Repaired bathtub leak stemming from a broken plastic SharkBite fitting on the hot water supply line. Customer damaged the supply line while attempting to remove the spout. Resolved issue by shutting off water supply, removing the damaged fitting, and re-piping with new SharkBite fitting, pro adapter, and coupling.
Repaired bathtub leak where customer damaged hot water supply line while attempting to remove spout. Shut off water supply, removed broken plastic SharkBite fitting and re-piped with new SharkBite fitting, professional adapter, and coupling to restore proper function.
Repaired customer-damaged bathtub plumbing after hot water supply line was broken during DIY spout removal attempt. Found plastic SharkBite fitting broken in half, requiring immediate water shut-off. Removed damaged fitting and re-piped with new SharkBite fitting, pro adapter, and coupling to restore proper water flow.
Responded to no heat call for 10+ year old boiler system not operating properly. Diagnosed faulty transformer in air handler unit. Installed new air handler in attic but discovered circuit breaker would not reset. Documented electrical panel condition showing Square D breaker with connected wiring. Parts request submitted for replacement breaker to complete repair.
Performed annual maintenance on customer's reward membership heating system. Conducted 10-2 furnace tune up on Lennox heat pump system with electric air handler. Inspected and confirmed proper operation of both heat pump and electric heat components, with all systems functioning correctly.
Responded to service call for heater pilot light issues in an outbuilding. Found gas supply had been shut off; restored gas flow, relit pilot light, and verified proper operation of wall-mounted heating unit. Recommended customer maintain pilot light year-round to prevent future ignition problems.
Responded to service call for Lennox G61MP furnace with airflow issues. Inspected heat exchanger and found no defects, confirmed condensate was clear, but identified severely rusted burners requiring replacement. While heat exchanger appears unsooted despite observed flame issues and blackened exhaust pipe, provided customer with replacement options for both components.
Performed comprehensive furnace tune-up on 3-year-old FRP system, including inspection of all routine components, blower verification (clean and balanced), condensate line clearance, and heat exchanger examination with no compromises found. During testing, adjusted gas pressures (found low fire slightly elevated at 6.6 inwc, adjusted to 6inwc) and confirmed proper system operation with satisfactory 75-degree temperature rise after 15-minute operational test.
Returned to install burner assembly but discovered incorrect burners were supplied. Removed old assembly and prepared components for installation before identifying the mismatch. Will need to re-order correct burners and return to complete the previously paid repair.
Performed Family Rewards Tune-Up on 2-year-old heating system. Service included cleaning flame sensor, inspecting condensate system, and verifying proper operation of main furnace and electric boilers for basement and garage floor heating systems. Garage floor heating could not be activated due to warm ambient temperature limiting thermostat range, though system appears functional.
Replace motor and fan blade,12 year parts warranty
Went out to a residential home to clean the ducts. The ducts were very dirty, and the homeowner was worried about the air quality. I used a powerful vacuum to remove all the dirt and debris from the ducts and sanitized them. The homeowner was very pleased with the results and the improved air quality in the home.
Perform cross connection test
Perform cross connection tests
Fix furnace
Fix leak
Perform cross connection test
Perform cross connection test
Performed safeties and check and inspection on Pulse furnace for a family in Pepin.
Replaced thermostat