Replaced 17-year-old 40-gallon LP water heater due to pressure switch failure resulting in no hot water. Installed new Bradford White water heater with proper connections to existing plumbing and gas lines, ensuring proper insulation of copper pipes.
Successfully diagnosed and replaced faulty control board on Richmond furnace. Upon installation of new control board (part #215172-001), tested system operation with positive results. Unit is now heating properly with all functions restored to normal operation.
Responded to no heat complaint on 10+ year old ICP high efficiency furnace. Diagnosed high limit switch tripped due to plugged filter. Reset high limit switch, replaced filter, tested furnace operation, and installed new high limit switch to restore proper heating function.
Responded to call regarding frozen furnace vent pipe. Upon arrival, customer had already cleared ice blockage and furnace was operational. Identified improper venting configuration with approximately 30 ft run under deck causing condensation freezing issues. Consulted with Jordan who scheduled follow-up visit to evaluate alternative venting locations to prevent future freezing incidents.
Responded to no-heat call for Lennox pulse furnace in lockout condition. Diagnosed failed control board and performed pressure test on heat exchanger, which revealed significant leakage. Due to safety concerns, tagged and locked out furnace. Customer is temporarily utilizing electric backup heating while awaiting quote for furnace replacement.
Responded to no-heat call for an 8-year-old furnace exhibiting pressure switch code failure. Diagnosed intermittent power loss to inducer motor despite call for heat at W terminal. Located faulty connection at control board and identified heat exchanger joint leak. Recommended control board replacement and blower wheel cleaning due to significant dirt accumulation affecting system performance.
Responded to customer complaint of unusually high water bill. Upon inspection, identified a leaking toilet flush seal causing continuous water loss. Replaced toilet tank internal components (flush valve assembly and fill valve) to eliminate the leak and restore proper function.
Performed comprehensive furnace tune-up on 5-year-old system per Family Rewards agreement. Conducted full operational inspection, cleaned flame sensor, verified proper condensate drainage, and inspected recently replaced air filter. Checked blower wheel cleanliness and tested all electrical components. During system operation test, adjusted second-stage gas pressure to achieve optimal 55° temperature rise, returning furnace to proper working specifications.
Responded to no heat call for Lennox Pulse 21 LP furnace in lockout condition. Inspection revealed loose hose on pressure switch causing system failure. Reattached hose, cycled power, and confirmed proper ignition sequence. Verified normal thermostat operation and proper fan control cycling. System now operating normally with all components functioning correctly.
Diagnosed 21-year-old natural gas furnace failing to maintain set temperature despite recent filter change. Found plugged condensate line causing pressure switch failure and high limit switch shorting on heat exchanger. Serviced system by cleaning condensation drain line and repositioning high limit switch. System now functioning properly and maintaining desired temperature.
Diagnosed no heat issue on nearly new Olsen oil furnace. Found ice in fuel filter and nozzle assembly due to water contamination in outside fuel tank. Performed complete tune-up including replacement of oil tank filter and nozzle, and flushed fuel lines. System functioning properly after service; customer advised to consider adding isopropyl alcohol to tank to address remaining water contamination.
Successfully replaced gas valve on LP furnace. Unable to adjust gas pressure due to empty LP tank. Customer scheduled for LP delivery, will return after fill to complete pressure calibration.
Responded to no-heat call for Goodman furnace. Diagnostic testing revealed hot surface igniter functioning correctly and gas valve receiving power, but zero gas pressure at inlet/outlet. Resistance testing confirmed failed gas valve, which was replaced to restore proper heating operation.
Diagnosed primary heat exchanger failure in 30+ year old forced air furnace. Furnace was experiencing intermittent blower operation. Upon inspection of internal components and electrical connections, identified cracked heat exchanger which poses carbon monoxide safety risk. Tagged equipment as unsafe for operation and scheduled for replacement estimate.
Performed comprehensive furnace tune-up on a unit that had not been operated for 2 years. Inspection revealed properly functioning system with normal operation. Services included heat exchanger inspection, combustion analysis testing, gas pressure verification (both high and low stage), flame sensor and burner inspection, and blower motor evaluation. Secured condensate tube connection after clearing water buildup. Air filter in moderate condition, pressure switch cleaned. Thermostat confirmed operational with adequate heating performance. No immediate concerns identified.
Successfully installed customer-supplied LP gas water heater (Richmond model) in unfinished basement area. Properly connected black insulated pipes to the top of the unit and positioned the heater adjacent to customer's blue WaterMate tank. Noted presence of mineral deposits on exterior of tank, likely from previous unit.
Performed comprehensive furnace tuneup on 2-year-old LP unit. Cleared condensation drain line and trap of accumulated spiderwebbing and debris. Verified proper operation of inducer motor, pressure switch, control board connections, and thermostat. Combustion analysis showed CO at 13 ppm, within acceptable range. System operating normally with no immediate concerns. Filter in moderate condition.
Performed comprehensive furnace tune-up including clearing condensate drain line and trap of accumulated debris. Inspected heat exchanger which revealed multiple rust eyelids, advised homeowner to install carbon monoxide detector. Verified proper operation of all major components (inducer motor, capacitor, pressure switch, control board connections, thermostat), cleaned flame sensor, and replaced filter.
Responded to no-heat call for a 13-year-old Lennox furnace (Model G61MPV-36B-071-12, SN: 5910J04984). Diagnostic testing revealed failed inducer motor capacitor. Replaced capacitor and confirmed proper system operation, restoring heat functionality with thermostat now properly calling for heat at 70°F setpoint.
Performed semi-annual FRP Furnace Tune Up on 12-42 year-old unit. Tested and confirmed gas train pressure at 9.32 inWC, cleaned condensate drain line and trap to remove debris and spiderwebbing, and verified CO levels at 15 ppm. Inspected and confirmed proper operation of inducer motor, capacitor, pressure switch, control board connections, and thermostat. Replaced moderately soiled return air filter with new one. Furnace is operating within normal parameters with no immediate concerns identified.