Responded to no-cooling complaint on Fujitsu mini-split system. Upon arrival, unit displayed communication error between indoor and outdoor units. Prior to replacing control boards as initially planned, checked refrigerant levels due to history of annual refrigerant additions. Found system completely depressurized with zero pressure. Pressurized system for leak detection and discovered severely loose fitting on outdoor unit. Tightened fitting, evacuated system, and opened service valves to allow factory refrigerant charge to reach indoor unit. Powered up system after refrigerant repair, but unit failed to start with same communication error code. Contacted Fujitsu technical support for diagnostic assistance. Technical support confirmed outdoor unit is designed as multi-zone system requiring minimum of two indoor heads for proper operation. Current installation has only single indoor head, creating incompatibility that prevents system operation and triggers communication faults. Disc
Completed comprehensive air conditioning tuneup as part of recurring maintenance agreement. Tested system operation and confirmed proper cooling with good temperature drop across evaporator coil. Replaced air filter, cleared condensate drain line, performed condenser coil cleaning, and inspected all exterior components. All equipment operating within normal parameters.
Responded to service call for water heater producing excessively hot water. Performed diagnostic inspection of tanked water heater system in basement utility area, examining temperature and pressure relief valve, thermostat settings, and overall unit condition. Assessed aging water heater installation with deteriorating infrastructure including corroded piping and gas shutoff valve. Inspected exterior hose bibb for potential replacement needs. Provided comprehensive estimate for new water heater installation and hose bibb replacement to address safety concerns and prevent scalding water issues.
Responded to a shower valve leak that required the main water supply to be shut off. Upon inspection, identified a faulty cartridge as the source of the leak. Successfully replaced the defective shower cartridge and removed old trim components, restoring proper function to the shower valve assembly.
Responded to maintenance request for two mini-split systems. Upon arrival, determined one unit was a Mr. Cool brand which is outside our service scope. Inspected the second unit, a Fujitsu Airstage mini-split system, which was displaying an indoor capacity fault code indicating communication failure between the indoor and outdoor units due to perceived size mismatch. Performed comprehensive diagnostic testing of all system components and verified proper voltage levels at both indoor and outdoor units. All electrical components tested within normal parameters, isolating the issue to a faulty control board. Consulted with homeowner regarding findings and recommended control board replacement. Submitted parts request to obtain pricing and availability for replacement control board. Unit was left in off position pending parts arrival and authorization for repair. Subsequently returned to site and successfully replaced the defective control board, restoring full system functionality and com
Responded to commercial facility for failed water heater with active leak. Removed existing defective unit and installed new 100-gallon commercial-grade tanked water heater. Completed all copper piping connections with proper soldering techniques, installed brass ball valves for system isolation, and integrated PVC venting per manufacturer specifications. Connected hot and cold water supply lines, installed expansion tank, and verified all connections for leaks. Mounted temperature and pressure relief valve with appropriate discharge piping. System tested, pressurized, and confirmed operational with no leaks detected.
Responded to kitchen plumbing issues involving water leak beneath sink and slow drainage. Removed and replaced deteriorated kitchen faucet with new Moen unit to eliminate leak source. Addressed drainage problem by running mechanical drain snake through kitchen sink drain line to clear blockage and restore proper flow. All plumbing connections tested and verified leak-free upon completion.
Responded to no heat call on 1994 Lennox propane furnace. Upon arrival, found pilot would ignite but main burner would not light, with igniter sparking continuously for approximately 30 seconds before system shutdown. Removed pilot assembly and thoroughly cleaned spark rod, flame sensor, and verified pilot tube was clear of obstructions. Reinstalled pilot assembly and tested system operation—unit now igniting properly and heating as designed. Performed visual inspection of heat exchanger with no condemnable cracks observed.
Installed customer-supplied Moen tub and shower valve assembly at the residence. Arrived on-site during the scheduled window, contacted customer prior to arrival as requested, and successfully completed the installation of the new valve system.
Responded to water leak emergency in basement originating from shower area. Upon arrival, water supply to home was shut off due to broken Delta valve in wall, damaged during attempted self-repair. Installed temporary shut-off valves to restore water service to remainder of home while isolating the compromised shower fixture. Follow-up appointment scheduled pending estimate approval for complete valve replacement and permanent repair.
Responded to emergency call for leaking 50-gallon electric water heater with water discharge from bottom of tank. Upon arrival, shut off water supply and drained the unit to prevent further water damage. Inspection confirmed failed tank integrity requiring full replacement. Removed existing failed water heater and installed new 50-gallon electric Bradford White water heater, reconnected all electrical and plumbing connections, and tested unit for proper operation.
Responded to water leak complaint under kitchen sink at residential property. Upon inspection, identified garbage disposal as source of leak. Removed failed garbage disposal unit and installed new sink basket strainer assembly in double-basin stainless steel sink. Verified all drain connections were properly sealed and tested system for leaks. No further water intrusion detected upon completion.
Performed inspection of residential plumbing system to verify pipe sizing, confirming 1-1/2" L copper piping installation. Documented existing HVAC and plumbing configuration including ball valve connections, PVC supply lines, and mechanical equipment layout. Provided consultation regarding electronic anode rod installation options for water heater system.
Replaced exterior hose bibb that was plumbed through crawl space, installing new frost-free spigot in recessed wall box with proper mounting to exterior siding. Rebuilt second hose bibb located at kitchen side of home, replacing worn valve assembly and ensuring proper shutoff function. Replaced hose bibb under kitchen sink, integrating new valve with existing water filtration system and supply lines while maintaining proper connections to copper supply pipes and PVC drain assembly.
Completed annual air conditioning tuneup and preventative maintenance inspection per service agreement. Performed comprehensive system evaluation including visual inspection of air handler, motor assembly, ductwork, and electrical connections. All components found operating within normal parameters with no deficiencies noted. Refrigerant charge assessment deferred due to ambient temperature conditions being too low for accurate readings; system not requiring refrigerant service at this time. Unit confirmed operational and ready for cooling season.
Completed annual cross-control backflow prevention inspection and testing on two devices: a Wilkins 975XL RPZ valve (serial number ABB08849) located in Washroom #2 and a Wilkins 460XL SVB valve (serial number 461483) located at the freezer wall. Both assemblies passed testing with acceptable differential pressure readings recorded for check valves and relief valve components. Additionally, replaced a malfunctioning foot-activated mixing valve at the hand wash sink to restore proper operation.
Responded to commercial customer complaint of low water pressure affecting dishwasher operation. Diagnosed faulty solenoid valve as the root cause of insufficient water flow. Ordered replacement cleanout cover to address broken component and submitted part order form per management instruction.
Installed new single compartment sink and wall mount sink with faucet in janitor's closet area. Ran water lines overhead with insulated PEX piping and connected drain to open site adjacent to sink. Capped existing shutoff (CR19) with PEX plugs as requested.
Conducted comprehensive inspection of toilet reported for leaking issues. Identified significant mineral buildup and aging components within the tank, including worn flush valve and deteriorated flapper mechanism. Provided on-site assessment and repair options to resolve the water leakage problem.
Responded to no-heat call for newly installed furnace. Diagnosed shorted limit switch as the source of the heating failure and non-functional thermostat. Implemented temporary repair to restore heat safely until permanent replacement can be performed.