We’ve assisted homeowners for over 65 years and will proudly service your home as well.
with Purchase of Furnace & AC
Includes Merv 16 5" media cabinent and ApcoX Premium UV-light. Cannot be combined with any other offers. Must present coupon at time of service. Not valid on previously completed work.
A heating system that works properly keeps your home safe and comfortable throughout the frigid winter months. We can fix, install, or maintain a furnace or heat pump to ensure that each room in your house is consistently comfortable. We work uniformly and efficiently at all times, taking care to clean up after ourselves and leave your home as tidy as we found it.
Count On Us for These Professional Heating Services:
- Heating Repair: A malfunctioning furnace or heat pump can lead to gas leaks, frozen pipes, or other serious issues. Our team will make timely heating repairs to ensure that your home remains cozy throughout the long, cold winter.
- Heating Installation: A new furnace is typically more efficient and easier to operate than an older model. In addition, you may qualify for tax credits or other incentives to keep current and future costs to a minimum.
- Heating Maintenance: Ideally, you’ll have your furnace serviced and cleaned once or twice a year. The Hurlburt Family Rewards Program can make it easier to get the service you need in a convenient and timely manner.
Ensure your home in St. Paul is a cool, comfortable respite during the hotter months. The late spring, summer, and early fall months tend to be warm and humid. We can fix, install, or maintain your cooling system to ensure that a clogged condensate line or broken fan blade won’t cause you to overheat while at home.
We’re Happy to Provide These Cooling System Solutions:
- Cooling Repair: It’s no sweat for our team to diagnose and fix any type of issue that might befall your air conditioning system. If your system is still under warranty, it may cover some or all of the cost of needed repairs.
- Cooling Installation: Modern cooling systems offer a number of options, such as zoned cooling, cooling schedules, and smart tools. This may help you keep cooling bills to a minimum while ensuring everyone can stay comfortable indoors when it’s uncomfortably warm outside.
- Cooling Maintenance: When we maintain your cooling system, we can help catch small issues before they spiral out of control. You can also minimize the risk of voiding a warranty or otherwise spending money on repairs that could have been avoided. Our Hurlburt Family Rewards Program makes it easy to get the service that you need.
- Indoor Air Quality
A cracked pipe or a leak can cause damage to walls, insulation, or other items in your home. We can diagnose and fix these and other issues to ensure that all your plumbing pipes and fixtures function properly. When done correctly, upgrading your home’s plumbing may increase its value as well.
Count on our expert electricians! From EV charger installation to new electrical panels, we do it all. You can count on us to repair wiring, lights, and switches as well as replace and install it all.
We’ll Gladly Assist You With These Electrical Services:
- Electrical Repair: Flickering lights, a hot dimmer switch, or exposed wires can be signs of serious issues that can’t be left unchecked. An electrician will diagnose the cause of your electrical problem and fix it with materials that are durable and adhere to local codes.
- Electrical Installation: We will install new switches, wires, or other items in a timely and safe manner. This ensures that you can use your washer, stove, and computer at the same time without worrying.
Whether we’re repairing heating systems near Como Park or installing new cooling systems on homes near St. Thomas University, we’re proud to serve the community however we can. We’ll also be happy to help install a new EV charger on your Summit Avenue home or repair a leaky pipe on your property close to where the old Ford assembly plant was located.
Our team of professionals will provide a variety of plumbing, electrical, and HVAC services in a timely and affordable manner. We will treat your home just like we would our own, which means that you’ll get great service from the moment you call us to the moment we finish your project. Before work begins, we’ll give you a comprehensive explanation of what we need to do and how much it will cost and let you decide how you want to proceed. Welcome to the Hurlburt Family!
When you need help from a plumbing, electrical, and HVAC company in St. Paul, give the team at Hurlburt a call today!
Responded to no cooling complaint following recent power surge and outage. Upon arrival, both AC systems were operational after breaker reset, but full diagnostic inspection was requested. Tested dual run capacitor on first unit (right side) and found complete failure, reading 0/4.3 MFD versus rated 40/5 MFD. Compressor was only able to start with assistance from existing hard start kit due to failed capacitor. Replaced failed dual run capacitor and verified normal system operation restored. Inspected second AC unit and found all major components functioning properly. Removed rodent nest from second unit. Verified refrigerant operation on both systems operating within normal parameters. Measured and confirmed supply and return air temperatures on both units within acceptable range. Noted humidifier solenoid stuck in open position requiring future service if correction desired. Both AC systems left operating normally with proper cooling restored.
