We’ve assisted homeowners for over 65 years and will proudly service your home as well.
Minnesota is known for its cold winter weather, and the average high temperatures in Hopkins are well below freezing from December through February. When the cold hits, you can count on our heating experts to make sure your family keeps warm. Our technicians can take care of your furnace, boiler, or heat pump, ensuring it’s correctly maintained and deftly handling any repairs. If you’re struggling with a cold house, we won’t rest until it’s fully warm again. We can also help you enjoy greater comfort by upgrading your house with a new, high-efficiency heating system.
We’re Ready to Assist With Heating Services:
- Heating Repair: Even minor problems can put your heating at risk of giving out suddenly or shortening its lifespan. That’s why you should look to us for prompt heating repairs.
- Heating Installation: Tired of your heating bills rising year after year? Don’t wait until it’s too late! Contact us to get the new system you need.
- Heating Maintenance: Our reliable maintenance services are a great way to save on your energy bills and get the most out of your heating. With the Hurlburt Family Rewards Program, you’ll get discounted repairs and save even more!
Looking for ways to stay cool this summer without breaking the bank? Our service technicians can expertly maintain and repair your AC so it always works efficiently during our often hot and humid weather. We understand how frustrating and stressful it can be when your home is constantly too hot. We offer top-notch ACs, heat pumps, and mini-splits and will help you find the ideal new cooling system for your home.
Depend on Us for These Cooling Services:
- Cooling Repair: If your AC seemingly never shuts off or causes your electricity bill to spike, we can get it fixed straight away. We work on all brands and all types of cooling equipment and can handle any problem.
- Cooling Installation: If you live in an old home without ductwork, a mini-split AC system is the perfect solution to keep you cool. Have an old AC or heat pump that no longer works well? Ditch it and beat the heat with a new central cooling system from Hurlburt.
- Cooling Maintenance: Don’t struggle with frequent breakdowns and subpar energy efficiency. Our maintenance experts will keep your AC in peak condition. Experience the highest level of service and support with the Hurlburt Family Rewards Program!
See all of our HVAC services in Hopkins.
The worst thing you can do when it comes to your plumbing is neglecting issues that need to be fixed. Even a seemingly minor thing like a dripping faucet can cost you greatly due to the amount of water it wastes. No repair is too big or too small for our experienced plumbers to handle. Whether it’s insufficient hot water or a slab leak, we’ll help you overcome it. As one of the most experienced plumbing companies in the area, you can rely on us for professional installations and upgrades as well.
See all of our plumbing services in Hopkins.
Want to make 100% certain your electrical system is safe? Our team can identify any electrical hazards in your home and make sure they’re fully eliminated. Whether it’s smoke coming from an outlet or a switch that feels hot, count on us for rapid, reliable assistance. Upgrading your home with a new electrical panel is a great way to save on electricity costs. We can also keep you prepared for power outages with a backup generator and perform any other installation.
How Our Electricians Can Help You:
- Electrical Repair: We take pride in performing quality electrical repairs and improving electrical safety. From dead outlets and flickering lighting to malfunctioning circuit breakers, we’ll fix whatever problems your home has.
- Electrical Installation: Do you have an EV and are sick of slow charging speeds? Let us help by installing a new Level 2 charging station. We’re adept at installing all other types of electrical equipment and components and are ready to put our skills to work for you.
No matter if your house is near ArtStreet, the Pavilion, or the Artery, we’re ready to serve you. With more than 450 houses that are 100+ years old, Hopkins has a whole lot of historical charm. Whether you live in one of these homes or something newer, we can meet your needs while treating your house with the care and respect it deserves.
For more than 65 years, Hurlburt has been cultivating long-lasting partnerships with area homeowners by offering them honest advice and unbeatable service and support. The thousands of five-star reviews we’ve received are a testament to the quality of work we perform. We also believe in giving back however we can as a way to say thanks to our community.
For assistance from a dependable, trustworthy plumbing, electrical, and HVAC company, contact Hurlburt in Hopkins today!
Responded to recurring water leak near main line with water shut off to home. Located source of hissing noise and identified pinhole leak at soldered 90-degree elbow fitting. Removed failed solder joint and replaced defective 90-degree elbow with new copper fitting using proper soldering techniques. Tested repair for leaks, restored water service, and confirmed system integrity. Customer declined optional replacement of approximately 20 feet of aged piping at this time.
