Responded to no heat call for 10+ year old LP furnace. Diagnosed and repaired burnt wiring connections to blower motor using new adapter connectors, restoring system operation. Noted significant cracking of burner plate and advised customer that equipment is approaching end of useful life; provided quote for replacement furnace as requested.
Completed maintenance service on Goodman forced air LP gas furnace. Performed comprehensive inspection including heat exchanger evaluation with no defects found. Cleaned flame sensor and condensate system; furnace is in good overall condition with no operational issues identified.
Responded to emergency no-heat call where customer reported smoking and flames inside their aging boiler. Investigation revealed combustion issues caused by insulation material that had been pulled into the burner orifice area by a rodent, preventing proper burning. Removed insulation debris, performed standard boiler service, and cleaned flame sensor to restore proper operation. System functioning normally upon departure but recommended replacement of pilot assembly if intermittent pilot issues persist.
Completed annual maintenance tune-up on 17-year-old high-efficiency Munchkin boiler system. Identified one leaking pipe in the hydronic distribution network requiring repair. Provided customer with requested quotes for boiler replacement, duct cleaning, and water softener installation due to aging equipment condition. Referred to comfort advisor for follow-up on upgrade options.
Performed semi-annual maintenance on Lennox heat pump system per Family Rewards agreement. Conducted complete tune-up on electric heat and heat pump components with all electrical connections testing within specifications. Replaced dirty filter, verified proper operation in both standard and emergency heat modes with acceptable temperature rises (40° and 45° respectively), and inspected indoor air handler and outdoor condensing unit with no issues found.
Performed comprehensive furnace tune-up service on residential system. Inspection revealed clean filter and proper gas pressures with temperature rise of 45 degrees. Noted blower wheel accumulating dirt with mechanical play; all electrical components including capacitor tested within specifications. Heat exchanger inspection showed no compromises. System tested and monitored for 20 minutes with normal operation. Customer informed about blower motor condition and future repair recommendations.
Responded to service call for noisy boiler with water leakage. Diagnosed and addressed three issues: leaking condensate pump, vibrating pipe, and low water level in system. Completed temporary repairs; customer has requested follow-up service for boiler cleaning and replacement of auto fill and backflow preventer.
Completed routine maintenance on IBC boiler system including disassembly, thorough cleaning of heat exchanger and flame sensor, and system flush. Verified proper operation post-service with boiler functioning optimally. Documented exterior drainage configuration with photo for service records.
Completed annual furnace tune-up on 23-year-old FRP unit for rewards member. Inspected and verified proper operation of the heat pump system including air handler, electric heat components, and outdoor condenser unit. All equipment functioning properly despite age (2002 installation). System receives limited use due to middle unit handling primary heating/cooling load for the residence.
Responded to service call for 1-year-old electric water heater leaking from bottom. Inspection revealed water actively streaming from brass valve connection on supply line with mineral buildup indicating ongoing leak. Determined tank failure requires complete replacement. Informed homeowner of warranty options through original retailer (Home Depot) as unit was not installed by our company.
Replaced damaged hose bib with new code-compliant unit due to freeze break damage on backside. Addressed pressure tank issues by installing WX203 Wall Troll pressure tank and replacing associated piping after diagnosing air leak causing pressure retention problems. Additionally installed new icemaker water supply line that was previously non-existent.
Responded to intermittent no-heat call with system locking out on 12-flash code (igniter relay failure) after 10-15 minutes of operation. Investigated system that was short cycling and failing to light. Increased fan speed and temporarily removed filter which improved operation. Inspected heat exchanger and identified cracked AC drain pan. Advised customer that control board replacement may be necessary if issue persists and provided estimate.
Responded to no heat complaint on 1-2 year old furnace. Diagnosed condensate backup causing pressure switch to disengage and prevent ignition. Cleaned condensate line to restore proper drainage. Identified exhaust pipe leaking at connection point sealed with improper black tape. Provided repair options for exhaust pipe to homeowner. System operational after service.
Responded to call regarding no hot water. Diagnosed and replaced failed zone valve for boiler system. Found system water level critically low, refilled to proper operating level. Cycled system to confirm proper operation, verified hot water restoration, and noted quieter system operation after service.
Inspected customer's water softener system following recent home purchase. Diagnosed salt bridging issue in brine tank with caked salt deposits at bottom. Observed active flow indicator light. Examined gas line components including Watts FBV-3C valve and associated copper piping connections. Provided operational guidance to new homeowner on proper system maintenance for intermittent cabin use.
Repaired bathtub leak stemming from a broken plastic SharkBite fitting on the hot water supply line. Customer damaged the supply line while attempting to remove the spout. Resolved issue by shutting off water supply, removing the damaged fitting, and re-piping with new SharkBite fitting, pro adapter, and coupling.
Repaired bathtub leak where customer damaged hot water supply line while attempting to remove spout. Shut off water supply, removed broken plastic SharkBite fitting and re-piped with new SharkBite fitting, professional adapter, and coupling to restore proper function.
Repaired customer-damaged bathtub plumbing after hot water supply line was broken during DIY spout removal attempt. Found plastic SharkBite fitting broken in half, requiring immediate water shut-off. Removed damaged fitting and re-piped with new SharkBite fitting, pro adapter, and coupling to restore proper water flow.
Responded to no heat call for 10+ year old boiler system not operating properly. Diagnosed faulty transformer in air handler unit. Installed new air handler in attic but discovered circuit breaker would not reset. Documented electrical panel condition showing Square D breaker with connected wiring. Parts request submitted for replacement breaker to complete repair.
Performed annual maintenance on customer's reward membership heating system. Conducted 10-2 furnace tune up on Lennox heat pump system with electric air handler. Inspected and confirmed proper operation of both heat pump and electric heat components, with all systems functioning correctly.