Completed warranty thermostat replacement on HVAC system. Removed old thermostat and installed new unit per manufacturer specifications, connecting all wiring to appropriate terminals on the control board. During installation, identified that the circuit board lacks an O/B terminal, requiring thermostat configuration to be set for conventional heating mode rather than heat pump operation. Verified all electrical connections at terminal blocks, programmed thermostat settings accordingly, and performed operational testing to confirm proper system function.
Completed preventive maintenance service on one rooftop air conditioning unit utilizing R-410A refrigerant with ambient temperature at 78 degrees. Performed comprehensive inspection of all system components including air filter, thermostat operation, temperature differential, condenser unit, evaporator and condenser coils, blower and condenser motors, run and start capacitors, compressor operation, refrigerant charge levels, and condensate drain line. Verified equipment mounts and structural supports per customer request. All components tested within normal operating parameters and system is functioning properly at time of service completion.
Responded to laundry drain backup causing standpipe overflow when washing machine discharged. Diagnosed blockage at point where drain enters ground, determined to be residual toilet paper from previous mainline obstruction. Cut drain line apart and extracted large accumulation of toilet paper debris. Cabled drain line to clear remaining blockage and restore proper flow. Installed repair band on laundry drain pipe to secure connection. Performed flow test by running water through system for approximately five minutes with no backup observed, confirming drain line fully opened and functioning properly.
Responded to service call for outdoor hose bib concerns following recent repipe work completed in December. Upon arrival, assessed the exterior spigot and determined that an extension hose installation was required to address the operational issues. Successfully installed hose bib extension to resolve the functionality concerns and restore proper outdoor water access.
Responded to no cooling concern on Mitsubishi mini-split system. Performed comprehensive inspection of all indoor air handlers and entire refrigerant line set after customer reported bluish discoloration and moisture on gas line insulation near condenser connections. Conducted thorough leak detection testing throughout system with no refrigerant leaks identified. Determined that observed oxidation and corrosion on line set copper piping is normal surface oxidation resulting from condensation and sweating during system operation. Inspected air filters which showed moderate dust accumulation but remain serviceable. System operating within normal parameters with no refrigerant loss or mechanical deficiencies found.
Completed phone follow-up to update existing estimate by adding furnace to previously quoted air conditioning system. Inspected and photographed basement mechanical area containing existing HVAC equipment and water heater to prepare comprehensive bid for furnace installation. Customer expressed enthusiasm about proceeding with both furnace and AC replacement and requested information on current promotional offers.
Responded to a disconnected kitchen sink drain where the P-trap was not properly connected to the drainage system. Successfully installed and secured the P-trap assembly, establishing proper connection between the sink drain and the main drain line to restore full functionality and prevent water leakage.
Completed comprehensive heat pump tune-up and maintenance inspection per agreement with no reported issues. Performed thorough system evaluation including thermostat operation, air filter assessment, blower assembly inspection, outdoor coil examination, electrical component testing, contactor inspection, condensate drain verification, refrigerant performance analysis, and temperature split measurements. All operational parameters and readings confirmed within manufacturer specifications with no mechanical defects or safety concerns identified. System verified operating efficiently and properly. Documented equipment condition with photos showing outdoor unit louvers and internal components including refrigerant lines, electrical connections, and cabinet interior. Advised customer to maintain regular filter changes, keep indoor and outdoor coils clean, and continue scheduled preventive maintenance to ensure optimal system performance and longevity.
Completed annual preventive maintenance visit on a mini split air conditioning system with two indoor wall-mounted heads. Performed comprehensive tune-up inspection including thermostat function verification, filter condition assessment, blower assembly examination, outdoor coil inspection, electrical component testing, condensate drain check, and refrigerant performance evaluation. Measured temperature split across the system to verify proper cooling capacity. Inspected copper refrigerant lines and insulation for integrity, checking for signs of wear, leaks, or damage. Examined all soldered joints and brass fittings on refrigerant piping. Cleaned and evaluated air filters on both indoor heads, confirming proper airflow. All operational parameters and temperature readings were within manufacturer specifications. No mechanical defects, refrigerant leaks, electrical issues, or safety concerns identified. System operating properly at time of service completion.
Responded to no cooling complaint on 12-year-old Trane system experiencing repeated short cycling issues. Upon arrival, found condenser unit shutting down prematurely with no cooling delivered to home. Connected refrigerant manifold gauges and diagnosed system overcharge condition with pressures reading 112.2 PSIG low side and 309.7 PSIG high side, significantly above manufacturer specifications. This overcharge was causing compressor to cycle on high pressure safety, resulting in inadequate cooling and premature shutdowns observed during previous service visits. Recovered excess refrigerant from system to bring charge levels back to proper specifications per manufacturer guidelines. Monitored system operation through multiple cycles to verify stable pressures and proper compressor runtime. Unit now operating within normal parameters with appropriate cooling delivery throughout home.
