The most recent job was on August 19, 2026.
Performed comprehensive air conditioning tune-up and maintenance inspection per service agreement. Tested system operation and verified air filter condition, confirmed condensate drain was clear and flowing properly. Cleaned outdoor condenser coil, inspected all exterior components, and measured refrigerant pressures and temperatures to confirm system operating within manufacturer specifications with proper temperature differential in conditioned space.
Performed comprehensive air conditioning tune-up on unit less than 10 years old. Tested system operation and verified proper cooling performance throughout. Inspected blower compartment, cleared condensate drain line, and cleaned outdoor condenser coil. All components functioning within normal parameters. Recommended air filter replacement within the next few months to maintain optimal airflow and system efficiency.
Completed comprehensive air conditioning tune-up and maintenance agreement service. Tested system operation and verified proper cooling performance with satisfactory temperature differential across evaporator coil. Replaced dirty air filter, cleared condensate drain line, and inspected blower compartment for proper operation. Performed exterior condenser coil cleaning to remove debris and ensure optimal heat transfer, inspected all electrical components and connections, and confirmed all system parameters are within normal operating specifications.
Responded to service call for reported water condensation behind furnace. Upon thorough inspection of HVAC equipment and surrounding area, determined that moisture issue was unrelated to heating or cooling systems. Identified source of water leak as faulty pressure gauge on main water supply line. Documented plumbing components with photos and recommended scheduling licensed plumber to address water line issue.
Responded to a service call for a toilet that was running constantly. Upon inspection, determined that the existing American Standard fill valve had failed and was no longer functioning properly. Removed the old fill valve and installed a new replacement unit to restore proper operation. Due to the skirted toilet design, which presents additional complexity for fill valve replacement, advised the customer to monitor the fixture for any potential leaks or drips following the repair.
Completed annual cooling system maintenance on 9-year-old Carrier air conditioning unit as part of preventative maintenance agreement. Performed comprehensive system inspection including evaporator coil, blower assembly, condenser unit, contactor, compressor, and all related components. Replaced air filter, verified refrigerant charge levels at proper specifications, and cleaned condenser coil to ensure optimal heat transfer. Measured supply air temperature at 59.9°F, confirming adequate cooling performance. All components operating within normal parameters with no deficiencies noted.
Responded to a plumbing service call for a malfunctioning toilet water supply system. Upon arrival, found a defective angle stop valve and broken supply line connecting to the toilet. The homeowner had already replaced both the faulty angle stop and damaged braided flex supply line prior to technician arrival. Verified proper installation of the new chrome-plated angle stop valve with shutoff handle and braided stainless steel flex hose connection. Confirmed no active leaks at connection points and proper water flow to fixture. Collected standard service fee for the visit.
Installed a 45-degree B-vent elbow on the Lennox furnace to properly adjust exhaust vent direction while maintaining adequate airflow. Secured all exhaust vent sections with appropriate fasteners, as the existing vent pipe segments were improperly installed without screws and not adequately connected. All exhaust components now properly fastened and secured to manufacturer specifications.
Responded to a service call for a continuously dripping exterior hose bibb. Removed and replaced the faulty hose bibb stem with new parts to restore proper shut-off function and eliminate the leak. The replacement stem was successfully installed, resolving the water drip issue and returning the fixture to normal operation.
Responded to commercial RTU service call to restore cooling operation. Upon arrival, replaced blown fuses and performed comprehensive electrical diagnostics, discovering 0.8 megohm resistance from compressor black leg to ground while other legs showed open line readings. Installed new fuses and energized unit successfully. Unit initially cycled on high head pressure, requiring thorough condenser coil cleaning to resolve the issue. After coil cleaning, unit operated within normal parameters. Checked both refrigerant circuits with gauge set, confirming proper operating pressures and adequate R22 charge levels with no refrigerant addition required. Both circuits running as designed with stable operation achieved.
Performed comprehensive air conditioning tune-up and maintenance under membership agreement. Inspected evaporator coil, blower assembly, air filter, condenser unit, condenser coil, contactor, compressor, and all system components. Identified compressor noise during startup and replaced failed capacitor with new unit. Installed hard start kit to assist with compressor startup and reduce mechanical stress. Verified refrigerant charge at proper levels, confirmed condenser coil cleanliness, and tested zone board and damper operation. System restored to normal operation with improved compressor performance.
Responded to reported gas leak on water heater control valve nipple as identified by utility company. Upon arrival, restored gas supply and performed comprehensive leak detection testing using soap solution on all gas line fittings, connections, and the control valve nipple. No active gas leaks were detected at any test points. Per customer request due to upcoming relocation and for safety precautions, shut off gas supply to the water heater. Water heater was producing hot water and functioning properly at time of service.
Replaced two exterior hose bibbs that were leaking or non-functional, installing new frost-free sillcocks with proper shutoff valves. Additionally, removed and replaced a corroded saddle valve serving the refrigerator water line that was causing low water pressure issues in the kitchen. All new copper connections were soldered, tested for leaks, and verified for proper operation and adequate water flow.
Responded to report of water dripping from round ductwork serving the second floor. Used inspection camera to thoroughly examine the interior of the ductwork and found no evidence of water stains, rust, or moisture damage inside the duct system. Conducted external inspection of the ductwork and observed water marks running down the exterior surface. Determined the issue to be condensation forming on the outside of the duct as it runs through an uninsulated chase from the garage area. Recommended insulating the space around the ductwork in the chase to eliminate the temperature differential causing condensation buildup.
Responded to call for toilet that would not stop running. Diagnosed failed fill valve causing continuous water flow into tank. Replaced defective fill valve with new unit and installed new flapper to ensure proper tank seal and shutoff function. Tested system for proper operation and verified toilet now fills and shuts off correctly.
Performed comprehensive air conditioning tune-up and maintenance on two HVAC systems: a 6-year-old Daikin unit and a 25-year-old Trane unit. Conducted thorough inspection of evaporator coil, blower assembly, condenser, condenser coil, contactor, compressor, and all associated components. Replaced air filter with homeowner-provided filter, verified refrigerant charge levels were within manufacturer specifications, and performed condenser coil cleaning to optimize heat transfer efficiency. All systems tested and confirmed to be operating within normal parameters with no deficiencies noted.
Responded to kitchen faucet malfunction where spray head was broken and fixture was stuck between spray and regular flow modes. Assessed the damaged components and provided estimate for complete faucet replacement to restore proper functionality.
Replaced defective inducer motor on residential furnace under warranty. Removed old motor assembly, installed new unit, verified all electrical connections, and tested system operation. Furnace cycled properly with inducer functioning correctly and all safety controls operating as designed.
Responded to emergency service call for severed refrigerator water supply line located under kitchen lazy Susan cabinet. Upon arrival, found active water leak filling multiple 5-gallon buckets after a plate had fallen and completely cut the drinking water line. Shut off water supply to refrigerator to stop flooding. Removed damaged section of water line that had been cleanly severed. Installed new water line section, coupled connections together securely, and properly fastened and secured line within lazy Susan cabinet to prevent future damage. Tested system for proper operation and verified no additional leaks present.
Responded to service call regarding elevated CO2 levels in residence with Lennox HVAC system installed in 2023. Performed comprehensive system inspection including examination of fresh air intake system, exhaust venting configuration, and overall operational status. Utilized inspection camera to evaluate interior condition of venting system and verified proper combustion air supply. System found to be operational with no immediate safety concerns; customer scheduled for follow-up evaluation and indoor air quality assessment to address ventilation requirements.