Our HVAC technicians are highly trained and experienced in order to bring you the best in repair, installation and maintenance services.
We also specialize in plumbing services to meet your repair, inspection and installation needs. We offer 24/7 services to ensure that your emergency heating, cooling or plumbing repair can be addressed right away!
Hurlburt Heating & Plumbing has completed 20 jobs in Arkansaw, WI between July 2026 and September 2026.
The most recent job was on September 8, 2026.
Hurlburt Heating & Plumbing has completed 84 jobs in Arkansaw, WI in the last 12 months. The first job there was in October 2015.
Completed installation of bathroom and utility sink fixtures during scheduled service call. Set and secured brushed nickel three-piece faucet assembly with dual lever handles and central spout on undermount white basin, ensuring proper alignment and water flow. All fixtures tested for leaks and functionality upon completion.
Responded to service call for furnace with leaking inducer motor covered under parts and labor warranty. Removed and replaced the defective original inducer motor assembly with new warranty replacement unit. Upon completion of installation, performed comprehensive system testing including furnace operation verification and complete venting system inspection. All components functioned properly with no issues detected. Unit restored to full operational status.
Performed comprehensive furnace tune-up on Lennox unit, including cleaning flame sensor, verifying condensate drainage, and measuring gas pressure at 4.5" low fire and 9.58" high fire with all systems operating within specifications. Inspected black flexible ductwork in attic space where customer reported bee infiltration and nest buildup; assessed damage and submitted parts request for approximately one-hour flex duct replacement. Coordinated with homeowner via phone to complete service and provided information regarding available membership programs.
Completed comprehensive plumbing inspection of residential property including attic crawl space and basement utility areas. Examined all visible plumbing systems, PVC drainage lines, water supply piping, and verified proper installation and functionality of plumbing infrastructure throughout inspected zones.
Responded to service call for leaking well pressure tank in basement. Upon inspection, confirmed pressure tank failure with active leak. Removed existing failed pressure tank and outdated galvanized tee assembly. Installed new 20-gallon well pressure tank with new tee assembly to restore proper water system function and prevent potential pump motor damage. Set pressure to 38 PSI per system specifications. Removed all galvanized fittings during installation. System tested and operational upon completion.
Responded to service call for leaking pressure tank in basement utility area. Upon inspection, confirmed active leak from aging blue pressure tank showing significant deterioration, surface corrosion, and wear. Water staining and rust-colored marks visible on concrete floor beneath equipment, indicating ongoing moisture exposure. Pressure tank exhibited compromised integrity requiring full replacement. Documented existing conditions including tank specifications, current pressure readings from mounted gauge, and plumbing connections to water softener and water heater systems. Photographed deteriorated tank exterior, tank tee assembly, and associated piping infrastructure. Submitted part order form to obtain estimate for new pressure tank and tank tee assembly replacement. Customer advised that water supply did not require emergency shutoff at time of inspection.
Completed comprehensive furnace maintenance and tune-up on 8-year-old Lennox heating unit as part of recurring Family Rewards membership service. Performed thorough inspection of furnace components, verified proper operation of all systems, and confirmed no immediate concerns or safety issues were present at time of service.
Performed comprehensive tune-up service on two air conditioning systems. Inspected both air handlers and cleared condensate drain lines. Addressed significant water accumulation on mechanical room floor by thoroughly flushing and clearing the condensate drain system on the unit in the mechanical room. Drain flow improved after flushing but continues to show slow drainage characteristics. Washed both condenser units and performed full system diagnostics. Tested all capacitors and electrical components. Found capacitor on the older system reading 42.2 mfd against a rated 45 mfd specification, which remains within acceptable operating tolerance. Measured temperature drop across both systems at 29°, which is normal for high-velocity applications. Due to the high-static, high-velocity system design, recommend using minimal-restriction air filters to reduce moisture accumulation at the coil. This drainage issue appears to be a long-standing characteristic of the system design rather than a
Responded to service call to inspect gas system and plumbing connections. Conducted thorough gas leak testing throughout the property with negative results. Identified and corrected exposed metal on gastite fitting to ensure proper installation standards. Re-tested all gas connections after repair to verify system integrity. In basement utility area, reconnected water supply pipes running beneath toe kick space that had become disconnected. All plumbing connections secured and tested for proper operation.
Responded to callback for gas and water leaks identified during previous installation at school facility. Repaired gas leak at TRAC fitting near furnace by replacing section of gas piping and pressure testing for integrity. Addressed water leak on newly installed water softener by replacing defective bypass valve assembly. Modified existing plumbing lines in basement where commercial dishwasher was previously located, cutting pipes lower to accommodate toe kick clearance requirements and properly capping all openings. All systems tested and verified operational with no leaks detected upon completion.