Responded to no cool complaint on mini-split system installed in April of previous year. Upon arrival, unit was operating and cooling properly with supply air temperature measuring 36°F, indicating efficient operation. Investigated reported humming noise at outdoor unit and moisture accumulation on condenser fins. Performed comprehensive system testing and operational checks of both indoor and outdoor components. Verified refrigerant charge, airflow, electrical connections, and overall system performance. All components found to be functioning within normal parameters. Unit operating as designed with no deficiencies noted at time of service.
Completed follow-up phone call for recurring HVAC system issue on warranty job #243672. Confirmed thermostat needs to be ordered based on previous technician's diagnostic notes indicating either thermostat or furnace board failure. Documented Honeywell thermostat model THX321WF3001W for warranty parts ordering and scheduled return visit upon part arrival.
Completed comprehensive A/C maintenance on one Goodman condenser unit utilizing 410A refrigerant under 68-degree ambient conditions. Performed full system inspection including filter, thermostat operation, temperature differential measurement, condenser coil condition, motor operation, capacitor testing, compressor performance, refrigerant charge verification, and condensate drain functionality. Recommended 14x25x1 filter replacement for optimal airflow and contactor replacement due to wear; customer declined contactor service at this time and estimate was provided for future consideration. System operating within normal parameters and cooling effectively upon completion of maintenance service.
Responded to no cooling complaint on Mitsubishi 3.5-ton Intelliheat heat pump system with air handler and mini-split head. System was running continuously but unable to reach setpoint temperature at thermostat, while mini-split head connected to same outdoor condenser operated normally. Diagnosed communication fault between air handler control board and thermostat preventing proper system operation. Performed power cycle reset procedure on both furnace control board and Honeywell ProSeries thermostat to restore communication protocol. Verified thermostat display showed proper cooling mode and setpoint, confirmed system response to temperature adjustments, and restored normal cooling operation to air handler zone.
Replaced standard height toilet in entryway bathroom with new unit. Removed existing toilet, cleaned flange area of old wax ring and caulk residue, installed new wax ring and mounting bolts, and properly set new toilet. Performed leak testing with multiple flush cycles to verify proper seal and operation, applied caulk around base perimeter, and restored bathroom to service condition.
Completed scheduled air conditioning tune-up and maintenance inspection on 15-year-old residential cooling system as part of preventative maintenance agreement. Performed comprehensive system evaluation including electrical panel inspection and voltage testing, recording 497 volts at the disconnect. All components operating within normal parameters with no deficiencies identified; system confirmed in good working condition.
Located and diagnosed refrigerant leak in the evaporator coil of the air handler unit located in walk-in attic. Recovered contaminated refrigerant from system and removed failed evaporator coil. Installed new horizontal left evaporator coil with TXV for 410A refrigerant system. Pressure tested system to verify leak-free installation, evacuated system to proper vacuum levels, and recharged with 410A refrigerant to manufacturer specifications. Cycled system through complete operational test and verified proper cooling performance. All work completed with condenser access via ladder to balcony location.
Completed assessment of existing toilet in residential bathroom for replacement project. Unit showed signs of age and frequent clogging issues, though no active leaks or structural damage were present at time of inspection. Documented current fixture configuration including standard two-piece white ceramic toilet with round bowl in compact bathroom alcove with beige tile flooring. Provided quote for complete toilet removal and replacement with Gerber Avalanche model GAV31852, featuring round bowl design and 12-inch rough-in specification to match existing plumbing configuration. Discussed project timeline and scheduling options for prompt installation in multi-level condominium building.
Responded to no cool call on 35+ year old Glowcore air conditioning unit. Upon arrival, found system attempting to start but failing to run. Diagnostic testing revealed dual-circuit run capacitor failure affecting both condenser fan motor and compressor. Additionally discovered failed Supco hard start kit that likely remained energized longer than designed due to capacitor degradation, potentially causing internal compressor damage. Further inspection uncovered charred and corroded compressor start winding wire and contactor control wire damaged by rodent activity. Significant debris accumulation and environmental exposure evident throughout outdoor unit. Performed comprehensive electrical measurements to assess extent of damage. Due to age of equipment and multiple simultaneous component failures, discussed repair versus replacement options with homeowner. Coordinated service advisor consultation and provided detailed repair estimates via email for informed decision-making. Explai
©2026 Hurlburt. All Rights Reserved.
Privacy Policy | Terms and
Conditions | [cookie_preferences_link]
This site is protected by reCAPTCHA and the Google Privacy Policy and Google Terms of Service apply.