We’ve assisted homeowners for over 65 years and will proudly service your home as well.
Minnesota is known for its cold winter weather, and the average high temperatures in Hopkins are well below freezing from December through February. When the cold hits, you can count on our heating experts to make sure your family keeps warm. Our technicians can take care of your furnace, boiler, or heat pump, ensuring it’s correctly maintained and deftly handling any repairs. If you’re struggling with a cold house, we won’t rest until it’s fully warm again. We can also help you enjoy greater comfort by upgrading your house with a new, high-efficiency heating system.
We’re Ready to Assist With Heating Services:
- Heating Repair: Even minor problems can put your heating at risk of giving out suddenly or shortening its lifespan. That’s why you should look to us for prompt heating repairs.
- Heating Installation: Tired of your heating bills rising year after year? Don’t wait until it’s too late! Contact us to get the new system you need.
- Heating Maintenance: Our reliable maintenance services are a great way to save on your energy bills and get the most out of your heating. With the Hurlburt Family Rewards Program, you’ll get discounted repairs and save even more!
Looking for ways to stay cool this summer without breaking the bank? Our service technicians can expertly maintain and repair your AC so it always works efficiently during our often hot and humid weather. We understand how frustrating and stressful it can be when your home is constantly too hot. We offer top-notch ACs, heat pumps, and mini-splits and will help you find the ideal new cooling system for your home.
Depend on Us for These Cooling Services:
- Cooling Repair: If your AC seemingly never shuts off or causes your electricity bill to spike, we can get it fixed straight away. We work on all brands and all types of cooling equipment and can handle any problem.
- Cooling Installation: If you live in an old home without ductwork, a mini-split AC system is the perfect solution to keep you cool. Have an old AC or heat pump that no longer works well? Ditch it and beat the heat with a new central cooling system from Hurlburt.
- Cooling Maintenance: Don’t struggle with frequent breakdowns and subpar energy efficiency. Our maintenance experts will keep your AC in peak condition. Experience the highest level of service and support with the Hurlburt Family Rewards Program!
See all of our HVAC services in Hopkins.
The worst thing you can do when it comes to your plumbing is neglecting issues that need to be fixed. Even a seemingly minor thing like a dripping faucet can cost you greatly due to the amount of water it wastes. No repair is too big or too small for our experienced plumbers to handle. Whether it’s insufficient hot water or a slab leak, we’ll help you overcome it. As one of the most experienced plumbing companies in the area, you can rely on us for professional installations and upgrades as well.
See all of our plumbing services in Hopkins.
Want to make 100% certain your electrical system is safe? Our team can identify any electrical hazards in your home and make sure they’re fully eliminated. Whether it’s smoke coming from an outlet or a switch that feels hot, count on us for rapid, reliable assistance. Upgrading your home with a new electrical panel is a great way to save on electricity costs. We can also keep you prepared for power outages with a backup generator and perform any other installation.
How Our Electricians Can Help You:
- Electrical Repair: We take pride in performing quality electrical repairs and improving electrical safety. From dead outlets and flickering lighting to malfunctioning circuit breakers, we’ll fix whatever problems your home has.
- Electrical Installation: Do you have an EV and are sick of slow charging speeds? Let us help by installing a new Level 2 charging station. We’re adept at installing all other types of electrical equipment and components and are ready to put our skills to work for you.
No matter if your house is near ArtStreet, the Pavilion, or the Artery, we’re ready to serve you. With more than 450 houses that are 100+ years old, Hopkins has a whole lot of historical charm. Whether you live in one of these homes or something newer, we can meet your needs while treating your house with the care and respect it deserves.
For more than 65 years, Hurlburt has been cultivating long-lasting partnerships with area homeowners by offering them honest advice and unbeatable service and support. The thousands of five-star reviews we’ve received are a testament to the quality of work we perform. We also believe in giving back however we can as a way to say thanks to our community.
For assistance from a dependable, trustworthy plumbing, electrical, and HVAC company, contact Hurlburt in Hopkins today!
Hurlburt Heating & Plumbing has completed 20 jobs in Hopkins, MN between July 2026 and August 2026.
The most recent job was on August 6, 2026.
Completed return visit for previously diagnosed HVAC system failure. Installed new large dual capacitor (35+7.5 MFD) and contactor (up to 3-pole, 50 amp) to replace failed components. Verified proper electrical readings with clamp meter, confirmed system operation, and tested cooling functionality to ensure complete restoration of unit performance.