Completed installation of high wind resistant chimney rain cap on existing brick chimney structure. Contacted homeowner prior to arrival to confirm appointment scheduling. Accessed rooftop and removed existing standard metal flue cap from concrete chimney crown. Installed new white metal high wind rated chimney cap designed to prevent water intrusion and withstand severe weather conditions. Secured cap properly to concrete crown ensuring weather-tight seal. Verified proper fitment and stability of new rain cap installation. Inspected brick chimney structure and mortar joints during installation - noted masonry in functional condition with minor weathering and efflorescence present. Documented completed installation with photographs showing before and after conditions of chimney cap replacement. Installation completed within scheduled two-hour timeframe.
Responded to no cool call on 8-year-old Carrier air conditioning system. Upon arrival, discovered the fuses previously installed in the outdoor disconnect were undersized at 15 amps each, causing system failure. Replaced with properly sized 30 amp fuses after verifying compatibility with the 30 amp 2-pole breaker at the indoor panel and confirming maximum fuse rating of 40 amps per manufacturer specifications for the condensing unit. Performed comprehensive system evaluation including amperage readings on all electrical components, condenser coil inspection, refrigerant charge verification, and high voltage circuit inspection. All amp draws measured within manufacturer specifications, condenser coil found clean with adequate airflow, refrigerant charge confirmed at proper levels, and no electrical shorts detected on high voltage circuits. System restored to normal operation with proper cooling performance confirmed before departure.
Performed comprehensive furnace tune-up and safety inspection on 12-year-old Goodman unit. Verified gas pressure and combustion parameters within manufacturer specifications, confirmed safe carbon monoxide levels in flue exhaust. Conducted heat exchanger inspection revealing temperature stress points requiring monitoring. Tested flame sensor and found current reading below 2 micro amps, indicating component failure requiring replacement. All remaining system components tested and operating within acceptable ranges. Submitted parts order for flame sensor replacement and will schedule return visit upon arrival. Recommended upgrading to MERV 7 or 8 rated air filter with monthly replacement schedule for optimal system performance. Unit remains fully operational and safe for continued use.
Completed scheduled maintenance agreement tune-up on furnace and fireplace system with no issues found. Performed comprehensive inspection of HVAC ductwork, noting normal condensation present on metal ducts in attic space, and verified all flexible metal ventilation tubes and connections are properly secured and functioning within normal parameters.
Responded to service call for toilet leak and slow bathroom drain. Upon inspection, identified cracked toilet tank as source of leak. Discussed replacement options and solutions with customer, explaining that tank replacement would be necessary to resolve the leak issue. Assessed bathroom sink drain flow and outdoor hose bibs per customer request for potential shut-off valve installation. Documented conditions with photos showing existing outdoor spigot configuration and bathroom sink plumbing. Prioritized toilet leak repair as immediate concern due to water waste and potential damage.
Completed comprehensive 8-12 point tune-up and inspection on residential air conditioning and furnace system for maintenance agreement member. Identified and replaced weak blower motor capacitor and severely plugged air filter to restore proper system operation and airflow. All equipment tested and confirmed operating within normal parameters upon service completion.
Responded to no cool callback on 10+ year old system following thermostat replacement. Upon arrival, verified thermostat operation and 24V at control board. Inspected outdoor unit and discovered contactor not engaging due to multiple loose low voltage wires. Reconnected all loose wiring to contactor, restoring proper engagement. Tested 35+5 capacitor and found readings below manufacturer specifications. Confirmed system operation with 27-degree temperature split on 2-ton unit with properly configured blower speed. During inspection, identified potential low refrigerant charge on 410A system and noted that both high pressure and low pressure switches had been previously bypassed. Documented safety switch bypass condition and temporarily secured connections. Presented repair estimates for capacitor replacement and refrigerant system evaluation. System restored to operational cooling status with recommendations for future service to address capacitor, refrigerant charge, and pressure swit
Responded to no cool call on 10-year-old air conditioning system with reported complete system failure and no airflow. Upon diagnostic evaluation, determined thermostat had failed and was preventing system operation. Identified failed thermostat as root cause of no cool condition. Customer elected to replace thermostat herself. Scheduled follow-up visit for AC tune-up service once thermostat replacement is completed.
Responded to no-cooling call on residential split system air conditioning unit. Upon arrival, discovered burned fuses in outdoor disconnect with improper 60-amp fuses installed, which exceeded the 30-amp indoor breaker rating. Replaced fuses with correct 30-amp rated fuses to match circuit protection requirements. Installed hard start kit on compressor to improve starting performance and reduce electrical stress. Completed spring tune-up maintenance on both AC systems as scheduled. Thermal imaging conducted to verify proper operation. Unit restored to normal cooling operation with proper electrical protection in place.
