Responded to service call for water leakage from disconnected hoses of an outdoor wood burner in the furnace room, causing flooding and potential mold issues. Assessed the situation and advised customer to seal the basement opening and install drain tile outside to properly manage water intrusion. Attempted to install whole house water filter but had incorrect size; replacement filter has been ordered and will be shipped directly to customer's residence.
Responded to emergency service call for a leaking 40-gallon water heater with stuck shut-off valve. Upon inspection, determined the unit required full replacement due to bottom leakage. Installed new water heater, connected all necessary plumbing and gas lines, and verified proper operation with no leaks present. Water service to home was successfully restored.
Replaced defective furnace burner assembly and collector box on Lennox unit. Initial shipment contained incorrect collector box, but correct parts were installed successfully. System was tested and confirmed to be operating properly. Delivered previously ordered water filter to customer at time of repair.
Replaced belt drive PSC blower motor in attic-mounted air handler. Installed new belt (up to 90 inch) along with motor and performed necessary blower repairs. Verified proper system operation after completion.
Diagnosed and resolved cold water supply issue in bathroom. Discovered leaking waterlines under the sink along with a compromised drain pipe. Repaired by reinstalling drain assembly and tightening a loose SharkBite fitting, restoring proper water flow and eliminating leaks.
Replaced malfunctioning room sensor on furnace #3 that had lost communication. Installed new Meno room sensor and successfully restored connectivity to the system. Service completed under warranty.
Diagnosed ongoing heating issues with furnace #3, finding that multiple indoor room sensors were failing to communicate with the thermostat system. Attempted reconnection of existing sensors and replacement of thermostat without success. Will return with replacement room sensors to resolve the temperature control problems affecting multiple zones.
Responded to no-heat complaint on furnace #3, which was reported as non-operational for the third service call in three weeks. Upon arrival, inspected both furnaces in the mechanical room and found furnace #3 operating normally. Monitored the unit for 20 minutes to verify proper function, checked condensate drain for blockages and confirmed filter was clean. No operational issues identified. Customer advised to report any recurrence.
Performed diagnostic evaluation on boiler system at customer's request. Observed system operation and identified possible air entrainment in the radiator circuit. Noted an existing auto air vent that could address the issue but deferred maintenance to avoid potential leakage problems. Customer elected to postpone thorough cleaning and auto vent service until spring. Also inspected water heater for reported leakage, but no active leak was detected.
Responded to service call for non-functioning air handler in attic. Diagnosed seized blower motor as evidenced by frozen shaft and inability to rotate. Removed belt and pulley assembly for further inspection. Documented extensive rust and dust accumulation on housing components. Submitted motor replacement specifications to parts department for customer estimate.
Responded to service call for heat pump communication error (Alarm 31). Inspected and re-tightened all low-voltage wiring connections from thermostat to outdoor unit. System is currently operational, but customer advised to monitor for recurrence of communication errors over the next few weeks.
Responded to service call for toilet not holding water in customer's only bathroom. Upon inspection, found 10-year-old Mansfield toilet in deteriorated condition with failing internal components. Removed old unit and installed new Gerber Viper elongated comfort height two-piece toilet, restoring proper functionality to the residence's sole bathroom facility.
Responded to service call for continuously running toilet. Diagnosed issue with failing flapper valve on Gerber Viper toilet that was sinking inside the cup. Replaced flapper valve to restore proper flushing function and eliminate water waste.
Responded to service call for furnace that wouldn't turn off. Diagnosed that the makeup air unit had been inadvertently activated, causing excessive heating in the shop. No equipment malfunction found; instructed customer that makeup air unit switch should remain in OFF position.
Responded to no-heat call for 8-12 NG furnace (6 years old). Diagnosed system shutdown due to open low pressure switches. Inspected venting and condensate lines, finding one pressure switch line plugged. Cleared obstructed pressure switch line using nitrogen. Performed preventive maintenance including heat exchanger inspection and flame sensor cleaning. System restored to proper operation after service. Recommended customer obtain estimates for collector box and burner replacement.
Responded to urgent service call for non-flushing toilet, the only one in customer's home. Diagnosed partial clog in drain line between toilet and main. Removed toilet, performed camera inspection, cleared blockage with snake, verified proper flow, then reinstalled toilet and confirmed proper operation through multiple test flushes.
Diagnosed non-flushing toilet issue by removing unit and inspecting drainage path. Identified improperly seated wax ring partially obstructing waste flow. Installed new wax ring and reset toilet, restoring proper flushing function.
Responded to emergency call for active copper pipe leak in attic area. Upon inspection, identified multiple deteriorated sections in the copper piping causing water leakage. Successfully replaced damaged section of copper piping to resolve the issue. Water quality testing performed post-repair to confirm system integrity.
Responded to no heat call for 20+ year old LP boiler system. Upon inspection, confirmed customer's report of failed blower motor and identified a suspected crack in the heat exchanger. Customer was informed that unit is at end of life and replacement is recommended rather than repair. Advisor scheduled to provide replacement options.
Performed annual maintenance on 1-year-old furnace system. Corrected filter installation issue by making adjustments to the return air drop, resolving customer's difficulty with filter replacement. Conducted complete system check with all operations verified functioning properly. Provided customer with water heater replacement options per request.