Responded to a no-heat complaint on an approximately 20-year-old electric boiler. Upon arrival, the system was idle with warm piping, as the thermostat setpoint was already satisfied. Raising the setpoint to 65°F called for heat, the circulator pump energized, and the boiler produced heat normally, confirming proper operation; no repairs were required and the visit was completed as a diagnostic only.
Diagnosed a no-heat condition on an LP furnace that would not ignite or sustain a flame, and traced it to a flame sensor failing to detect flame. Removed and cleaned the flame sensor, then performed a full system inspection, including the heat exchanger, which showed no defects. Identified a restrictive, low-grade furnace filter as the cause of the limit switch tripping and recommended replacing it with a higher-quality filter; furnace restored to normal operation.
Performed no-heat diagnostic and maintenance on the residential furnace and the shop tube heater. On the tube heater, found a failed igniter and an intermittent pressure switch that would not reliably close; with the switch bypassed, verified proper draft through the vent to the roof termination, which was clear of obstructions though showing early corrosion. Unit lit but dropped flame after several seconds, indicating a probable flame-sensing or control board fault. Replacement of the igniter, pressure switch, and control is recommended, though parts availability for this 20+ year-old unit may be limited.
Installed a thermostatic mixing valve on the outlet of the electric tank water heater to temper hot water delivery and reduce scald risk. Sweat-soldered new copper piping and fittings, including shutoff valves, to integrate the valve into the supply plumbing, and verified the connections were clean, secure, and leak-free.
Diagnosed a no-heat condition caused by a condensate drain blockage that allowed water to accumulate in the inducer motor. Cleared the condensate drain tubing and trap of ladybug debris, then removed the burner box to clean insects out of the burners. Restarted the system and verified normal heating operation, and recommended annual pre-season maintenance to prevent future insect-related issues.
Diagnosed an oil furnace that cycled on briefly, shut down, and failed to reach temperature, with the blower not starting during operation. Found the fan center relay faulty and sticking, restored blower operation, and identified a sticking fan limit switch that does not shut off properly. Provided estimates for replacement of the relay and fan switch, and the homeowner is scheduling a consultation for an oil-to-gas conversion.
Completed comprehensive maintenance tune-up on Lennox furnace system under rewards plan agreement. Performed thorough cleaning of routine components including burner assembly, verified proper gas combustion with uniform blue flame pattern across all burners, and inspected gas valve assembly and connections. Tested all equipment operations, confirmed proper function of heat exchanger, verified condensate drain lines and PVC venting system integrity, and inspected refrigerant lines and electrical connections to ensure system is operating safely and efficiently for the heating season.
Completed comprehensive tune-up service on 3-year-old residential HVAC system including outdoor air conditioning unit and gas furnace. Performed standard maintenance procedures per manufacturer specifications, inspecting all mechanical and electrical components, checking refrigerant levels, cleaning condenser coils, testing system operation, and verifying proper airflow. Unit is operating within normal parameters with no issues identified at this time.
Replaced single-stage control board on Lennox furnace that was previously diagnosed during winter service call. Performed complete furnace tune-up and preventative maintenance as part of rewards membership service, including system inspection and operational testing. Verified proper furnace operation and confirmed all systems functioning correctly upon completion.
Replaced defective furnace control board under parts warranty. Installed new warranty control board, verified heating operation, and briefly tested cooling system (limited run time due to 50° outdoor temperature). System operational upon completion.
Responded to service call for leaking water heater. Upon inspection, confirmed active leak from existing tank-style water heater requiring immediate replacement. Removed and disposed of failed unit, then installed new A.O. Smith ProMax tank water heater in basement utility area. Connected all supply and discharge lines including PEX and copper piping, installed appropriate shut-off valves, and verified proper temperature and pressure relief valve operation. System tested and confirmed operational with no leaks detected.
Completed scheduled heating maintenance on 8-year-old Lennox furnace as part of membership agreement. Performed comprehensive tune-up inspection and identified non-functional humidifier requiring replacement. Installed new humidifier unit and condensation pump with proper PVC drainage configuration. Noted requirement for GFI outlet installation to meet current electrical code standards for condensate pump operation. All components tested and verified operational upon completion.
Completed Family Rewards furnace tune-up on Lennox heating system with no customer concerns reported upon arrival. Performed comprehensive furnace maintenance per standard tuneup protocol, verified air filter was clean and left replacement filter on-site. Inspected and serviced additional garage-mounted heating unit per customer request, performing routine component checks on both systems. Tested primary furnace operation for 15 minutes, confirming proper performance with 55° temperature rise at maximum heating rate. Tested garage unit operation for 10 minutes, verifying all components functioned correctly. All systems operating within normal parameters with no deficiencies identified.
Provided customer education regarding maintenance schedule for VIQUA point-of-entry water filtration system previously installed alongside water softener. Advised on recommended filter replacement intervals and offered filter replacement service, which customer declined at this time.
Responded to no heat call on 10-15 year old furnace where blower was operating but unit failed to produce heat. Upon inspection, discovered completely plugged air filter and failed control board. Evidence suggests AC condensate overflow migrated to control board causing electrical failure. Submitted parts request for replacement control board with customer callback required for pricing approval.
Replaced deteriorated intake flex duct and installed protective mesh screen at exterior vent opening. Verified proper operation of fan and damper system, confirming adequate fresh air intake and normal functionality upon completion.
Completed installation of reverse osmosis water filtration system per approved estimate. The system is designed to remove common chemical contaminants including metal ions, aqueous salts, sodium, chloride, copper, chromium, lead, arsenic, fluoride, radium, sulfate, calcium, magnesium, potassium, nitrates, and phosphorous. All components installed and operational, with photographic documentation taken of completed work.
Responded to service call for non-functioning A.O. Smith ProLine 50-gallon electric water heater that was originally installed by our company four years prior. Upon arrival, determined that the unit was not operational due to homeowner's unfamiliarity with the peak time control box, which restricts water heater operation during high-demand electrical periods. Educated the new homeowners on the function and operation of the peak time control system. During inspection, identified a faulty temperature pressure relief valve that required replacement. Replaced the defective T&P relief valve with a new unit, covering the part under manufacturer warranty. Verified proper operation of the water heater system and confirmed adequate hot water production following repairs.
Completed comprehensive annual furnace tune-up and inspection on 12-year-old heating system per maintenance agreement protocol. Performed standard preventative maintenance checklist including burner inspection, heat exchanger examination, blower motor assessment, filter evaluation, and verification of proper venting through PVC intake and exhaust pipes. All components found operating within manufacturer specifications with no deficiencies noted at time of service.
Responded to main sewer line backup causing drainage issues in the basement. Upon inspection, found significant accumulation of debris and gunk in the sewer pipe, likely caused by root intrusion from a previously removed tree. Utilized medium rigid cable machine to thoroughly clean and clear the main sewer line. Additionally cleared and cleaned the kitchen sink drain to restore proper drainage throughout the system.