Responded to a residential plumbing service call for a clogged shower drain backup combined with a biannual plumbing inspection. Upon diagnostic evaluation, determined the tub drain was blocked with an accumulation of hair causing slow drainage and standing water. Cabled the tub drain line using appropriate drain cleaning equipment and successfully extracted a large hair ball obstruction from the drain system. Thoroughly cleaned the tub area and performed water flow testing to verify proper drainage was restored. The drain was flowing freely with no backup at completion. Conducted comprehensive biannual plumbing inspection including examination of water heater, washing machine connections, laundry hoses, and leak detection throughout the accessible plumbing system. During water heater inspection, observed significant corrosion present on the water heater drain valve. Made the decision not to perform standard drain flush procedure due to risk of inducing leaks from the corroded drain
Completed annual cooling maintenance on 6-year-old Daikin central AC system and mini split unit. Central AC inspection confirmed contactor, capacitor, refrigerant charge, and amp draws all within specifications; condenser and evaporator coils clean; temperature drop measured at 20 degrees. Mini split system operating properly with 25-degree temperature drop. Replaced furnace filter during inspection. Critical finding: discovered cracked heat exchanger in 15-year-old furnace; recommended full furnace replacement due to age and safety concerns, with part quote to follow for customer consideration.
Responded to a recall service for a bathroom sink with a malfunctioning drain stopper. Upon inspection, identified that the sink pivot rod assembly had come loose, preventing the pop-up drain mechanism from operating properly. Tightened the retaining nut securing the pivot rod to the drain tailpiece, restoring full functionality to the stopper assembly.
Responded to emergency plumbing service call for burst copper pipe in residential property. Conducted comprehensive assessment of plumbing system, identifying multiple areas requiring repair and replacement including laundry room fixtures, bathroom faucets, and main water shut-off valve. Successfully replaced laundry room faucet with new chrome fixture, restoring full functionality to the washing machine water supply. Addressed the burst copper pipe emergency to prevent further water damage. Documented existing conditions through photography, capturing ceiling-mounted plumbing components and newly installed fixtures. Prepared detailed estimates for remaining work including installation of additional bathroom faucets and replacement of main shut-off valve. Customer approved laundry faucet replacement, which was completed during this visit. Additional repairs scheduled for future appointment pending customer approval of estimates.
Responded to no cooling complaint on three RTU units at commercial facility with approximately 12 total rooftop units. Initial diagnostic visit was shortened due to inclement weather conditions. On Unit 16 serving the welding room, identified one failed compressor that customer elected not to repair, and discovered condenser fan motors inoperative—traced issue to blown fuses requiring replacement on return visit. Confirmed cracked heat exchanger on second unit, which customer has chosen not to repair due to pending lease expiration. Third unit requires additional diagnostics to be completed on scheduled return trip. Documented electrical components and fuse assembly with photos for reference. Return visit needed to install fuses, restore condenser fan operation on Unit 16, and complete diagnostics on remaining non-cooling unit.
Responded to service call for toilet malfunction. Upon inspection, identified faulty flapper causing continuous running and cycling. Replaced deteriorated flapper with new component. Post-installation testing revealed toilet continues to slowly drain and refill approximately every 30 minutes, indicating additional underlying issue requiring further diagnosis. Documented existing Kohler toilet tank components and overall plumbing system configuration including water heater installation for reference.
Performed comprehensive maintenance on one A/C system with 410A refrigerant under 83-degree ambient conditions. Inspected indoor air handler including filter, drain pan, blower motor, electrical wiring, and components with all items found in acceptable condition. Verified proper temperature split across evaporator coil. Inspected outdoor condensing unit including coil cleanliness and capacitor condition. Measured amp draw on blower motor, compressor, and contactor with all readings within manufacturer specifications. Verified refrigerant charge at proper levels. Identified aging capacitors (15mfd and 45+5mfd) showing signs of wear and provided replacement estimates for future consideration. System operating normally at completion of maintenance agreement service.
Responded to callback for recently installed 2-ton A/C system not cooling to temperature. Found system was overcharged with refrigerant causing excessively high pressures and poor performance. Removed excess refrigerant and corrected subcooling to approximately 9 degrees. Discovered blower motor was incorrectly wired with grey wire on cooling tap. Performed static pressure reading (0.6"WC) and rewired to blue wire tap for proper 785 CFM airflow appropriate for 2-ton capacity. Adjustments improved temperature drop from 10 degrees to 15 degrees across evaporator coil. Advised homeowner to monitor system performance and report any continuing issues.
Responded to no cooling call on 2014 residential split system air conditioner. Found compressor operating but condenser fan motor not running. Upon inspection, discovered rodent damage to fan motor wiring. Repaired chewed wire connections and restored proper operation. Due to unit age (10+ years) and overall condition showing weathering and corrosion, provided equipment replacement quote for customer consideration.
Conducted follow-up inspection for reported water leak concerns with visible ceiling stains. Thoroughly examined kitchen sink area including drain lines, water supply lines, and all connections for active leaks or moisture presence. All inspected areas were dry with no signs of recent water exposure. Verified water meter showed no movement indicating no active water consumption or hidden leaks in the system. Physically assessed ceiling stains and surrounding areas, confirming all surfaces were completely dry. Determined that visible ceiling damage, including cracking and floor board curling, resulted from residual effects of previous water intrusion that has since resolved and is in the drying phase. No active leak detected. Sink and plumbing system left in full operational service.
