Completed comprehensive tune-up on both furnace and air conditioning system. Inspected all routine furnace components including heat exchanger, gas pressures, and flue passages—all found within manufacturer specifications. Furnace operated properly with approximately 50-degree temperature drop across heat exchanger. On the air conditioning side, discovered heavily plugged condenser coil restricting airflow and completely blocked evaporator drain line that had been causing water leakage. Cleared evaporator drain line to restore proper condensate drainage. AC unit achieved approximately 20-degree temperature drop during extended operational test, though refrigerant charge appears low on R22 system. Both systems ran for 10-15 minutes to verify proper operation under load. Documented findings with photos showing blower assembly with heat damage indicators and HVAC testing equipment setup used for system diagnostics. Provided estimates for recommended repairs including condenser coil cle
Performed comprehensive maintenance on both furnace and air conditioning systems. Inspected all routine components on the furnace, verifying cleanliness and proper operation within manufacturer specifications. Examined heat exchanger with no compromises detected. Conducted full inspection of AC system components, all measuring within acceptable parameters. Cleaned Lennox outdoor condenser unit. Executed extended operational testing of both systems for 10-15 minutes each. Furnace demonstrated proper gas pressures with 55-degree temperature rise across heat exchanger. Air conditioning system achieved approximately 20-degree temperature split, confirming adequate cooling capacity. All electrical components, capacitor, and contactors functioning properly. Both systems operating as designed with no deficiencies noted.
Responded to no cooling call and found approximately 50-year-old outdoor condensing unit with severely damaged electrical wiring feeding the equipment, with exposed bare conductors creating an unsafe condition that prevented system operation. Checked refrigerant static pressure at 120 psi, which does not confirm adequate charge without system running. Advised customer of immediate electrical hazard requiring licensed electrician to install new disconnect box and supply wiring before unit can be safely energized and further diagnosed. Documented equipment condition with photos and coordinated comfort advisor visit for replacement evaluation given age and condition of system.
Diagnosed failed compressor on XC16 air conditioning unit and performed complete compressor changeout. Removed defective compressor, installed replacement unit, evacuated and recharged refrigerant system to manufacturer specifications, and verified proper operation of all components.
Responded to no cooling call where breaker had tripped and unit would not restart after reset. Performed diagnostic testing and confirmed compressor failure with short to ground condition. Documented findings with photos showing system components and overall unit condition. Submitted parts request for compressor replacement to proceed with necessary repairs.
Completed warranty replacement of geothermal system blower motor. Retrieved motor from designated location, installed new unit, and verified proper operation of all system components. System tested and confirmed functioning within normal parameters.
Responded to no-cooling complaint on 3-month-old installation that was unable to maintain 70°F setpoint during hot weather. Diagnosed low subcooling and high superheat, indicating refrigerant overcharge. Recovered approximately one pound of R-454B refrigerant and replaced heavily restricted air filter. Verified system operation and proper refrigerant charge levels, though ambient temperature of 63°F prevented full load testing under design conditions.
Responded to service call for non-operational geothermal system. Diagnosed faulty blower motor that was receiving electrical power but failing to operate. Submitted parts request for replacement blower motor and control module required to restore system functionality.
Responded to service call for heating system failure. Diagnosed faulty hot surface ignitor preventing equipment ignition. Removed failed ignitor assembly and installed new replacement unit. Tested system operation, verified proper ignition sequence, and confirmed equipment fired successfully with stable flame. System restored to full operational status.
Responded to no heat call on 10+ year old Temp Star furnace with smart valve ignition system. Diagnosed failed hot surface igniter - confirmed voltage present at igniter but unit would not glow, resistance testing showed megaohms indicating open circuit. During inspection, identified minor leakage on secondary heat exchanger and documented condition with photos. Replaced faulty hot surface igniter and tested system operation to restore heating functionality.
Installed hot water mixing valve on existing copper piping system to regulate water temperature and prevent scalding at fixtures. The mixing valve was integrated into the U-shaped copper pipe configuration in the mechanical room, connecting to the hot and cold water supply lines with proper fittings and joints. Installation ensures safe delivery of tempered water at appropriate temperatures throughout the distribution system.
Responded to no hot water complaint on A.O. Smith tanked water heater installation. Upon inspection, diagnosed failing mixing valve as cause of hot water delivery issue. Provided estimate for mixing valve replacement to restore proper hot water function to the system.
Completed comprehensive plumbing inspection of residential bathroom fixtures. Examined sink assembly, faucet operation, drainage system, and toilet tank components including flapper valve, fill valve assembly, and refill tube for proper functionality and potential issues.
Completed Family Rewards cooling maintenance visit on Lennox AC system. Performed tune-up service and cleaned outdoor unit coils. Due to ambient temperature of 34°F, full system performance testing was limited; however, unit demonstrated cooling capability during available testing parameters. Advised customer to contact for service if any issues arise when warmer weather permits full system evaluation.
Responded to no heat call on unit 10+ years old. Found combustion blower running continuously without call for heat due to stuck relay on control board. Tested relay by tapping board, which restored normal operation temporarily. Advised customer that control board replacement would likely be needed and submitted parts request form for future ordering, but customer elected to monitor system performance before proceeding with repair.
Responded to no heat call on 11-year-old LP furnace that was attempting to ignite but immediately shutting down. Diagnosed faulty gas valve causing system shutdown during heating cycle—verified pressure switches were functioning properly, system was pulling adequate vacuum, and 24V power was present at gas valve terminals. When gas valve wiring was disconnected, control board operated normally and supplied proper voltage, confirming gas valve failure. Replaced defective gas valve to restore heating operation. Unable to complete full burner and heat exchanger inspection due to equipment limitations; recommended follow-up visit for comprehensive internal component evaluation given unit age and condition of other components before providing estimate for additional repairs.
Responded to follow-up call regarding dripping noise in laundry room after previous burst pipe repair. Upon inspection, identified two sources of water leakage: a loose washing machine supply hose connection and a cracked slip nut on the laundry tub drain assembly. Tightened the washing machine hose to proper torque specifications to eliminate leak at connection point. Replaced the damaged slip nut and deteriorated tee gasket on the laundry tub drain system with new components to restore proper seal and prevent further water intrusion. Verified all connections were secure and leak-free before restoring water supply to the home.
Responded to follow-up call for previously serviced heat pump not working. Upon arrival, system was operational but inspection revealed completely clogged filter with ultrasonic humidifier dust; removed filter which improved system performance. Noted significant rust and corrosion on burners (documented with photos) and recommended replacement of these components in the near future.
Diagnosed no-heat issue on 8-12 LP Furnace (10+ years old) and identified thermostat communication failure. Tested wiring connections and installed customer-supplied replacement thermostat. Verified proper system operation and confirmed heat restoration.
Diagnosed heat pump and furnace synchronization issue where both systems were attempting to run simultaneously. Found heat pump providing insufficient temperature rise (only 15-20°F) before defaulting to furnace operation. Adjusted thermostat balance point from 20°F to 35°F to improve system coordination and recommended follow-up service with heat pump specialist for further evaluation.