Completed comprehensive tune-up service on both air conditioning and gas furnace systems. Resolved water issue around furnace by clearing plugged condensate line and removing deceased mouse from drain pan, restoring proper drainage. Performed full inspection of A/C system including refrigerant check, component operation verification, and confirmed proper 20° temperature drop across evaporator coil. On gas furnace, cleaned burners and flame sensor, cleared condensate system, and performed video scope inspection of heat exchanger with no defects found. Verified safe operation of all components on both systems. All equipment now operating within manufacturer specifications.
Completed comprehensive tune-up maintenance on both 9-year-old furnace and air conditioning systems as part of membership agreement. Performed full system inspections and discovered critical issues requiring attention: inducer motor mounting screw had corroded completely, causing water leakage throughout upper furnace cabinet, and condenser fan motor was operating in reverse due to incorrectly wired capacitor connections. Cleaned condenser coil and corrected all accessible components to manufacturer specifications. Conducted operational testing of both heating and cooling systems with 15-minute run cycles to verify proper function. All systems operated correctly following maintenance procedures, and property owner was contacted with findings and provided estimate for inducer motor replacement.
Performed comprehensive air conditioning tune-up on 20-year-old Goodman system. Verified system operation with temperature differential measuring 18-19°F across the evaporator coil. Tested capacitor functionality and confirmed proper operation. Recorded suction pressure at 75 PSI under 90°F ambient conditions, indicating adequate refrigerant charge. Thoroughly cleaned condenser coil which had accumulated significant debris affecting heat transfer efficiency. Recommended pre-season furnace inspection due to age of equipment before heating season begins.
Responded to no cooling complaint on 7-year-old Lennox system. Upon inspection, discovered rodent damage to compressor wiring harness. Replaced damaged harness with compatible unit from inventory and restored electrical connections to compressor. Sealed penetrations around line set with silicone to prevent future rodent entry. Removed and discarded damaged compressor jacket. Cleared inverter alarm codes from system. Verified proper system operation and cooling restored to residence.
Responded to no cooling complaint and furnace fan continuously running. Diagnosed and replaced faulty thermostat, restoring proper system operation and resolving continuous fan issue. Investigated reported oil leak at filter location following previous maintenance visit. Inspected oil filter assembly and cleaned surrounding areas. Filter and gasket appeared secure with no active leaking observed. Identified loose fitting at bottom of oil tank as potential leak source. Advised customer that tank fitting requires attention from fuel company as it falls outside HVAC scope of work. Verified system cycling properly with new thermostat installed. All HVAC components functioning as designed upon completion.
Responded to no cooling complaint on 25-year-old Gibson outdoor condensing unit. Diagnosed failed run capacitor preventing compressor and fan motor operation. Replaced defective capacitor with proper replacement, restored system to normal operation, and verified cooling performance.
Responded to water heater leak on hot side outlet piping with multiple fitting failures. Replaced all hot and cold side piping and fittings above the water heater unit to eliminate leaks. Restored main water shut-off valve to operational position upon completion of repairs.
Completed water line rough-in installation for shower valve with PVC piping and mounting brackets secured to wall framing. Installed well pump control box and rewired pressure switch connections, verifying electrical power supply to system. Upon testing, pump failed to operate despite confirmed power delivery; recommended specialist well service contractor for pump diagnostics and repair to resolve operational issue.
Responded to service call for AC unit not cooling properly and leaking condensation into furnace. Upon inspection, found minor condensate drain blockage which was cleared. Evaporator coil showed signs of freezing despite being relatively clean with adequate airflow. Measured system pressures and found suction pressure at 58 PSI, approximately 12 PSI below optimal specification for R22 refrigerant, indicating significant refrigerant loss. Inspected 30-year-old outdoor condenser unit and noted heavy dirt accumulation on coil fins. Made decision not to clean condenser coil due to concern that improved heat transfer would further drop suction pressure and result in complete system failure. Given the age of equipment (33-year-old furnace, 30-year-old AC unit), low refrigerant charge, and overall system condition, recommended system replacement consultation. Unit left operational with reduced cooling capacity pending replacement evaluation.
Responded to warranty callback for reported gas leak near tankless water heater. Identified leak at corrugated gas piping connection and loose union on water softener. Removed defective section of corrugated gas line, reassembled piping, and tightened water softener union to eliminate both leaks. Performed comprehensive leak detection test on all gas fittings and plumbing connections in area to verify system integrity.