Completed comprehensive furnace tune-up and maintenance on a 19-20 year old unit manufactured in 2007. Thoroughly inspected heat exchanger with no cracks detected, confirming structural integrity. Measured carbon monoxide levels at 20 ppm, within safe operating parameters. Inspected blower motor and wheel assembly, both operating properly. Verified control board functionality and all wiring connections in good condition. Flushed condensation pump to ensure proper drainage. Replaced air filter with new unit. Tested and recorded temperature delta-t at 36 degrees, indicating optimal heating performance. System is operating efficiently and prepared for winter season.
Responded to service call for water leaking around gas furnace that had been occurring for three weeks. Upon diagnosis, found evaporator coil freezing up due to low refrigerant levels in the cooling system. Given the age of the unit and extent of refrigerant loss, recommended and completed full system replacement rather than repair to ensure reliable long-term operation and prevent recurring issues.
Completed annual cooling maintenance tune-up on residential air conditioning system. Performed comprehensive inspection and found condenser coil heavily soiled with debris, which was thoroughly cleaned to restore proper airflow and heat transfer efficiency. System operating within normal parameters following service with no additional issues identified.
Completed return visit for previously diagnosed HVAC system failure. Installed new large dual capacitor (35+7.5 MFD) and contactor (up to 3-pole, 50 amp) to replace failed components. Verified proper electrical readings with clamp meter, confirmed system operation, and tested cooling functionality to ensure complete restoration of unit performance.
Responded to a residential plumbing service call for a clogged shower drain backup combined with a biannual plumbing inspection. Upon diagnostic evaluation, determined the tub drain was blocked with an accumulation of hair causing slow drainage and standing water. Cabled the tub drain line using appropriate drain cleaning equipment and successfully extracted a large hair ball obstruction from the drain system. Thoroughly cleaned the tub area and performed water flow testing to verify proper drainage was restored. The drain was flowing freely with no backup at completion. Conducted comprehensive biannual plumbing inspection including examination of water heater, washing machine connections, laundry hoses, and leak detection throughout the accessible plumbing system. During water heater inspection, observed significant corrosion present on the water heater drain valve. Made the decision not to perform standard drain flush procedure due to risk of inducing leaks from the corroded drain
Completed annual cooling maintenance on 6-year-old Daikin central AC system and mini split unit. Central AC inspection confirmed contactor, capacitor, refrigerant charge, and amp draws all within specifications; condenser and evaporator coils clean; temperature drop measured at 20 degrees. Mini split system operating properly with 25-degree temperature drop. Replaced furnace filter during inspection. Critical finding: discovered cracked heat exchanger in 15-year-old furnace; recommended full furnace replacement due to age and safety concerns, with part quote to follow for customer consideration.
Responded to a recall service for a bathroom sink with a malfunctioning drain stopper. Upon inspection, identified that the sink pivot rod assembly had come loose, preventing the pop-up drain mechanism from operating properly. Tightened the retaining nut securing the pivot rod to the drain tailpiece, restoring full functionality to the stopper assembly.
Responded to emergency plumbing service call for burst copper pipe in residential property. Conducted comprehensive assessment of plumbing system, identifying multiple areas requiring repair and replacement including laundry room fixtures, bathroom faucets, and main water shut-off valve. Successfully replaced laundry room faucet with new chrome fixture, restoring full functionality to the washing machine water supply. Addressed the burst copper pipe emergency to prevent further water damage. Documented existing conditions through photography, capturing ceiling-mounted plumbing components and newly installed fixtures. Prepared detailed estimates for remaining work including installation of additional bathroom faucets and replacement of main shut-off valve. Customer approved laundry faucet replacement, which was completed during this visit. Additional repairs scheduled for future appointment pending customer approval of estimates.
Responded to no cooling complaint on three RTU units at commercial facility with approximately 12 total rooftop units. Initial diagnostic visit was shortened due to inclement weather conditions. On Unit 16 serving the welding room, identified one failed compressor that customer elected not to repair, and discovered condenser fan motors inoperative—traced issue to blown fuses requiring replacement on return visit. Confirmed cracked heat exchanger on second unit, which customer has chosen not to repair due to pending lease expiration. Third unit requires additional diagnostics to be completed on scheduled return trip. Documented electrical components and fuse assembly with photos for reference. Return visit needed to install fuses, restore condenser fan operation on Unit 16, and complete diagnostics on remaining non-cooling unit.
Responded to service call for toilet malfunction. Upon inspection, identified faulty flapper causing continuous running and cycling. Replaced deteriorated flapper with new component. Post-installation testing revealed toilet continues to slowly drain and refill approximately every 30 minutes, indicating additional underlying issue requiring further diagnosis. Documented existing Kohler toilet tank components and overall plumbing system configuration including water heater installation for reference.