To get assistance with your HVAC and plumbing repairs, maintenance, and installations, look no further! To see what our satisfied customers think about our HVAC and plumber services in Plum City, WI, read our reviews below.
Hurlburt Heating & Plumbing has completed 20 jobs in Plum City, WI between October 2025 and January 2026.
The most recent job was on January 9, 2026.
Hurlburt Heating & Plumbing has completed 105 jobs in Plum City, WI in the last 12 months. The first job there was in October 2015.
Completed annual tune-up on 50-year-old boiler system as part of maintenance agreement. Inspected all components with system functioning properly, though deteriorating burner gasket was temporarily sealed with high-temperature silicone. Customer advised that while system should operate through current heating season, boiler replacement is recommended next year. One mini-split service deferred until spring due to snow accumulation; second unit to be serviced at that time.
Responded to no-heat service call for wood boiler system. Diagnosed broken impeller on existing Taco 009 circulator pump. Determined pump was oversized for application, replaced with smaller Taco 007 model to better match system requirements. Refilled boiler and verified proper operation.
Completed scheduled Family Rewards maintenance service including furnace tune-up, humidifier pad replacement (using customer-provided pad), and air exchanger cleaning and inspection. All systems thoroughly examined with no issues identified. All components functioning properly and left in good working condition.
Responded to service call for water softener inspection due to water accumulation inside unit. Also checked malfunctioning shower head located adjacent to softener and performed maintenance on nearby sediment filter system requiring cleaning. Primary contact was Ben.
Completed bi-annual maintenance service on residential furnace for reward membership customer. Performed comprehensive inspection including heat exchanger verification, burner assessment, flame sensor cleaning, and condensate system check. Unit is functioning properly with no defects observed in critical components.
Performed scheduled maintenance on 4-year-old Lennox gas furnace per maintenance agreement. Cleaned condensate drain and flame sensor, inspected heat exchanger for defects, and verified proper operation. Furnace is functioning as designed; all required maintenance completed according to program specifications.
Responded to customer report of no heat and critical alert on thermostat indicating communication failure with Smart Hub. Diagnosed issue was related to power interruption when customer shut off breaker earlier in day. Restored system functionality by cycling power to reset communication between thermostat and Smart Hub. Performed comprehensive inspection of 4-year-old Lennox furnace with no issues found. System tested multiple times in normal and test modes, confirming proper operation. Customer advised to cycle power if issue recurs and recommended routine maintenance to prevent future problems.
Diagnosed no-heat complaint on 10-year-old Crown oil boiler. Found thermostat non-responsive due to dead batteries. Replaced batteries, which restored normal system operation. Recommended boiler tune-up and scheduled follow-up visit with technician more specialized in this equipment type.
Performed boiler tune-up maintenance. Inspected heat exchanger, noting early rust accumulation that could potentially affect operation if it progresses. Vacuumed accessible bottom portion of unit. Confirmed proper igniter ohm readings and verified all radiators were functioning correctly with system pressure at approximately 12 psi. No water addition required at this time.
Responded to no-heat complaint regarding ventless heater in milk room. Diagnosed and successfully restored unit operation. Informed customer about safety concerns related to exhaust gases in enclosed space. Identified electrical junction box with corrosion/weathering. Scheduled follow-up visit with service advisor to discuss replacement options for this aging system.
Performed warranty service to replace failed condensate pump on customer's HVAC system. Diagnosed float mechanism failure in original pump and installed replacement unit to restore proper condensate drainage function.
Responded to recurring toilet clogging issue, which had previously been serviced approximately 1.5 weeks prior. Snaked the toilet to restore function and discovered deteriorated cast iron drainage pipes with significant corrosion and rust buildup as the root cause of persistent clogs. Provided customer with estimate to replace the damaged cast iron piping section.
Responded to service call for water softener system installed less than a year ago that was experiencing improper softening levels. Diagnosed improper settings in control panel parameters - adjusted hardness setting from 20 to 25 grains, increased brine fill time from 12 to 28 minutes, and reduced draw time from 60 to 54 minutes to optimize regeneration cycle and proper water treatment.
Responded to no-heat call on a Daikin propane furnace that failed to ignite after LP tank replacement. Diagnostic testing revealed clogged burners affecting proper combustion. Performed complete furnace service including cleaning of plugged burners and recommended replacement of existing burners with stainless steel alternatives to prevent future ignition failures.
Replaced universal gas valve on a natural gas furnace as previously diagnosed and quoted. After installation, verified proper manifold pressure settings and confirmed normal heating operation. Unit was returned to service and now operating correctly with the new replacement valve.
Responded to service call for smart toilet overflowing and leaking from base. Upon inspection, discovered main 4-inch drain line was completely blocked at transition to cast iron pipe. Observed significant deterioration at pipe connection point. Cut open pipe to drain standing water, then made temporary repair to restore functionality. Submitted bid for permanent repair solution due to observed corrosion and deterioration of cast iron waste pipe junction.
Responded to no-heat call for 15-year-old LP furnace with symptoms of failure to ignite and blower continuing to run. Diagnosed tripped rollout switch and observed oversized flames between burners. Extracted burners for cleaning, adjusted inter-burner spacing, and inspected heat exchanger which showed no concerning conditions. Upon reassembly and restart, furnace operated normally with proper ignition and heating cycles.
Diagnosed hot water system issue which was incorrectly attributed to faulty cartridges. Identified and confirmed a defective 1-inch check valve allowing hot water to bleed into the domestic cold water line, resulting in 107°F water entering the water softener. Measurements showed system temperatures between 125-126°F. Follow-up includes ordering replacement check valve.
Responded to recurring toilet drainage issue at Unit 12-4. Diagnosed slow tank refill (approximately 20 minutes) causing toilet clog. Replaced defective angle stop valve, restoring proper water flow and resolving drainage problem. Inspected supply line and connections for proper function after repair.
Completed replacement of deteriorated 15-year-old toilet in main floor bathroom following customer's repiping project. Removed damaged toilet and installed new Gerber Viper ADA-compliant elongated toilet with new wax ring and bolts. New fixture provides improved functionality with water-efficient operation, chemical resistance, and sanitary design features to prevent liquid intrusion under the tank.