Responded to emergency call from restoration company for active water leak at angle stop valve. Upon arrival, located source of leak at chrome angle stop protruding from bathroom wall. Immediately shut off water supply to stop active leaking and prevent further water damage. Successfully repaired the faulty shut-off valve, restoring proper function and eliminating the leak. Verified repair integrity and confirmed no additional water seepage before completing service.
Responded to no cooling call for dual-system residential property. Upon arrival, found both air conditioning units non-operational with water leaking from indoor coil and severely dirty, restrictive air filters. Removed and replaced filters, then performed thorough cleaning of outdoor condenser coils on both units. Diagnostic testing revealed failing capacitor on one system, which was replaced to restore proper compressor operation. Verified refrigerant charge levels on both systems within manufacturer specifications. Conducted complete system performance evaluation including electrical components, contactors, and control boards—all operating within normal parameters. Provided maintenance recommendations including filter replacement every three months using MERV 8 rated filters to prevent future airflow restrictions and system strain. Both air conditioning systems restored to full operational status with proper cooling capacity confirmed before departure.
Responded to service call and installed thermostatic mixing valve on residential water heater system. Shut off water supply, cut into hot and cold water lines directly above the water heater unit, and integrated new brass mixing valve with proper copper pipe connections and fittings. Adjusted water heater temperature settings to optimal level, pressure-tested all connections for leaks, and verified proper system operation with correct water temperature delivery at fixtures. All work completed with one-year workmanship warranty.
Completed comprehensive AC tune-up on Luxaire system in response to upper floor cooling concerns. Performed thorough inspection of indoor air handler, verifying blower speeds and confirming basement damper was properly closed per homeowner preference. Noted air filter condition requires replacement soon, though homeowner maintains their own replacement schedule. Evaluated airflow at supply vents and confirmed proper cold air delivery throughout system. Identified that upper floor heat retention is primarily attributed to lack of insulation combined with solar heat gain, rather than equipment malfunction. Venting showed adequate airflow with appropriate temperature differential. Conducted complete outdoor condenser unit maintenance including coil rinsing to remove debris and dirt accumulation, cleaned interior of unit, and performed electrical component inspection. Tested and verified capacitor readings within manufacturer specifications, inspected contactor for proper operation and w
Responded to no cooling complaint on 1988 Lennox system with outdoor unit completely silent and unresponsive. Inspected indoor equipment including blower motor speed, air filter, and evaporator coil—all operating normally. Verified contactor engaged at outdoor unit but condenser fan not running. Tested for high voltage at outdoor unit with negative results. Inspected disconnect and discovered two blown 20A fuses. Confirmed fuse failure with ohmmeter testing and replaced both 20A fuses. Restored power and verified system startup with proper operation. Checked refrigeration pressures and temperatures, confirming readings within manufacturer specifications. Performed maintenance cleaning on outdoor condenser coil and rinsed thoroughly. System now operating properly with normal cooling capacity restored.
Completed comprehensive plumbing service addressing multiple fixtures throughout the residence. Repaired leaking outside water spigot by tightening connections and installed new toilet seat mounting bolts to secure loose seat. Replaced reverse osmosis system filters and installed drain plugs for bathroom sink, kitchen sink, and bathtub drain mechanism. Assessed low water pressure issue in tub/shower area and installed new high-quality shower head to improve flow and performance.
Completed comprehensive air conditioning maintenance on single-zone residential system utilizing 410A refrigerant with ambient temperature of 77 degrees. Performed thorough inspection of indoor air handler including filter condition, condensate drain operation, blower motor function, electrical wiring integrity, and all related components with satisfactory findings. Verified proper temperature split across evaporator coil within manufacturer specifications. Conducted complete outdoor condenser unit inspection including coil cleanliness assessment, capacitor testing, and visual examination of all mechanical components. Measured and recorded amperage draw on compressor motor, outdoor fan motor, and contactor to confirm operation within normal parameters. Evaluated refrigerant charge by analyzing system temperatures and pressures, confirming proper charge levels and system performance. All electrical connections, safety controls, and operational components tested and found functioning c
Responded to a water leak originating from the kitchen area with suspected dishwasher involvement. Upon inspection, identified the water inlet valve on the dishwasher as the source of the leak. Shut off the water supply to the dishwasher and disconnected the faulty waterline to prevent further water damage. The existing dishwasher will be replaced by the homeowner with a new unit.
Responded to a water leak emergency in the crawl space where the main water line enters the home. Upon arrival, the water supply was already shut off. Located a pinhole leak in 3/4" copper piping between the main crawl space and equipment room. Removed the damaged section and replaced approximately 3 feet of copper pipe with new material, installing four fittings to complete the repair. Tested the system for proper operation and verified no additional leaks were present before restoring water service to the residence.